Added BQ25896 examples
Browse files Browse the repository at this point in the history
  • Loading branch information
lewisxhe committed Jun 4, 2024
1 parent 8470899 commit 0ff4465
Show file tree
Hide file tree
Showing 3 changed files with 255 additions and 1 deletion.
176 changes: 176 additions & 0 deletions examples/BQ25896_Example/BQ25896_Example.ino
Original file line number Diff line number Diff line change
@@ -0,0 +1,176 @@
/**
* @file BQ25896_Example.ino
* @author Lewis He (lewishe@outlook.com)
* @license MIT
* @copyright Copyright (c) 2024 Shenzhen Xin Yuan Electronic Technology Co., Ltd
* @date 2024-06-04
*
*/
#include <XPowersLib.h>

XPowersPPM PPM;


#ifndef CONFIG_PMU_SDA
#define CONFIG_PMU_SDA 0
#endif

#ifndef CONFIG_PMU_SCL
#define CONFIG_PMU_SCL 1
#endif

#ifndef CONFIG_PMU_IRQ
#define CONFIG_PMU_IRQ 28
#endif

const uint8_t i2c_sda = CONFIG_PMU_SDA;
const uint8_t i2c_scl = CONFIG_PMU_SCL;
const uint8_t pmu_irq_pin = CONFIG_PMU_IRQ;
uint32_t cycleInterval;
bool pmu_irq = false;

void setup()
{
Serial.begin(115200);
while (!Serial);


bool result = PPM.init(Wire, i2c_sda, i2c_scl, BQ25896_SLAVE_ADDRESS);

if (result == false) {
while (1) {
Serial.println("PPM is not online...");
delay(50);
}
}

// Set the minimum operating voltage. Below this voltage, the PPM will protect
PPM.setSysPowerDownVoltage(3300);

// Set input current limit, default is 500mA
PPM.setInputCurrentLimit(3250);

Serial.printf("getInputCurrentLimit: %d mA\n",PPM.getInputCurrentLimit());

// Disable current limit pin
PPM.disableCurrentLimitPin();

// Set the charging target voltage, Range:3840 ~ 4608mV ,step:16 mV
PPM.setChargeTargetVoltage(4208);

// Set the precharge current , Range: 64mA ~ 1024mA ,step:64mA
PPM.setPrechargeCurr(64);

// The premise is that Limit Pin is disabled, or it will only follow the maximum charging current set by Limi tPin.
// Set the charging current , Range:0~5056mA ,step:64mA
PPM.setChargerConstantCurr(832);

// Get the set charging current
PPM.getChargerConstantCurr();
Serial.printf("getChargerConstantCurr: %d mA\n",PPM.getChargerConstantCurr());


// To obtain voltage data, the ADC must be enabled first
PPM.enableADCMeasure();

// Turn on charging function
// If there is no battery connected, do not turn on the charging function
PPM.enableCharge();

// Turn off charging function
// If USB is used as the only power input, it is best to turn off the charging function,
// otherwise the VSYS power supply will have a sawtooth wave, affecting the discharge output capability.
// PPM.disableCharge();


// The OTG function needs to enable OTG, and set the OTG control pin to HIGH
// After OTG is enabled, if an external power supply is plugged in, OTG will be turned off

// PPM.enableOTG();
// PPM.disableOTG();
// pinMode(OTG_ENABLE_PIN, OUTPUT);
// digitalWrite(OTG_ENABLE_PIN, HIGH);


attachInterrupt(pmu_irq_pin, []() {
pmu_irq = true;
}, FALLING);

delay(2000);
}


void loop()
{

if (pmu_irq) {
pmu_irq = false;
Serial.print("-> [");
Serial.print(millis() / 1000);
Serial.print("] ");

// Get PPM interrupt status
PPM.getIrqStatus();


if (PPM.isWatchdogFault()) {
Serial.println("Watchdog Fault");
}
if (PPM.isBoostFault()) {
Serial.println("Boost Fault");
}
if (PPM.isChargeFault()) {
Serial.println("Charge Fault");
}
if (PPM.isBatteryFault()) {
Serial.println("Batter Fault");
}
if (PPM.isNTCFault()) {
Serial.print("NTC Fault:");
Serial.print(PPM.getNTCStatusString());

Serial.print(" Percentage:");
Serial.print(PPM.getNTCPercentage()); Serial.println("%");
}
// The battery may be disconnected or damaged.
if (PPM.isVsysLowVoltageWarning()) {
Serial.println("In VSYSMIN regulation (BAT<VSYSMIN)");
}

}

// When VBUS is input, the battery voltage detection will not take effect
if (millis() > cycleInterval) {

Serial.println("Sats VBUS VBAT SYS VbusStatus String ChargeStatus String TargetVoltage ChargeCurrent Precharge NTCStatus String");
Serial.println(" (mV) (mV) (mV) (HEX) (HEX) (mV) (mA) (mA) (HEX) ");
Serial.println("--------------------------------------------------------------------------------------------------------------------------------");
Serial.print(PPM.isVbusIn() ? "Connected" : "Disconnect"); Serial.print("\t");
Serial.print(PPM.getVbusVoltage()); Serial.print("\t");
Serial.print(PPM.getBattVoltage()); Serial.print("\t");
Serial.print(PPM.getSystemVoltage()); Serial.print("\t");
Serial.print("0x");
Serial.print(PPM.getBusStatus(), HEX); Serial.print("\t");
Serial.print(PPM.getBusStatusString()); Serial.print("\t");
Serial.print("0x");
Serial.print(PPM.chargeStatus(), HEX); Serial.print("\t");
Serial.print(PPM.getChargeStatusString()); Serial.print("\t");

Serial.print(PPM.getChargeTargetVoltage()); Serial.print("\t");
Serial.print(PPM.getChargeCurrent()); Serial.print("\t");
Serial.print(PPM.getPrechargeCurr()); Serial.print("\t");
Serial.print(PPM.getNTCStatus()); Serial.print("\t");
Serial.print(PPM.getNTCStatusString()); Serial.print("\t");


Serial.println();
Serial.println();
cycleInterval = millis() + 1000;
}

}





70 changes: 70 additions & 0 deletions examples/BQ25896_Shutdown_Example/BQ25896_Shutdown_Example.ino
Original file line number Diff line number Diff line change
@@ -0,0 +1,70 @@
/**
* @file BQ25896_Shutdown_Example.ino
* @author Lewis He (lewishe@outlook.com)
* @license MIT
* @copyright Copyright (c) 2024 Shenzhen Xin Yuan Electronic Technology Co., Ltd
* @date 2024-06-04
*
*/
#include <XPowersLib.h>

XPowersPPM PPM;


#ifndef CONFIG_PMU_SDA
#define CONFIG_PMU_SDA 0
#endif

#ifndef CONFIG_PMU_SCL
#define CONFIG_PMU_SCL 1
#endif

#ifndef CONFIG_PMU_IRQ
#define CONFIG_PMU_IRQ 28
#endif

const uint8_t i2c_sda = CONFIG_PMU_SDA;
const uint8_t i2c_scl = CONFIG_PMU_SCL;
const uint8_t pmu_irq_pin = CONFIG_PMU_IRQ;
uint32_t cycleInterval;
uint32_t countdown = 10;


void setup()
{
Serial.begin(115200);
while (!Serial);

bool result = PPM.init(Wire, i2c_sda, i2c_scl, BQ25896_SLAVE_ADDRESS);
if (result == false) {
while (1) {
Serial.println("PPM is not online...");
delay(1000);
}
}

}


void loop()
{
if (millis() > cycleInterval) {
Serial.printf("%d\n", countdown);
if (!(countdown--)) {
Serial.println("Shutdown .....");
// The shutdown function can only be used when the battery is connected alone,
// and cannot be shut down when connected to USB.
// It can only be powered on in the following two ways:
// 1. Press the PPM/QON button
// 2. Connect to USB
PPM.shutdown();
countdown = 10000;
}
cycleInterval = millis() + 1000;
}
}





10 changes: 9 additions & 1 deletion platformio.ini
Original file line number Diff line number Diff line change
Expand Up @@ -12,7 +12,7 @@
; src_dir = examples/AXP192_Example
; src_dir = examples/AXP202_Example
; src_dir = examples/AXP2101_Charge_Example
src_dir = examples/AXP2101_Charge_Current_Setting
; src_dir = examples/AXP2101_Charge_Current_Setting
; src_dir = examples/AXP2101_Example
; src_dir = examples/AXP2101_InterruptExample
; src_dir = examples/AXP2101_Voltage_Example
Expand All @@ -23,6 +23,9 @@ src_dir = examples/AXP2101_Charge_Current_Setting
; src_dir = examples/SY6970_Watchdog_Example
; src_dir = examples/SY6970_Shutdown_Example

; src_dir = examples/BQ25896_Example
src_dir = examples/BQ25896_Shutdown_Example

default_envs=esp32s3
; default_envs=esp32dev
; default_envs=nucleo_f411re
Expand All @@ -38,6 +41,11 @@ build_flags =
; -DCONFIG_PMU_SDA=1
; -DCONFIG_PMU_SCL=2

; T-EPD47 S3
-DCONFIG_PMU_SDA=6
-DCONFIG_PMU_SCL=5
-DCONFIG_PMU_IRQ=15

; -DCONFIG_PMU_SDA=3
; -DCONFIG_PMU_SCL=2
; -DCONFIG_PMU_IRQ=15
Expand Down