Skip to content
/ fygen Public
forked from mattwach/fygen

fygen is a Python library for Feeltech Signal Generators (FY2300, FY6600, FY6800, FY6900 and more)

License

Notifications You must be signed in to change notification settings

hankst69/fygen

 
 

Folders and files

NameName
Last commit message
Last commit date

Latest commit

 

History

10 Commits
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Repository files navigation

Table of Contents

Introduction

fygen is a library that allows you to control any of several Feeltech signal generators. It was developed with the FY2300 which is nearly identical to the FY6600, FY6800 and FY6900 in features. Other generators should also work, although some tweaks may be required.

Example

fygen has the following features:

  • Comprehensive support (custom waveforms, measurements, etc)
  • High level and low level access methods.
  • A full set of unit tests.
  • The code is lint clean (using the provided lint rules).
  • Each function was validated with a real FY2300.
  • Open source, pure Python.
  • Supports Python 2 and Python 3.
  • Supports most OSes (Linux, Windows, Mac)
  • Comprehensive usage documentation and examples are included.

You can also use it with the XY function to draw a Kitty:

Kitty

Or some pi:

PI

Disclaimer

fygen is free and open source software. I accept no responsibility or liability for any damage caused, time lost, or money lost as a result of using this software. You should test all features in a safe manner and assume responsibility for anything that might go wrong. If this is not acceptable, please do not use this software.

Prerequisites

You may use either Python 2 or Python 3.

For either, you will need the pyserial package. The process of installing this package will vary depending on your environment. Some examples:

Ubuntu + Python2:

sudo apt install python-serial

Ubuntu + Python3:

sudo apt install python3-serial

If you plan on using this library interactively, I recommend trying ipython, which can be easily installed in Ubuntu via:

sudo apt install ipython ipython3

Basic Usage

You must determine the serial port address of your connected signal generator. In Linux, /dev/ttyUSB0 is commonly correct. This is also is the default value.

import fygen
fy = fygen.FYGen('/dev/ttyUSB0', debug_level=1)
fy = fygen.FYGen(debug_level=1)  # Same thing

# In case you get UnsupportedDeviceError, you can manually specify
# one of the supported devices that may be compatible.
# The id's of waveforms are different between models,
# so you might not get the waveform you ask for
fy = fygen.FyGen(device_name='fy2300')

Once connected, this command will setup a 1Mhz sin wave on the main channel:

fy.set(
  channel=fygen.CH1,
  enable=True,
  wave='sin',
  freq_hz=1e6,
  volts=5)

All set() parameters are optional. Commands can be split arbitrarily. This sequence should have the same behavior as above:

fy.set(0, wave='sin')
fy.set(0, freq_hz=1e6)
fy.set(0, volts=5)
fy.set(0, enable=True)

For channel, you can use CH1, CH2 or just 0 and 1. You can send to multiple channels at the same time by providing a list or tuple:

fy.set(channel=(0,1), volts=3)

You can also set the default channel(s) that subsequent command will use if not given a channel parameter:

fy.default_channel=(0,1)
fy.set(volts=4)

You can use a python dict to hold settings:

ch1_settings = {
  'channel': fygen.CH1,
  'enable': True,
  'wave': 'square',
  'freq_hz': 5e5,
  'volts': 3.5
}
fy.set(**ch1_settings)

ch2_settings = dict(ch1_settings)
ch2_settings.update({'channel': fygen.CH2, 'volts': 1})
fy.set(**ch2_settings)

See more docs on set

help(fygen.FYGen.set)

Or online help:

fygen.help()

Low Level Access

The fygen library offers low level access.

If you issue the send() method, the command will be sent to the device and the response from the signal generator will be returned. Some examples:

fy = fygen.FYGen()
fy.send('WMW0')
fy.send('RMW')

You can also see the commands send by adding the debug_level option:

fy = fygen.FYGen(debug_level=1)
fy.set(wave='sin')
  WMW00

As illustrated, low-level commands sent will be output to the console. There is also a debug_level=2 option to hold off sending the commands until you press enter.

See examples/lowlevel for some code examples.

Available Waveforms

Name Description Channels Devices
sin Sin 0, 1 all
square Square 0, 1 all
cmos CMOS 0, 1 all
adj-pulse Adjustable Pulse 0 all
dc DC 0, 1 all
tri Triangle 0, 1 all
ramp Ramp 0, 1 all
neg-ramp Negative Ramp 0, 1 all
stair-tri Stairstep Triangle 0, 1 all
stair Stairstep 0, 1 all
neg-stair Negative Stairstep 0, 1 all
exp Exponential 0, 1 all
neg-exp Negative Exponential 0, 1 all
fall-exp Falling Exponential 0, 1 all
neg-fall-exp Negative Falling Exponential 0, 1 all
log Logarithm 0, 1 all
neg-log Negative Logarithm 0, 1 all
fall-log Falling Logarithm 0, 1 all
neg-fall-log Negative Falling Logarithm 0, 1 all
full-wav Full Wave 0, 1 all
neg-full-wav Negative Full Wave 0, 1 all
half-wav Half Wave 0, 1 all
neg-half-wav Negative Half Wave 0, 1 all
lorentz Lorentz Pulse 0, 1 all
multitone Multitone 0, 1 all
rand Random 0, 1 all
ecg ECG 0, 1 all
trap Trapezoidal Pulse 0, 1 all
sinc Sinc Pulse 0, 1 all
impulse Impulse 0, 1 all
gauss Gauss White Noise 0, 1 all
am AM 0, 1 all
fm FM 0, 1 all
chirp Chirp 0, 1 all
rectangle Rectangle 0, 1 fy6900
tra Trapezoid 0, 1 fy6900
arb1 Arbitrary Waveform 1 0, 1 all
arb2 Arbitrary Waveform 2 0, 1 all
arb3 Arbitrary Waveform 3 0, 1 all
arb4 Arbitrary Waveform 4 0, 1 all
arb5 Arbitrary Waveform 5 0, 1 all
arb6 Arbitrary Waveform 6 0, 1 all
arb7 Arbitrary Waveform 7 0, 1 all
arb8 Arbitrary Waveform 8 0, 1 all
arb9 Arbitrary Waveform 9 0, 1 all
arb10 Arbitrary Waveform 10 0, 1 all
arb11 Arbitrary Waveform 11 0, 1 all
arb12 Arbitrary Waveform 12 0, 1 all
arb13 Arbitrary Waveform 13 0, 1 all
arb14 Arbitrary Waveform 14 0, 1 all
arb15 Arbitrary Waveform 15 0, 1 all
arb16 Arbitrary Waveform 16 0, 1 all
arb17 Arbitrary Waveform 17 0, 1 all
arb18 Arbitrary Waveform 18 0, 1 all
arb19 Arbitrary Waveform 19 0, 1 all
arb20 Arbitrary Waveform 20 0, 1 all
arb21 Arbitrary Waveform 21 0, 1 all
arb22 Arbitrary Waveform 22 0, 1 all
arb23 Arbitrary Waveform 23 0, 1 all
arb24 Arbitrary Waveform 24 0, 1 all
arb25 Arbitrary Waveform 25 0, 1 all
arb26 Arbitrary Waveform 26 0, 1 all
arb27 Arbitrary Waveform 27 0, 1 all
arb28 Arbitrary Waveform 28 0, 1 all
arb29 Arbitrary Waveform 29 0, 1 all
arb30 Arbitrary Waveform 30 0, 1 all
arb31 Arbitrary Waveform 31 0, 1 all
arb32 Arbitrary Waveform 32 0, 1 all
arb33 Arbitrary Waveform 33 0, 1 all
arb34 Arbitrary Waveform 34 0, 1 all
arb35 Arbitrary Waveform 35 0, 1 all
arb36 Arbitrary Waveform 36 0, 1 all
arb37 Arbitrary Waveform 37 0, 1 all
arb38 Arbitrary Waveform 38 0, 1 all
arb39 Arbitrary Waveform 39 0, 1 all
arb40 Arbitrary Waveform 40 0, 1 all
arb41 Arbitrary Waveform 41 0, 1 all
arb42 Arbitrary Waveform 42 0, 1 all
arb43 Arbitrary Waveform 43 0, 1 all
arb44 Arbitrary Waveform 44 0, 1 all
arb45 Arbitrary Waveform 45 0, 1 all
arb46 Arbitrary Waveform 46 0, 1 all
arb47 Arbitrary Waveform 47 0, 1 all
arb48 Arbitrary Waveform 48 0, 1 all
arb49 Arbitrary Waveform 49 0, 1 all
arb50 Arbitrary Waveform 50 0, 1 all
arb51 Arbitrary Waveform 51 0, 1 all
arb52 Arbitrary Waveform 52 0, 1 all
arb53 Arbitrary Waveform 53 0, 1 all
arb54 Arbitrary Waveform 54 0, 1 all
arb55 Arbitrary Waveform 55 0, 1 all
arb56 Arbitrary Waveform 56 0, 1 all
arb57 Arbitrary Waveform 57 0, 1 all
arb58 Arbitrary Waveform 58 0, 1 all
arb59 Arbitrary Waveform 59 0, 1 all
arb60 Arbitrary Waveform 60 0, 1 all
arb61 Arbitrary Waveform 61 0, 1 all
arb62 Arbitrary Waveform 62 0, 1 all
arb63 Arbitrary Waveform 63 0, 1 all
arb64 Arbitrary Waveform 64 0, 1 all

Custom Waveforms

You can use the set_waveform() method to generate custom waveforms for your signal generator. This is done by creating an array of either floating point values or integers. The array size must match the number of data points expected by your signal generator. For the FY2300, that's 8192 values. If your signal generator expects a different number of values, use the value_count parameter to change the array size check.

Dove

Note: You can not change a waveform that is currently in-use. Trying to reconfigure a selected wave will result in the signal generator generating a corrupted waveform. The set_waveform() method checks for this and returns an error if the wave is currently selected.

Here is an example that generates a simple sin wave. Not exciting, but hopefully understandable:

import math  # if needed
fy = fygen.FYGen()
wave_data = [math.sin(t * math.pi * 2.0 / 8192.0) for t in range(8192)]
fy.set_waveform(1, values=wave_data)
fy.set(0, wave='arb1')

Here, we use the same data but change the min and max values from their default values (of -1 and 1)

fy.set_waveform(2, values=wave_data, min_value=-2, max_value=1)
fy.set(0, wave='arb2')

The effect is that the wave data is shifted up.

Finally, we create the same sin wave again, but with raw values (assuming the generator takes 14-bit values for input)

convert = lambda x: int((x + 1.0) * 8191.999)
raw_wave_data = [convert(v) for v in wave_data]
fy.set_waveform(1, raw_values=raw_wave_data)
fy.set(0, wave='arb1')

See examples/arb/simple_arb.py, examples/arb/xy_star_plot.py and examples/gcode/xy_gcode_plot.py for more examples.

Modulation

fygen supports the modulation mode of the function generator. One good way to learn it is to experiment with the functions, and look at the example scripts in examples/modulation.

Here is an example of a basic burst setup:

fy.set(channel=0, wave='sin', freq_hz=1000000, enable=True)
fy.set(channel=1, wave='square', freq_hz=100000)
fy.set_modulation(fygen.MODULATION_BURST, fygen.TRIGGER_CH2, 3)

Modulation Screen

The first line sets up a sin wave on the main channel and enables it.

The second line sets up a square wave on the secondary channel at 1/10th the frequency and does not enable it - the channel does not need to be enabled to act as a trigger.

The third line sets up the burst function, where each pulse on the secondary channel will cause 3 pulses on the primary channel to be sent. Neat!

Use help(fygen.FYGen.set_modulation) for more details on the various available options.

Sweep

fygen supports the sweep mode of the function generator. Unfortunately, on the test device (FY2300, V2.3) the sweep device firmware was buggy. It's still somewhat usable but basic functions, like enabling the sweep programatically, do not work correctly. See below for more details.

You can choose between several parameters to sweep but can only sweep one parameter at a time. The parameters you can choose are SWEEP_FREQUENCY, SWEEP_AMPLITUDE, SWEEP_OFFSET, and SWEEP_DUTY_CYCLE.

Here is an example that sweeps between 1Kz and 10Khz over a 10 second time period:

fy.set(channel=0, wave='sin', freq_hz=1000, enable=True)
fy.set_sweep(
  mode=fygen.SWEEP_FREQUENCY,
  start_freq_hz=1000,
  end_freq_hz=10000,
  time_seconds=10)

Sweep Example

You'll need to press the adjust button to start the sweep due to a firmware bug that was discovered during testing. If you believe your unit is not affected, you can issue.

fy.force_sweep_enable=True

and then the enable function can be sent to the generator.

fy.set_sweep(enable=True)

Some additional notes:

  • Changing sweep parameters during a sweep is not supported by the function generator. If you try to set any, the sweep will automatically be stopped.
  • The start_offset_volts and end_offset_volts parameters have a firmware bug work-around that adds 10 volts. Verify the final values on your function generator before enabling the sweep!

Use help(fygen.FYGen.set_sweep) for more details on the various available options. Check the examples/sweep directory for example scripts.

Measurement

The FY2300 (and similar) signal generators have the ability to measure frequencies, basic waveform timings and count pulses. Unfortunately, the utility of this feature is limited by the hardware's 5V maximum input rating. In some cases (or with a little ingenuity), it can still be a useful function.

The commands to control and get measurements are set_measurement() and get_measurement().

The first time you call:

fy.get_measurement()

The UI switches to measurement mode and you'll get bogus values returned. So discard the first call and wait the gate time to take a measurement (set to one second by default). Now you can use:

fy.get_measurement()

Measurement

to get all measurements except for the counter. The counter must be collected separate from frequency because getting the frequency resets the counter to zero. Here is an example that uses the counter:

import time  # if needed
fy.get_measurement('counter')  # enter counter mode
fy.set_measurement(reset_counter=True)
time.sleep(10)
print(str(fy.get_measurement('counter')) + ' pulses in 10 seconds')

You can pass any measurement parameter name to get just that measurement. You can alternately pass a list or set of paramaters to get multiple values:

fy.get_measurement(('freq_hz', 'duty_cycle'))

About Gate Time: set_measurement() allows you to change the gate time between 1, 10 and 100 seconds. The gate time determines the averaging window for the measurements. When changing the gate time, you need to sleep or find something else for the code to do for that many seconds as values read early will be bogus.

import time  # if needed
fy.set_measurement(gate_time=fygen.GATE_TIME_10S)
time.sleep(10)
fy.get_measurement()

Use help(fygen.FYGen.set_measurement) and help(fygen.FYGen.get_measurement) for more details on the various available options.

See the examples/measurement direectory for code examples.

Parameter Load and Save

The Feeltech signal generators offer the ability to save their current state, including the selected wave, frequency, etc in an internal storage slot.

To do so, use the save command, for example:

fy.save(2)

Save

Then to load it later:

fy.load(2)

Load

Note that slot 1 is documented to be the device's power-on state.

Parameter Synchronization

The feeltech signal generator offers the ability to synchronize one or more parameters between it's two output channels. Although this seems of limited value in scripts, it may be useful for setting up the device UI for running a test. There are 5 parameters to choose from and any combination can be active at the same time:

duty_cycle
freq
offset_volts
volts
wave

Here is an example that synchronizes frequency and amplitude:

fy.set_synchronization(freq=True, volts=True)

Synchronization

You can also get the current state of a synchronization parameter:

fy.get_synchronization('volts')

Or multiple parameters:

fy.get_synchronization(['duty_cycle', 'volts'])

Or all parameters:

fy.get_synchronization()

See help(fygen.FYGen.get_synchronization) and help(fygen.FYGen.set_synchronization) for more information.

Uplink Mode

It's possible to link several Feeltech signal generators together.

There are two commands, set_uplink() and get_uplink().

set_uplink() can turn uplink on or off and set the unit as a master or a slave. Both parameters are optional if you only want to change one. Here is an example:

fy.set_uplink(is_master=True, enable=True)

Uplink

You can also get a parameter:

fy.get_uplink('enable')

or all parameters:

fy.get_uplink()

Miscellaneous Functions

set_buzzer(True/False) can be used to turn the signal buzzer on and off. There is also a get_buzzer() method.

get_id() and get_model() can be used to get the is and model of the signal generator in use.

fygen.get_version() will tell you the version of the fygen library itself.

Read-Before-Write

By default, when you create a FYGen object, the read_before_write property is set. When this property is enabled, the signal general will be queried for it's current state before changing anything and queried again after changing the state. This is done because reading the state is much faster than writing it, thus quite a bit of time can be saved.

If the state is already as-desired, the set is skipped. If the state didn't change after a write (which sometimes can happen), the command is retried.

Here is an example for clarity.

Say the signal generator is currently set to generate sin waves.

If you type.

fy = FYGen()
fy.set(0, wave='square')

The commands sent will include the following:

RMW  -> 0
WMW01
RMW  -> 1

RMW says that the current wave selected is 0, a sin wave. WMW01 changes the wave to a square wave. Finally RMW is issued again to assert that the signal general changed the wave and didn't drop the command.

If you again issue:

fy.set(0, wave='square')

The following will occur:

RMW -> 1

and no write. This command sequence will also complete nearly instantly, verses the 250ms or so needed to issue the write.

Initial State

By default, when you create a FYGen object, the init_state property is set. When enabled, the first (and only the first) call to set() for a particular channel will attempt to set all omitted parameters (voltage, frequency, offset) to a reference value, currently defined in the code as:

SET_INIT_STATE = {
    'enable': False,
    'wave': 'sin',
    'freq_hz': 10000,
    'volts': 5,
    'offset_volts': 0,
    'phase_degrees': 0,
    'duty_cycle': 0.5,
}

To clarify, say you your very first call is:

fy = fygen.FYGen()
fy.set(0, wave='square', freq_hz=100, enable=True)

The set call actually sent will be:

fy.set(0, wave='square', freq_hz=100, enable=True, volts=5, offset_volts=0,
       phase_degrees=0, duty_cycle=0.5)

any set() calls after the first will not fill in these extra values, only the first one does this and only if init_state is left at the default value of True when initializing the FYGen object.

This is done to make the environment more consistent and tests more repeatable,

Streaming Output to a File

Instead of writing to a real signal generator, you can opt to write to a file object instead. This includes std.stdout if you want to see commands streamed to the console.

fy = fygen.FYGen(port=sys.stdout)
fy.set(0, wave='square', freq_hz=5000, volts=3, enable=True)

WMW01
WMF00005000000000
WMA3.00
WMN1

If you want to see the command that are also sent to a real device, you can use the debug_level option to do so. Refer to the troubleshooting section for more details.

Troubleshooting

With the multitude of devices and firmware releases in the wild, it's likely that some users will need to do some troubleshooting. fygen provides special modes to help investigate issues.

Problems loading the module

If you see an error like:

ImportError: No module named serial

then you'll need to install the pyserial module. See Prerequisites for more information.

Problems opening the device:

SerialException: could not open port /dev/ttyUSB0

This can happen if you are not running Linux, or you have other devices plugged in. On the mac, the serial ports have the form /dev/cu.usbserial. In windows, the serial ports have the form COM1. On mac and in windows you will also need the proper drivers installed to talk with the device.

Unexpected/Erratic device behavior

Start with the basics

fy = fygen.FYGen()  # Set serial_port, if needed
fy.send('WMW00')
fy.send('WMW01')

See if the UI on the generator responds. If so, you have basic operations working.

The next thing to try is to turn on debug mode.

fy = fygen.FYGen(debug_level=2)
fy.set(enable=True)

This will show you the commands and ask you to type enter before each one is sent. The idea is that you can track down the specific command that is not working as-expected. You can alternately use debug_level=1 to print commands to stdout without waiting for confirmation.

You can alternatively create a device that sends to stdout, take note of the codes, then use the send() to manually forward the output yourself.

fy = fygen.FYGen(port=sys.stdout)

Development

To develop in fygen you will need the pylint tools installed for Python 3.

After that, you can type

make all

To run the following:

  • Unit tests (fygen_test.py)
  • examples/ dry runs
  • Lint

These can also be run individually. Please read the short Makefile for details.

Below is a list of files and what they are for:

  • fygen.py is the main logic where most meaningful changes go.
  • fygen_test.py is a unit test for fygen.py that attempts to cover every possible error path along with example "good path" tests for each feature.
  • fygen_help.py is used to generate online help and used as a basis for generating README.md
  • make_readme.py generates README.md from fygen_help.py
  • wavedef.py contains the logic to translate between waveform names and id numbers.

For a code patch to qualify for submission:

  • The code needs to be tested in fygen_test.py
  • If needed, documentation should be added to fygen_help.py and make_readme.py should be run to regenerate README.md
  • make all should pass all unit tests and report no lint errors.

About

fygen is a Python library for Feeltech Signal Generators (FY2300, FY6600, FY6800, FY6900 and more)

Resources

License

Stars

Watchers

Forks

Releases

No releases published

Packages

No packages published

Languages

  • Python 99.4%
  • Makefile 0.6%