This is a libary for arduino connecting to a Soladin 600 inverter Soladin 600 en Windmaster 500 inverters from mastervolt are basicly the same Connecting to windmaster is not tested. The libary uses the softserial libary to make a connection to the Soladin, leaving the hardware serial for programming and monitoring. Libary made and tested on version 1.0 and 0.22 Hardware connection: Inside soladin 600 are two CNY17 Opto's RJ 12 Connector 1 nu socket(soladin) 6 5 4 3 2 1 2 TX - 1 2 3 4 5 6 ____________________ 3 TX + ____________________ | || || || || || || | 4 RX + | || || || || || || | | || || || || || || | 5 RX - | | | | 6 nu | | |_____frontview_____| |_____frontview____ | |_______| [______] |___| ARDUINO ____ RJ 12 connector + 5v �-----------[____]---------� 3 (TX+) 220R (soft)TX �--------------------------� 2 (TX-) ____ + 5V �----------[____]-----†----� 4 (RX+) 10K | (soft)RX �---------------------† gnd �--------------------------� 3 (RX-) Retrieved from "http://wiki.firestorm.cx/index.php/Soladin" Serial Protocol: Every packet has the following common fields: The first 4 bytes contain the packets source and destination: 0x0000: 16 bit destination address for the packet. 0x0000: 16 bit source address for the packet. 0x0000: 16 bit command ID. The master device (the computer) uses address 0x0000. In the probe command from the Windows software, the source and destination addresses are both set to 0x0000. This may indicate the packet is a broadcast packet intended for all non-master devices on the bus. All data is transmitted as big-endian (most significant byte first). 0x00: The last byte of every packet is a checksum. It is the lower 8 bits of the sum of all the previous bytes in the packet. I've included the responses to each command from my Soladin 600, address 0x0011. This appears to be the same address for all Soladin 600's. 0xC1: Probe The first packet transmitted seems to be a probe command. Note that the source and destination addresses are both set to 0x0000. TX: 00 00 00 00 C1 00 00 00 C1 RX: 00 00 11 00 C1 F3 00 00 C5 Other than the device address, the response from my Soladin 600 doesn't appear to contain any information. In cases where there are more than once device, will they all respond to this command? Can a devices address be changed? 0xB4: Firmware Information Returns version information about the firmware. TX: 11 00 00 00 B4 00 00 00 C5 RX: 00 00 11 00 B4 F3 00 00 00 00 00 00 00 E3 00 04 01 34 06 00 00 00 00 00 00 00 00 00 00 00 DA 0xE3: Firmware ID 0x0104: Firmware version (1.04) 0x0634: Firmware date 0xB6: Device Stats Returns statistics about the operation of the device. TX: 11 00 00 00 B6 00 00 00 C7 RX: 00 00 11 00 B6 F3 00 00 04 03 35 00 8A 13 F4 00 00 00 24 00 90 0B 00 1F DB BC 01 00 00 00 FD 0x06: 0x0000: Flags, normal operation in the response above 0x08: 0x0304: PV voltage * 10 = 77.2 V in the response above 0x0A: 0x0035: PV amperage * 100 = 0.53 A 0x0C: 0x138A: Grid frequency * 100 = 50.02 Hz 0x0E: 0x00F4: Grid voltage = 224 V 0x10: 0x0000: Unknown 0x12: 0x0024: Grid power output = 36 W 0x14: 0x000B90: Total grid power output * 100 = 29.60 kWh 0x17: 0x1F: Device temperature = 31 °C 0x18: 0x0001BCDB: Total operating time = 113883 minutes 0x1C: 0x0000: Unknown Flags Flags are bit mapped and represent current status of the inverter. Normal opartion of the inverter is identified with no flag being set. 0x0001: Usolar too high 0x0002: Usolar too low 0x0004: No Grid 0x0008: Uac too high 0x0010: Uac too low 0x0020: Fac too high 0x0040: Fac too low 0x0080: Temperature too high 0x0100: Hardware failure 0x0200: Starting 0x0400: Max power 0x0800: Max current 0xB9: Read Maximum Power Returns maximum output power of the inverter. TX: 11 00 00 00 B9 00 00 CA RX: 00 00 11 00 B9 F3 00 00 20 00 00 00 1B 00 21 00 22 00 00 00 E5 02 7E 48 36 00 00 00 00 00 1E 0x18: 0x0036: Maximum power = 54 W 0x97: Reset Maximum Power Resets maximum uotput power returned by command 0xB9 TX: 11 00 00 00 97 01 00 00 A9 RX: 00 00 11 00 97 01 00 00 A9 0x9A: History Data The inverter stores data (grid energy and time) for last 10 day. The inverter has no clock built-in, a day is therfore defined as operating season. TX: 11 00 00 00 9A 00 00 AB 0x05: 0x00 Day to read. 0 - today, 9 - 9 days before today RX: 00 00 11 00 9A 54 05 04 0x05: 0x54: Daily opertion time * 5 min = 420 minutes 0x06: 0x0005: Grid output * 100 = 0.05 kWh
About
Arduino libary connecting to a Soladin 600 inverter
Resources
Stars
Watchers
Forks
Releases
No releases published
Packages 0
No packages published
Languages
- C++ 100.0%