An alternate fix to class(*) issues with FMS 2022-01
Browse files Browse the repository at this point in the history
- This update is an alternate to PR#66 to fix the issues with passing
  read arguments to subroutines receiving class(*)

- This tries to show that there are no inherent issues with passing a
  real and receiving it as class(*).
  Rather the root cause of the issues is some of these arguments are
  optional and are being passed to FMS even thought they are not
  present!  Then they are trapped in FMS diag_manager inside a SELECT
  TYPE statement and the compiler is not smart enough to know that they
  are absent and bombs. 
  • Loading branch information
nikizadehgfdl authored and marshallward committed Mar 29, 2022
1 parent 8ecf333 commit d380f1d
Show file tree
Hide file tree
Showing 2 changed files with 74 additions and 12 deletions.
43 changes: 37 additions & 6 deletions config_src/infra/FMS1/MOM_diag_manager_infra.F90
Original file line number Diff line number Diff line change
Expand Up @@ -236,9 +236,15 @@ integer function register_static_field_infra(module_name, field_name, axes, long
integer, optional, intent(in) :: area !< Diagnostic ID of the field containing the area attribute
integer, optional, intent(in) :: volume !< Diagnostic ID of the field containing the volume attribute

register_static_field_infra = register_static_field_fms(module_name, field_name, axes, long_name, units,&
& missing_value, range, mask_variant, standard_name, dynamic=.false.,do_not_log=do_not_log, &
if(present(missing_value) .or. present(range)) then
register_static_field_infra = register_static_field_fms(module_name, field_name, axes, long_name, units,&
& missing_value, range, mask_variant=mask_variant, standard_name=standard_name, dynamic=.false.,&
do_not_log=do_not_log, interp_method=interp_method,tile_count=tile_count, area=area, volume=volume)
else
register_static_field_infra = register_static_field_fms(module_name, field_name, axes, long_name, units,&
& mask_variant=mask_variant, standard_name=standard_name, dynamic=.false.,do_not_log=do_not_log, &
interp_method=interp_method,tile_count=tile_count, area=area, volume=volume)
endif
end function register_static_field_infra

!> Returns true if the argument data are successfully passed to a diagnostic manager
Expand Down Expand Up @@ -267,7 +273,20 @@ logical function send_data_infra_1d(diag_field_id, field, is_in, ie_in, time, ma
character(len=*), optional, intent(out) :: err_msg !< A log indicating the status of the post upon
!! returning to the calling routine

send_data_infra_1d = send_data_fms(diag_field_id, field, time, is_in, mask, rmask, ie_in, weight, err_msg)
if(present(rmask) .or. present(weight)) then
if(present(rmask) .and. present(weight)) then
send_data_infra_1d = send_data_fms(diag_field_id, field, time=time, is_in=is_in, mask=mask, rmask=rmask, ie_in=ie_in,&
weight=weight, err_msg=err_msg)
elseif(present(rmask)) then
send_data_infra_1d = send_data_fms(diag_field_id, field, time=time, is_in=is_in, mask=mask, rmask=rmask, ie_in=ie_in,&
err_msg=err_msg)
elseif(present(weight)) then
send_data_infra_1d = send_data_fms(diag_field_id, field, time=time, is_in=is_in, ie_in=ie_in, weight=weight,&
err_msg=err_msg)
endif
else
send_data_infra_1d = send_data_fms(diag_field_id, field, time=time, is_in=is_in, ie_in=ie_in, err_msg=err_msg)
endif

end function send_data_infra_1d

Expand All @@ -289,9 +308,21 @@ logical function send_data_infra_2d(diag_field_id, field, is_in, ie_in, js_in, j
character(len=*), optional, intent(out) :: err_msg !< A log indicating the status of the post upon
!! returning to the calling routine

send_data_infra_2d = send_data_fms(diag_field_id, field, time, is_in, js_in, mask, &
rmask, ie_in, je_in, weight, err_msg)

if(present(rmask) .or. present(weight)) then
if(present(rmask) .and. present(weight)) then
send_data_infra_2d = send_data_fms(diag_field_id, field, time=time, is_in=is_in, js_in=js_in, mask=mask, &
rmask=rmask, ie_in=ie_in, je_in=je_in, weight=weight, err_msg=err_msg)
elseif(present(rmask)) then
send_data_infra_2d = send_data_fms(diag_field_id, field, time=time, is_in=is_in, js_in=js_in, mask=mask, &
rmask=rmask, ie_in=ie_in, je_in=je_in, err_msg=err_msg)
elseif(present(weight)) then
send_data_infra_2d = send_data_fms(diag_field_id, field, time=time, is_in=is_in, js_in=js_in, mask=mask, &
ie_in=ie_in, je_in=je_in, weight=weight, err_msg=err_msg)
endif
else
send_data_infra_2d = send_data_fms(diag_field_id, field, time=time, is_in=is_in, js_in=js_in, mask=mask, &
ie_in=ie_in, je_in=je_in, err_msg=err_msg)
endif
end function send_data_infra_2d

!> Returns true if the argument data are successfully passed to a diagnostic manager
Expand Down
43 changes: 37 additions & 6 deletions config_src/infra/FMS2/MOM_diag_manager_infra.F90
Original file line number Diff line number Diff line change
Expand Up @@ -236,9 +236,15 @@ integer function register_static_field_infra(module_name, field_name, axes, long
integer, optional, intent(in) :: area !< Diagnostic ID of the field containing the area attribute
integer, optional, intent(in) :: volume !< Diagnostic ID of the field containing the volume attribute

register_static_field_infra = register_static_field_fms(module_name, field_name, axes, long_name, units,&
& missing_value, range, mask_variant, standard_name, dynamic=.false.,do_not_log=do_not_log, &
if(present(missing_value) .or. present(range)) then
register_static_field_infra = register_static_field_fms(module_name, field_name, axes, long_name, units,&
& missing_value, range, mask_variant=mask_variant, standard_name=standard_name, dynamic=.false.,&
do_not_log=do_not_log, interp_method=interp_method,tile_count=tile_count, area=area, volume=volume)
else
register_static_field_infra = register_static_field_fms(module_name, field_name, axes, long_name, units,&
& mask_variant=mask_variant, standard_name=standard_name, dynamic=.false.,do_not_log=do_not_log, &
interp_method=interp_method,tile_count=tile_count, area=area, volume=volume)
endif
end function register_static_field_infra

!> Returns true if the argument data are successfully passed to a diagnostic manager
Expand Down Expand Up @@ -267,7 +273,20 @@ logical function send_data_infra_1d(diag_field_id, field, is_in, ie_in, time, ma
character(len=*), optional, intent(out) :: err_msg !< A log indicating the status of the post upon
!! returning to the calling routine

send_data_infra_1d = send_data_fms(diag_field_id, field, time, is_in, mask, rmask, ie_in, weight, err_msg)
if(present(rmask) .or. present(weight)) then
if(present(rmask) .and. present(weight)) then
send_data_infra_1d = send_data_fms(diag_field_id, field, time=time, is_in=is_in, mask=mask, rmask=rmask, ie_in=ie_in,&
weight=weight, err_msg=err_msg)
elseif(present(rmask)) then
send_data_infra_1d = send_data_fms(diag_field_id, field, time=time, is_in=is_in, mask=mask, rmask=rmask, ie_in=ie_in,&
err_msg=err_msg)
elseif(present(weight)) then
send_data_infra_1d = send_data_fms(diag_field_id, field, time=time, is_in=is_in, ie_in=ie_in, weight=weight,&
err_msg=err_msg)
endif
else
send_data_infra_1d = send_data_fms(diag_field_id, field, time=time, is_in=is_in, ie_in=ie_in, err_msg=err_msg)
endif

end function send_data_infra_1d

Expand All @@ -289,9 +308,21 @@ logical function send_data_infra_2d(diag_field_id, field, is_in, ie_in, js_in, j
character(len=*), optional, intent(out) :: err_msg !< A log indicating the status of the post upon
!! returning to the calling routine

send_data_infra_2d = send_data_fms(diag_field_id, field, time, is_in, js_in, mask, &
rmask, ie_in, je_in, weight, err_msg)

if(present(rmask) .or. present(weight)) then
if(present(rmask) .and. present(weight)) then
send_data_infra_2d = send_data_fms(diag_field_id, field, time=time, is_in=is_in, js_in=js_in, mask=mask, &
rmask=rmask, ie_in=ie_in, je_in=je_in, weight=weight, err_msg=err_msg)
elseif(present(rmask)) then
send_data_infra_2d = send_data_fms(diag_field_id, field, time=time, is_in=is_in, js_in=js_in, mask=mask, &
rmask=rmask, ie_in=ie_in, je_in=je_in, err_msg=err_msg)
elseif(present(weight)) then
send_data_infra_2d = send_data_fms(diag_field_id, field, time=time, is_in=is_in, js_in=js_in, mask=mask, &
ie_in=ie_in, je_in=je_in, weight=weight, err_msg=err_msg)
endif
else
send_data_infra_2d = send_data_fms(diag_field_id, field, time=time, is_in=is_in, js_in=js_in, mask=mask, &
ie_in=ie_in, je_in=je_in, err_msg=err_msg)
endif
end function send_data_infra_2d

!> Returns true if the argument data are successfully passed to a diagnostic manager
Expand Down

0 comments on commit d380f1d

Please sign in to comment.