Notifications
You must be signed in to change notification settings - Fork 99
New issue
Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.
By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.
Already on GitHub? Sign in to your account
Value-initialize result of MaxLoc
reduction to avoid maybe uninitialized warning
#1383
Conversation
Status Flag 'Pre-Test Inspection' - - This Pull Request Requires Inspection... The code must be inspected by a member of the Team before Testing/Merging |
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
Thanks for the fix
Status Flag 'Pre-Test Inspection' - SUCCESS: The last commit to this Pull Request has been INSPECTED by label AT: PRE-TEST INSPECTED! Autotester is Removing Label; This inspection will remain valid until a new commit to source branch is performed. |
Status Flag 'Pull Request AutoTester' - Testing Jenkins Projects: Pull Request Auto Testing STARTING (click to expand)Build InformationTest Name: KokkosKernels_PullRequest_Tpls_CUDA9_Tpls_CUDA10_Tpls_CUDA10_LayoutRight_GCC720_Light_GCC720_GCC740
Jenkins Parameters
Build InformationTest Name: KokkosKernels_PullRequest_GCC720
Jenkins Parameters
Build InformationTest Name: KokkosKernels_PullRequest_GCC720_Light_LayoutRight
Jenkins Parameters
Build InformationTest Name: KokkosKernels_PullRequest_Tpls_GCC720
Jenkins Parameters
Build InformationTest Name: KokkosKernels_PullRequest_Tpls_INTEL18
Jenkins Parameters
Build InformationTest Name: KokkosKernels_PullRequest_CLANG1001
Jenkins Parameters
Using Repos:
Pull Request Author: dalg24 |
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
I figured this would be the immediate fix.
I'm quite curious why the compiler thinks this might not be initialized, though. Possibly just a quirk of it always being passed by reference, and never assigned.
Thanks @dalg24 @PhilMiller ! |
Status Flag 'Pull Request AutoTester' - Jenkins Testing: all Jobs PASSED Pull Request Auto Testing has PASSED (click to expand)Build InformationTest Name: KokkosKernels_PullRequest_Tpls_CUDA9_Tpls_CUDA10_Tpls_CUDA10_LayoutRight_GCC720_Light_GCC720_GCC740
Jenkins Parameters
Build InformationTest Name: KokkosKernels_PullRequest_GCC720
Jenkins Parameters
Build InformationTest Name: KokkosKernels_PullRequest_GCC720_Light_LayoutRight
Jenkins Parameters
Build InformationTest Name: KokkosKernels_PullRequest_Tpls_GCC720
Jenkins Parameters
Build InformationTest Name: KokkosKernels_PullRequest_Tpls_INTEL18
Jenkins Parameters
Build InformationTest Name: KokkosKernels_PullRequest_CLANG1001
Jenkins Parameters
|
Status Flag 'Pre-Merge Inspection' - SUCCESS: The last commit to this Pull Request has been INSPECTED AND APPROVED by [ PhilMiller lucbv ]! |
Status Flag 'Pull Request AutoTester' - Pull Request MUST BE MERGED MANUALLY BY Project Team - This Repo does not support Automerge |
Tentative fix for kokkos/kokkos#4959
Value-initialization will zero-initialize the
ValLocScalar
data members.To be honest I don't quite see how the warning was not there before and how it is related to the "volatile" changes in Kokkos.
cc @PhilMiller