Insteon: Track the Status of Momentary Relay in IOLinc #356

Merged
merged 1 commit into from
Jan 17, 2014
Merged
Changes from all commits
Commits
File filter

Filter by extension

Filter by extension

Conversations
Failed to load comments.
Loading
Jump to
Jump to file
Failed to load files.
Loading
Diff view
Diff view
90 changes: 72 additions & 18 deletions lib/Insteon/IOLinc.pm
Original file line number Diff line number Diff line change
Expand Up @@ -73,11 +73,14 @@ uses a different set of commands and this code will offer only limited, if any
support at all, for EZIO devices.

The state that the relay is in when the device is linked to the PLM matters if
you are using relay mode Momentary_A.
you are using relay mode Momentary_A (I think).

=head2 BUGS

The relay state will not be accurate if you are using a momentary mode.
The implementation of Momentary_A needs work. It can be properly set on the
device, however it isn't clear how the preference for ON of OFF is selected.
This is likely done in D1-D3 in the responder link. Setting the link to OFF
in the definition may be enough to make it work, I don't yet know.

=head2 INHERITS

Expand Down Expand Up @@ -134,7 +137,9 @@ sub new
my $self = new Insteon::BaseDevice($p_deviceid, $p_interface);
$$self{operating_flags} = \%operating_flags;
bless $self, $class;
$self->restore_data('momentary_time');
$self->restore_data('momentary_time', 'relay_mode');
$$self{momentary_time} = 20 unless defined($$self{momentary_time});
$$self{relay_mode} = 'latching' unless defined($$self{relay_mode});
$$self{momentary_timer} = new Timer;
return $self;
}
Expand All @@ -159,6 +164,7 @@ sub set
($curr_milli - $$self{child_set_milliseconds} < $window)) {
::print_log("[Insteon::IOLinc] Received duplicate ". $self->get_object_name
. " sensor " . $p_state . " message, ignoring.") if $self->debuglevel(1, 'insteon');
$self->dupe_count_log(1) if $self->can('dupe_count_log');
}
else {
::print_log("[Insteon::IOLinc] Received ". $self->get_object_name
Expand Down Expand Up @@ -231,11 +237,21 @@ sub _is_info_request
$output .= ($flags & 0x40) ? "Trigger Reverse: On; " : "Trigger Reverse: Off; ";
if (!($flags & 0x08)){
$output .= "Latching: On.";
$$self{relay_mode} = 'latching';
} else {
my $momentary_state = '';
$momentary_state .= "Momentary_B: On." if $flags & 0x10;
$momentary_state .= "Momentary_C: On." if $flags & 0x80;
$momentary_state .= "Momentary_A: On." if $momentary_state eq '';
if ($flags & 0x10){
$$self{relay_mode} = 'momentary_b';
$momentary_state .= "Momentary_B: On."
}
elsif ($flags & 0x80){
$$self{relay_mode} = 'momentary_c';
$momentary_state .= "Momentary_C: On."
}
else {
$$self{relay_mode} = 'momentary_a';
$momentary_state .= "Momentary_A: On."
}
$output .= $momentary_state;
}
::print_log("[Insteon::IOLinc] Device Settings are: $output");
Expand Down Expand Up @@ -276,10 +292,11 @@ sub _process_message {
elsif ($msg{command} eq "extended_set_get" && $msg{is_extended}) {
if (substr($msg{extra},0,6) eq "000101") {
$self->default_hop_count($msg{maxhops}-$msg{hopsleft});
#D4 = Time;
#D4 = Time;
$$self{momentary_time} = hex(substr($msg{extra}, 8, 2));
main::print_log("[Insteon::IOLinc] The Momentary Time Setting ".
"on device ". $self->get_object_name . " is set to: ".
hex(substr($msg{extra}, 8, 2)) . " tenths of a second.");
$$self{momentary_time} . " tenths of a second.");
$clear_message = 1;
$self->_process_command_stack(%msg);
} else {
Expand All @@ -299,25 +316,53 @@ sub _process_message {
return $clear_message;
}

=item C<is_acknowledged([ack])>

Hijacks the routine in BaseObject. This is used to set a timer to revert the
relay state if a momentary state is used.

=cut

sub is_acknowledged
{
my ($self, $p_ack) = @_;
if (defined $p_ack && $p_ack && defined $$self{pending_state}
&& $$self{relay_mode} ne 'latching') {
#We are in a momentary mode, set a timer to reset the relay after the
#defined momentary time. This seems preferable over using set_with_timer
#as this will only trigger if the device actually acknowledges the
#state change
my $object_name = $self->get_object_name();
my $action = $object_name .'->set_receive(OFF,'.$object_name.')';
#While the IOLinc can do momentary times down to .2 seconds, the timer
#module can only do 1 second increments. I figure this slight
#difference is trivial.
my $time = int(($$self{momentary_time}/10) + 0.5);
$time = 1 unless ($time >= 1);
$$self{momentary_timer}->set($time,$action);
::print_log("[Insteon::IOLinc] Relay in momentary mode, resetting state "
. "of $object_name to OFF in $time second(s)") if $self->debuglevel(1, 'insteon');
}
return $self->SUPER::is_acknowledged($p_ack);
}

=item C<set_momentary_time(time)>

$time in tenths of seconds (deciseconds) is the length of time the relay will close when
a Momentary mode is is selected in C<set_relay_mode>.

Default 20
Acceptable Values for time: [2-255]

Default: 20 (2 Seconds)

=cut

sub set_momentary_time
{
my ($self, $momentary_time) = @_;
my $root = $self->get_root();
if ($momentary_time == 0){
::print_log("[Insteon::IOLinc] Setting " . $self->get_object_name .
" to Latching Relay Mode." ) if $self->debuglevel(1, 'insteon');
}
elsif ($momentary_time <= 255) {
$momentary_time = 2 if $momentary_time == 1; #Can't set to 1
if ($momentary_time <= 255) {
$momentary_time = 2 if $momentary_time <= 1; #Can't set to 1 or 0
::print_log("[Insteon::IOLinc] Setting Momentary Time to $momentary_time " .
"tenths of a second for " . $self->get_object_name) if $self->debuglevel(1, 'insteon');
}
Expand All @@ -339,7 +384,9 @@ sub set_momentary_time

=item C<get_momentary_time()>

Prints the device's current momentary time setting to the log.
Prints the device's current momentary time setting to the log. And stores it in
memory so that MH can reset the state of the relay after the appropriate amount
of time

=cut

Expand Down Expand Up @@ -404,7 +451,11 @@ Latching: The relay will remain open or closed until another command is received
Momentary time is ignored.

Momentary_A: The relay will close momentarily. If it is Linked while On it will
respond to On. If it is Linked while Off it will respond to Off.
respond to On. If it is Linked while Off it will respond to Off. (This setting
is likely not implemented properly by MH, if you need this setting you will have
to be a guinea pig and test it out for us. Questions: Can this be achieved by
defining links as off? When this is used, how does the IOLinc respond to direct
ON and OFF commands rather than All-Link Commands?)

Momentary_B: Both - On and Off both cause the relay to close momentarily.

Expand All @@ -424,23 +475,26 @@ sub set_relay_mode
$parent->set_operating_flag('momentary_a_off');
$parent->set_operating_flag('momentary_b_off');
$parent->set_operating_flag('momentary_c_off');
$$self{momentary_time} = 0;
$$self{relay_mode} = 'latching';
}
#Momentary A must be on for any Momentary setting
elsif (lc($relay_mode) eq 'momentary_a'){
$parent->set_operating_flag('momentary_b_off');
$parent->set_operating_flag('momentary_c_off');
$parent->set_operating_flag('momentary_a_on');
$$self{relay_mode} = 'momentary_a';
}
elsif (lc($relay_mode) eq 'momentary_b'){
$parent->set_operating_flag('momentary_a_on');
$parent->set_operating_flag('momentary_c_off');
$parent->set_operating_flag('momentary_b_on');
$$self{relay_mode} = 'momentary_b';
}
elsif (lc($relay_mode) eq 'momentary_c'){
$parent->set_operating_flag('momentary_a_on');
$parent->set_operating_flag('momentary_b_off');
$parent->set_operating_flag('momentary_c_on');
$$self{relay_mode} = 'momentary_c';
}
return;
}