MQTT bridge for NBE V7/10/13 pellet boiler controllers.

License

Notifications You must be signed in to change notification settings

mlipscombe/boiler-mate

Repository files navigation

boiler-mate

boiler-mate acts as a simple MQTT bridge from wood pellet boilers compatible with NBE V7/10/13 controllers, used by various manufacturers.

Supported Boilers

Any boiler with a controller that is managed through [https://stokercloud.dk] should be compatible as long as it has the correct firmware firmware installed.

Possibly compatible manufacturers/models include:

  • NBE Blackstar
  • NBE RTB
  • Kedel
  • Opop

Controller Firmware

If your boiler has a V7 or V10 controller, you need the firmware version that removes the user interface on the touch screen, but enables access on the local network.

To upgrade, go to [https://www.nbe.dk/program-download/] and select "Activate Controller for App Operation" and follow the steps.

How to Run

Synopsis:

    Usage of boiler-mate:
        --debug
            debug mode
        --bind string
            address to bind for healthz and prometheus metrics endpoint, or "false"
            to disable (default "0.0.0.0:2112")
        --controller string
            controller URI, in the format tcp://<serial>:<password>@<host>:<port>
        --mqtt string
            MQTT URI, in the format mqtt[s]://[<user>:<password>]@<host>:<port>[/<prefix>][?tls_cert=<cert_file>][&tls_key=<key_file>][&tls_ca=<ca_file>]
            (default "mqtt://localhost:1883")

Example:

    # Run with basic options
    boiler-mate --host udp://3629:0587451614@192.168.1.100:8483 --mqtt mqtt://10.10.11.20:1883

    # Run with TLS
    boiler-mate --host udp://3629:0587451614@192.168.1.100:8483 --mqtt mqtts://10.10.11.20:8883

    # Run with mutual TLS
    boiler-mate --host udp://3629:0587451614@192.168.1.100:8483 --mqtt mqtts://10.10.11.20:8883?tls_cert=client.crt&tls_key=client.key

Each command-line option can also be specified by an equivilent environment variable, prefixed with BOILER_MATE_. For example, to set the MQTT URI to mqtt://mqtt:1833, you can set the environment variable BOILER_MATE_MQTT=mqtt://mqtt:1833.

The boiler's password is required to write settings, but not to read them. You can find controller's serial number and password in the top right corner of the display on the unit.

If an MQTT prefix is not specified, messages will be published to the nbe/<serial> topic.

Thanks & Acknowledgement

Special thanks to Anders Nylund for documenting the NBE protocol.