Fix the Renpho Air Purifier AQI sensor, since AQI is deprecated. #1832
Conversation
Where are you seeing that aqi device class is deprecated? It is not mentioned in the documentation, and there is no blog post about it. |
HA Also complains about it, and this fixes it. |
|
From the sensor classes, AQI according to the docs has no units defined..
but it wants an int/float, not a string. |
I see they have added a list of non-numeric device classes, and aqi is not among them. I guess it does make sense, since the I in AQI stands for index, so it should really be numeric, even though many devices have something labelled AQI which is a good/fair/poor categorisation like this. |
This fixes the deprecated AQI sensor setting in the Renpho Air Purifier, changing it from AQI to enum with a string mapping.
I've tested this against my purifiers, and it works.