Release 24.0516
Several new features and a minor fix
- Flarm alarm display time after alarm went off made configurable under FLARM->Alarm Time (new feature)
- Second option for electronic compensation (PRESSURE) using just pressures like TEK probes do (experimental new feature)
- Optimize temperature reading from TE/Baro sensors (enhancement, performance)
- Add optional logging for all sensors raw data together with timestamp under System->Logging (new feature)
- Split sensor reading and calculation of secondary data for better time correlation (enhancement)
- More constant blinking of flap lever (using realtime clock ms) (improvement)
- Added "Monitor" in "RS232 Interface S1" and S2 menu for direct access (enhancement)
- Fix polar for LAK12 that was a bit too optimistic at 180 km/h (fix of polar data)
Latest online handbook update is here: https://xcvario.com/docs-category/vario/