Request for Hex Dump #2
Comments
Hi Max!
It has been a LOOOONG time haha.
I entertained this project years ago, and no longer work for that company.
However, I managed to dig up some of my old research, have a look at the
attached EXCEL sheet.
I think the information you're looking for is on sheet "Instruction Set".
You are correct, when you first connect to the UPS it performs a MASSIVE
memory dump, and you get all that information from that initial transaction.
I think it completes its scan when it reaches memory location 7F (HEX).
I have noticed that the location of the data doesn't always reside in the
same address ID's, depending on the version of the firmware, the whole
memory map shifts up or down.
Kind regards,
Ed
…On Tue, Jan 9, 2024 at 12:41 AM Max ***@***.***> wrote:
Hello!
I've done some more reverse engineering into the MicroLink protocol.
It seems like the first pages that are recieved from the UPS are a
description of the data types and the data available for a specific UPS
model.
I'm wondering if you have a hex dump of the pages from your UPS so I could
look at it to try to figure out which types are what.
Thanks!
Max
—
Reply to this email directly, view it on GitHub
<#2>, or unsubscribe
<https://github.com/notifications/unsubscribe-auth/AM3JP3Z6CH2ZPQQGSWSXZJLYNTJ7XAVCNFSM6AAAAABBSQ7DLOVHI2DSMVQWIX3LMV43ASLTON2WKOZSGA3TCNRWGU4DENA>
.
You are receiving this because you are subscribed to this thread.Message
ID: ***@***.***>
|
Hi Max (and Ed), I still have the logged serial output in my backups. I will dig them out in the next days. Kind regards |
Attached is the recorded serial communication between the UPS and APC Powerchute: |
@Neon27 can you attach it via github, seems like it got lost via email |
Sign up for free
to join this conversation on GitHub.
Already have an account?
Sign in to comment
Hello!
I've done some more reverse engineering into the MicroLink protocol.
It seems like the first pages that are recieved from the UPS are a description of the data types and the data available for a specific UPS model.
I'm wondering if you have a hex dump of the pages from your UPS so I could look at it to try to figure out which types are what.
Thanks!
Max