-
-
Notifications
You must be signed in to change notification settings - Fork 132
3.2. HTTP client
The HTTP port (see --httpport) of ebusd serves static files from the configured directory (see --httppath) as well as dynamic data from the message definitions.
The base URL for the data part is "/data
" and may be extended by the following path segments for filtering the corresponding data:
- circuit name
- message name
The data URL path understood thus "/data[/[circuit][/[name]]]
" where parts in brackets are optional.
In addition to these path components, the following query parameters are accepted:
-
since=seconds
: limit to messages that have changed since the specified UTC seconds -
poll=prio
: set the poll priority of matching message(s) to prio -
exact[=true]
: exact search for circuit/message name -
verbose[=true]
: include comments and field units -
indexed[=true]
: return field indexes instead of names -
numeric[=true]
: return numeric values of value list entries -
valuename[=true]
: include value and name of value list entries -
full[=true]
: include all available attributes -
required[=true]
: retrieve the data from the bus if not yet cached -
maxage[=seconds]
: retrieve the data from the bus if cached value is older than specified seconds (or not present at all) -
write[=true]
: include write messages in addition to read -
raw[=true]
: include the raw master/slave symbols as int arrays -
def[=true]
: include message/field definition (qq, id, fielddefs) -
define=DEFINITION
: (re-)define the message from DEFINITION (in CSV format) -
user=USER
: authenticate with USER name -
secret=SECRET
: authenticate with user SECRET
Here is an example verbose query for all messages in the mixer circuit "mc" that were changed since Sunday, January 8th 2017, 4:40 PM (CET) when the HTTP port was set to 8080:
http://localhost:8080/data/mc?verbose&since=1483890000&exact
The response to such a URL is a JSON object with a "global" property as well as an own property for each circuit matching the request path. Each property is again a JSON object with key-value pairs and for each circuit it contains the list of named messages.
The "global" property is included in every response and contains the following keys (besides others):
-
"signal"
: true or false depending on the eBUS signal state -
"lastup"
: the time in UTC seconds of the last received update for all matched messages
Here is an excerpt of an answer to the query above:
{
"mc": {
"messages": {
"CfgHeatSinkType": {
"name": "CfgHeatSinkType",
"passive": false,
"write": false,
"lastup": 1498281188,
"zz": 80,
"fields": {
"type": {"value": "mixer"}
}
},
"DateTime": {
"name": "DateTime",
"passive": false,
"write": false,
"lastup": 1498981415,
"zz": 80,
"fields": {
"state": {"value": "valid"},
"time": {"value": "09:43:37"},
"date": {"value": "02.07.2017"},
"temp": {"value": 14.750}
}
}
}
},
"global": {
"version": "3.0pre.9420946",
"updatecheck": "OK, 1 newer configuration files available",
"signal": true,
"symbolrate": 22,
"maxsymbolrate": 191,
"qq": 49,
"reconnects": 2,
"masters": 5,
"messages": 893,
"lastup": 1498981441
}
}
A comprehensive description of this API is available on SwaggerHub and in the repository.