-
Notifications
You must be signed in to change notification settings - Fork 27
Commit
This commit does not belong to any branch on this repository, and may belong to a fork outside of the repository.
- Loading branch information
Showing
2 changed files
with
185 additions
and
1 deletion.
There are no files selected for viewing
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,183 @@ | ||
/* | ||
MIT License | ||
Copyright (c) 2022 lewis he | ||
Permission is hereby granted, free of charge, to any person obtaining a copy | ||
of this software and associated documentation files (the "Software"), to deal | ||
in the Software without restriction, including without limitation the rights | ||
to use, copy, modify, merge, publish, distribute, sublicense, and/or sell | ||
copies of the Software, and to permit persons to whom the Software is | ||
furnished to do so, subject to the following conditions: | ||
The above copyright notice and this permission notice shall be included in all | ||
copies or substantial portions of the Software. | ||
THE SOFTWARE IS PROVIDED "AS IS", WITHOUT WARRANTY OF ANY KIND, EXPRESS OR | ||
IMPLIED, INCLUDING BUT NOT LIMITED TO THE WARRANTIES OF MERCHANTABILITY, | ||
FITNESS FOR A PARTICULAR PURPOSE AND NONINFRINGEMENT. IN NO EVENT SHALL THE | ||
AUTHORS OR COPYRIGHT HOLDERS BE LIABLE FOR ANY CLAIM, DAMAGES OR OTHER | ||
LIABILITY, WHETHER IN AN ACTION OF CONTRACT, TORT OR OTHERWISE, ARISING FROM, | ||
OUT OF OR IN CONNECTION WITH THE SOFTWARE OR THE USE OR OTHER DEALINGS IN THE | ||
SOFTWARE. | ||
*/ | ||
|
||
/* | ||
! WARN: | ||
Please do not run the example without knowing the external load voltage of the PMU, | ||
it may burn your external load, please check the voltage setting before running the example, | ||
if there is any loss, please bear it by yourself | ||
*/ | ||
#ifndef XPOWERS_NO_ERROR | ||
#error "Running this example is known to not damage the device! Please go and uncomment this!" | ||
#endif | ||
// Defined using AXP2102 | ||
#define XPOWERS_CHIP_AXP2101 | ||
|
||
#include <Wire.h> | ||
#include <Arduino.h> | ||
#include "XPowersLib.h" | ||
|
||
#ifndef CONFIG_PMU_SDA | ||
#define CONFIG_PMU_SDA 15 | ||
#endif | ||
|
||
#ifndef CONFIG_PMU_SCL | ||
#define CONFIG_PMU_SCL 7 | ||
#endif | ||
|
||
#ifndef CONFIG_PMU_IRQ | ||
#define CONFIG_PMU_IRQ 6 | ||
#endif | ||
|
||
XPowersPMU PMU; | ||
|
||
const uint8_t i2c_sda = CONFIG_PMU_SDA; | ||
const uint8_t i2c_scl = CONFIG_PMU_SCL; | ||
const uint8_t pmu_irq_pin = CONFIG_PMU_IRQ; | ||
bool pmu_flag = false; | ||
bool adc_switch = false; | ||
|
||
void setFlag(void) | ||
{ | ||
pmu_flag = true; | ||
} | ||
|
||
|
||
void adcOn() | ||
{ | ||
PMU.enableTemperatureMeasure(); | ||
// Enable internal ADC detection | ||
PMU.enableBattDetection(); | ||
PMU.enableVbusVoltageMeasure(); | ||
PMU.enableBattVoltageMeasure(); | ||
PMU.enableSystemVoltageMeasure(); | ||
} | ||
|
||
void adcOff() | ||
{ | ||
PMU.disableTemperatureMeasure(); | ||
// Enable internal ADC detection | ||
PMU.disableBattDetection(); | ||
PMU.disableVbusVoltageMeasure(); | ||
PMU.disableBattVoltageMeasure(); | ||
PMU.disableSystemVoltageMeasure(); | ||
} | ||
|
||
void setup() | ||
{ | ||
Serial.begin(115200); | ||
|
||
bool result = PMU.begin(Wire, AXP2101_SLAVE_ADDRESS, i2c_sda, i2c_scl); | ||
|
||
if (result == false) { | ||
Serial.println("PMU is not online..."); while (1)delay(50); | ||
} | ||
|
||
// Force add pull-up | ||
pinMode(pmu_irq_pin, INPUT_PULLUP); | ||
attachInterrupt(pmu_irq_pin, setFlag, FALLING); | ||
|
||
PMU.disableIRQ(XPOWERS_AXP2101_ALL_IRQ); | ||
// Clear all interrupt flags | ||
PMU.clearIrqStatus(); | ||
// Enable the required interrupt function | ||
PMU.enableIRQ( | ||
XPOWERS_AXP2101_PKEY_SHORT_IRQ //POWER KEY | ||
); | ||
|
||
/* | ||
The default setting is CHGLED is automatically controlled by the PMU. | ||
- XPOWERS_CHG_LED_OFF, | ||
- XPOWERS_CHG_LED_BLINK_1HZ, | ||
- XPOWERS_CHG_LED_BLINK_4HZ, | ||
- XPOWERS_CHG_LED_ON, | ||
- XPOWERS_CHG_LED_CTRL_CHG, | ||
* */ | ||
PMU.setChargingLedMode(XPOWERS_CHG_LED_ON); | ||
|
||
//Default turn on adc | ||
adcOn(); | ||
|
||
} | ||
|
||
|
||
|
||
|
||
void loop() | ||
{ | ||
|
||
if (pmu_flag) { | ||
pmu_flag = false; | ||
// Get PMU Interrupt Status Register | ||
uint32_t status = PMU.getIrqStatus(); | ||
if (PMU.isPekeyShortPressIrq()) { | ||
if (adc_switch) { | ||
adcOn(); Serial.println("Enable ADC\n\n\n"); | ||
} else { | ||
adcOff(); Serial.println("Disable ADC\n\n\n"); | ||
} | ||
adc_switch = !adc_switch; | ||
} | ||
// Clear PMU Interrupt Status Register | ||
PMU.clearIrqStatus(); | ||
} | ||
|
||
Serial.print("PMU Temperature:"); Serial.print(PMU.getTemperature()); Serial.println("*C"); | ||
Serial.print("isCharging:"); Serial.println(PMU.isCharging() ? "YES" : "NO"); | ||
Serial.print("isDischarge:"); Serial.println(PMU.isDischarge() ? "YES" : "NO"); | ||
Serial.print("isStandby:"); Serial.println(PMU.isStandby() ? "YES" : "NO"); | ||
Serial.print("isVbusIn:"); Serial.println(PMU.isVbusIn() ? "YES" : "NO"); | ||
Serial.print("isVbusGood:"); Serial.println(PMU.isVbusGood() ? "YES" : "NO"); | ||
Serial.print("getChargerStatus:"); | ||
uint8_t charge_status = PMU.getChargerStatus(); | ||
if (charge_status == XPOWERS_AXP2101_CHG_TRI_STATE) { | ||
Serial.println("tri_charge"); | ||
} else if (charge_status == XPOWERS_AXP2101_CHG_PRE_STATE) { | ||
Serial.println("pre_charge"); | ||
} else if (charge_status == XPOWERS_AXP2101_CHG_CC_STATE) { | ||
Serial.println("constant charge"); | ||
} else if (charge_status == XPOWERS_AXP2101_CHG_CV_STATE) { | ||
Serial.println("constant voltage"); | ||
} else if (charge_status == XPOWERS_AXP2101_CHG_DONE_STATE) { | ||
Serial.println("charge done"); | ||
} else if (charge_status == XPOWERS_AXP2101_CHG_STOP_STATE) { | ||
Serial.println("not chargin"); | ||
} | ||
|
||
// After the ADC detection is turned off, the register will return to the last reading. The PMU will not refresh the data register | ||
Serial.print("getBattVoltage:"); Serial.print(PMU.getBattVoltage()); Serial.println("mV"); | ||
Serial.print("getVbusVoltage:"); Serial.print(PMU.getVbusVoltage()); Serial.println("mV"); | ||
Serial.print("getSystemVoltage:"); Serial.print(PMU.getSystemVoltage()); Serial.println("mV"); | ||
|
||
// The battery percentage may be inaccurate at first use, the PMU will automatically | ||
// learn the battery curve and will automatically calibrate the battery percentage | ||
// after a charge and discharge cycle | ||
if (PMU.isBatteryConnect()) { | ||
Serial.print("getBatteryPercent:"); Serial.print(PMU.getBatteryPercent()); Serial.println("%"); | ||
} | ||
|
||
// Serial.println(); | ||
delay(1000); | ||
} | ||
|
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters