Skip to content

Commit

Permalink
[openwebnet] add support for WHO=2 Automation (openhab#8437)
Browse files Browse the repository at this point in the history
* update openwebnet4j to 0.3.0.
* Closes openhab#8436 

Signed-off-by: Massimo Valla <mvcode00@gmail.com>
  • Loading branch information
mvalla authored and markus7017 committed Sep 18, 2020
1 parent e245707 commit de760d7
Show file tree
Hide file tree
Showing 12 changed files with 603 additions and 9 deletions.
23 changes: 21 additions & 2 deletions bundles/org.openhab.binding.openwebnet/README.md
Original file line number Diff line number Diff line change
Expand Up @@ -39,13 +39,15 @@ The following Things and OpenWebNet `WHOs` are supported:
| -------------------- | :----------: | :---------------------------------: | ----------------------------------------------------------- | ---------------- |
| Gateway Management | `13` | `bus_gateway` | Any IP gateway supporting OpenWebNet protocol should work (e.g. F454 / MyHOMEServer1 / MH202 / F455 / MH200N, ...) | Successfully tested: F454, MyHOMEServer1, MyHOME_Screen10, F455, F452, F453AV, MH201, MH202, MH200N. Some connection stability issues/gateway resets reported with MH202 |
| Lighting | `1` | `bus_on_off_switch`, `bus_dimmer` | BUS switches and dimmers. | Successfully tested: F411/2, F411/4, F411U2, F422, F429. Some discovery issues reported with F429 (DALI Dimmers) |
| Automation | `2` | `bus_automation` | BUS roller shutters, with position feedback and auto-calibration | Successfully tested: LN4672M2 |

### For ZigBee (Radio)

| Category | WHO | Thing Type IDs | Description | Status |
| ---------- | :---: | :-------------------------------: | :-------------------------------------------------------------------: | ------------------------------------ |
| Gateway | `13` | `zb_gateway` | Wireless ZigBee USB Gateway (models: BTI-3578 / LG 088328) | Tested: BTI-3578 and LG 088328 |
| Lighting | `1` | `zb_dimmer`, `zb_on_off_switch`, `zb_on_off_switch2u` | ZigBee dimmers, switches and 2-unit switches | Tested: BTI-4591, BTI-3584, BTI-4585 |
| Automation | `2` | `zb_automation` | ZigBee roller shutters | |

## Discovery

Expand Down Expand Up @@ -128,8 +130,22 @@ Devices support some of the following channels:

| Channel Type ID (channel ID) | Item Type | Description | Read/Write |
|--------------------------|---------------|-------------------------------------------------------------------------|:----------:|
| `switch` | Switch | To switch the device `ON` and `OFF` | R/W |
| `brightness` | Dimmer | To adjust the brightness value (Percent, `ON`, `OFF`) | R/W |
| `switch` | Switch | To switch the device `ON` and `OFF` | R/W |
| `brightness` | Dimmer | To adjust the brightness value (Percent, `ON`, `OFF`) | R/W |
| `shutter` | Rollershutter | To activate roller shutters (`UP`, `DOWN`, `STOP`, Percent - [see Shutter position](#shutter-position)) | R/W |

### Notes on channels

#### `shutter` position

For Percent commands and position feedback to work correctly, the `shutterRun` Thing config parameter must be configured equal to the time (in ms) to go from full UP to full DOWN.
It's possible to enter a value manually or set `shutterRun=AUTO` (default) to calibrate `shutterRun` automatically: in this case a *UP >> DOWN >> Position%* cycle will be performed automatically the first time a Percent command is sent to the shutter.

- if `shutterRun` is not set, or is set to AUTO but calibration has not been performed yet, then position estimation will remain `UNDEFINED`
- if `shutterRun` is wrongly set higher than the actual runtime, then position estimation will remain `UNDEFINED`: try to reduce shutterRun until you find the right value
- before adding/configuring roller shutter Things it is suggested to have all roller shutters `UP`, otherwise the Percent command won’t work until the roller shutter is fully rolled up
- if the gateways gets disconnected the binding cannot estimate anymore the shutter positions: just roll the shutter all `UP` or `DOWN` and its position will be estimated again
- the shutter position is estimated based on UP/DOWN timing: an error of ±2% is normal

## Full Example

Expand All @@ -140,6 +156,7 @@ Bridge openwebnet:bus_gateway:mybridge "MyHOMEServer1" [ host="192.168.1.35", pa
bus_on_off_switch LR_switch "Living Room Light" [ where="51" ]
bus_dimmer LR_dimmer "Living Room Dimmer" [ where="25#4#01" ]
bus_dimmer LR_dalidimmer "Living Room Dali-Dimmer" [ where="0311#4#01" ]
bus_automation LR_shutter "Living Room Shutter" [ where="93", shutterRun="10050"]
}
```

Expand All @@ -161,6 +178,7 @@ Switch iLR_switch "Light" <light>
Dimmer iLR_dimmer "Dimmer [%.0f %%]" <DimmableLight> (gLivingRoom) [ "Lighting" ] { channel="openwebnet:bus_dimmer:mybridge:LR_dimmer:brightness" }
Dimmer iLR_dalidimmer "Dali-Dimmer [%.0f %%]" <DimmableLight> (gLivingRoom) [ "Lighting" ] { channel="openwebnet:bus_dimmer:mybridge:LR_dalidimmer:brightness" }
/* For Dimmers, use category DimmableLight to have Off/On switch in addition to the Percent slider in PaperUI */
Rollershutter iLR_shutter "Shutter [%.0f %%]" <rollershutter> (gShutters, gLivingRoom) [ "Blinds" ] { channel="openwebnet:bus_automation:mybridge:LR_shutter:shutter" }
```

### openwebnet.sitemap
Expand All @@ -173,6 +191,7 @@ sitemap openwebnet label="OpenWebNet Binding Example Sitemap"
Default item=iLR_switch icon="light"
Default item=iLR_dimmer icon="light"
Default item=iLR_dalidimmer icon="light"
Default item=iLR_shutter
}
}
```
Expand Down
2 changes: 1 addition & 1 deletion bundles/org.openhab.binding.openwebnet/pom.xml
Original file line number Diff line number Diff line change
Expand Up @@ -23,7 +23,7 @@
<dependency>
<groupId>com.github.openwebnet4j</groupId>
<artifactId>openwebnet4j</artifactId>
<version>0.2.0</version>
<version>0.3.0</version>
<scope>compile</scope>
</dependency>

Expand Down
Original file line number Diff line number Diff line change
Expand Up @@ -50,6 +50,8 @@ public class OpenWebNetBindingConstants {
public static final String THING_LABEL_BUS_ON_OFF_SWITCH = "Switch";
public static final ThingTypeUID THING_TYPE_BUS_DIMMER = new ThingTypeUID(BINDING_ID, "bus_dimmer");
public static final String THING_LABEL_BUS_DIMMER = "Dimmer";
public static final ThingTypeUID THING_TYPE_BUS_AUTOMATION = new ThingTypeUID(BINDING_ID, "bus_automation");
public static final String THING_LABEL_BUS_AUTOMATION = "Automation";

// ZIGBEE
public static final ThingTypeUID THING_TYPE_ZB_ON_OFF_SWITCH = new ThingTypeUID(BINDING_ID, "zb_on_off_switch");
Expand All @@ -59,21 +61,25 @@ public class OpenWebNetBindingConstants {
public static final String THING_LABEL_ZB_ON_OFF_SWITCH_2UNITS = "ZigBee 2-units Switch";
public static final ThingTypeUID THING_TYPE_ZB_DIMMER = new ThingTypeUID(BINDING_ID, "zb_dimmer");
public static final String THING_LABEL_ZB_DIMMER = "ZigBee Dimmer";
public static final ThingTypeUID THING_TYPE_ZB_AUTOMATION = new ThingTypeUID(BINDING_ID, "zb_automation");
public static final String THING_LABEL_ZB_AUTOMATION = "ZigBee Automation";

// #SUPPORTED THINGS SETS
// ## Generic
public static final Set<ThingTypeUID> GENERIC_SUPPORTED_THING_TYPES = new HashSet<>(
Arrays.asList(THING_TYPE_GENERIC_DEVICE));

// ## Lighting
public static final Set<ThingTypeUID> LIGHTING_SUPPORTED_THING_TYPES = new HashSet<>(
Arrays.asList(THING_TYPE_ZB_ON_OFF_SWITCH, THING_TYPE_ZB_ON_OFF_SWITCH_2UNITS, THING_TYPE_ZB_DIMMER,
THING_TYPE_BUS_ON_OFF_SWITCH, THING_TYPE_BUS_DIMMER));
// ## Automation
public static final Set<ThingTypeUID> AUTOMATION_SUPPORTED_THING_TYPES = new HashSet<>(
Arrays.asList(THING_TYPE_ZB_AUTOMATION, THING_TYPE_BUS_AUTOMATION));

// ## Groups
public static final Set<ThingTypeUID> DEVICE_SUPPORTED_THING_TYPES = Stream
.of(LIGHTING_SUPPORTED_THING_TYPES, GENERIC_SUPPORTED_THING_TYPES).flatMap(Collection::stream)
.collect(Collectors.toCollection(HashSet::new));
.of(LIGHTING_SUPPORTED_THING_TYPES, AUTOMATION_SUPPORTED_THING_TYPES, GENERIC_SUPPORTED_THING_TYPES)
.flatMap(Collection::stream).collect(Collectors.toCollection(HashSet::new));

public static final Set<ThingTypeUID> BRIDGE_SUPPORTED_THING_TYPES = new HashSet<>(
Arrays.asList(THING_TYPE_ZB_GATEWAY, THING_TYPE_BUS_GATEWAY));
Expand All @@ -88,9 +94,13 @@ public class OpenWebNetBindingConstants {
public static final String CHANNEL_SWITCH_01 = "switch_01";
public static final String CHANNEL_SWITCH_02 = "switch_02";
public static final String CHANNEL_BRIGHTNESS = "brightness";
// automation
public static final String CHANNEL_SHUTTER = "shutter";

// devices config properties
public static final String CONFIG_PROPERTY_WHERE = "where";
public static final String CONFIG_PROPERTY_SHUTTER_RUN = "shutterRun";

// BUS gw config properties
public static final String CONFIG_PROPERTY_HOST = "host";
// properties
Expand Down
Loading

0 comments on commit de760d7