Virtual Chassis LAG configuration #1843

Closed
ghost opened this issue Jan 29, 2018 · 4 comments
Closed

Virtual Chassis LAG configuration #1843

ghost opened this issue Jan 29, 2018 · 4 comments
Labels
type: bug A confirmed report of unexpected behavior in the application

Comments

@ghost
Copy link

ghost commented Jan 29, 2018

Issue type
[X] Feature request
[] Bug report
[] Documentation

Environment
Python version: 3.6
NetBox version: 2.3-beta1

Description
The new virtual chassis function doesn't include the LAG configuration inside the virtual chassis. When you are adding a LAG interface on one of the VC member its not possible to choose the LAG on one of the other devices. Its possible to add this feature in a new version?

@lampwins
Copy link
Contributor

I think this should also include virtual interfaces. The virtual chassis implementation is a great step forward, but I do not think in the current form, it solves the control plane model. In a virtual chassis, a physical interface may reside on a member, but it belongs to the virtual chassis, not that member, from a control plane perspective. LAG and virtual interfaces present an equally challenging case in that they only belong to the virtual chassis. So I still think the interfaces actually need to be stripped from the individual members and assigned only to the virtual chassis. When viewing an individual member, it makes sense to be able to see the interfaces that physically reside on that member. But doing so would allow LAG and virtual interfaces to be assigned to just the virtual chassis and for LAG member interfaces to span all members.

@jeremystretch jeremystretch added type: bug A confirmed report of unexpected behavior in the application status: accepted This issue has been accepted for implementation beta labels Jan 30, 2018
@jeremystretch
Copy link
Member

I did some work on this in 1cd629e; please try it out and let me know what you think.

For LAGs and virtual interfaces in general, the answer is going to be "only define them on the VC master." It's not ideal, but it's the most practical approach we have for now.

@jeremystretch jeremystretch added status: under review Further discussion is needed to determine this issue's scope and/or implementation and removed status: accepted This issue has been accepted for implementation labels Jan 30, 2018
@jeremystretch
Copy link
Member

This appears to be resolved. (Even if it isn't, please try any further testing on the develop-2.3 branch as the VirtualChassis data model has been overhauled.)

@dgarros
Copy link
Contributor

dgarros commented Feb 2, 2018

@jeremystretch do you have a summary of the changes you are planning to make to the VC data model ?

I tried the current implementation in 2.3beta1 and I'm still trying to figure out the best way to consume a VC and easily collect all information needed to generate the configuration.

Thks

funzoneq added a commit to openfibernet/netbox that referenced this issue Mar 8, 2018
* Closes netbox-community#1553: Introduced support for bulk object creation via the API

* Removed prefix `parent` filter (see netbox-community#1684)

* Restored search method on prefix filter

* Extended prefix 'available-ips' endpoint to accept multiple objects (related to netbox-community#1553)

* Standardize on JSON data format for all POST/PUT test client requests

* netbox-community#1694: Initial work on "next available" prefix provisioning

* Closes netbox-community#1706: Added deprecation warning for Python 2

* Merge branch '150-interface-vlans' into develop-2.3

* Fixed up validation of Interface VLAN assignments

* Fixes netbox-community#1645: Simplified interface serialzier for IP addresses and optimized API view queryset

* Cleaned up bulk IP provisioning a bit

* Add Tenancy to Rack Reservations; Fixes netbox-community#1592 (netbox-community#1672)

* fixed prefix header to represent new serial "vlan_vid"

* shows option in creation now

* fixed visibility on rack page

* cleanup

* Added view to Tenant page

* Moved migration for update from netbox-community#1666 and fixed tenant enumeration in FilterForm

* Fixed conflict #1

* Fixed filters from merge and made migration merge

* added tenant to api

* Fixed migrations problem

* Added Tenant to bulkedit option

* Resolved migration collision from netbox-community#1672

* A bit of cosmetic cleanup from netbox-community#1672

* Added nested representations of user and tenant to the rack reservation serializer

* Fixed version number

* Initial work on virtual chassis support

* Moved VC master designation to membership model

* Added initial UI views for virtual chassis assignment

* Fixes netbox-community#1727: Added missing import for M2M_FIELD_TYPES

* Added a form to edit virtual chassis

* Added views for editing/deleting VCMemberships

* Display member interfaces when viewing VC master device

* Added virtual_chassis_id API filter for interfaces

* Obsoleted ComponentEditView and ComponentDeleteView

* Added virtual chassis tests

* Allow designating primary IPs assigned to a device's peer VC members

* Return all VC member interfaces when filtering for the master device; remove virtual_chassis_id filter

* Ignore VC member interfaces where mgmt_only=True

* PEP8 fixes

* Closes netbox-community#1744: Allow associating a platform with a specific manufacturer

* Closes netbox-community#1283: Added a time zone field to the site model

* Fixes netbox-community#1136: Enforce model validation during bulk update

* Closes netbox-community#1321: Added created and last_updated fields for relevant models to their API serializers

* Cleaned up component tables and checkbox toggling

* More table cleanup

* Converted remaining legacy views to class-based views for the DCIM app

* Added bulk creation API tests

* Fix bulk creation of VCMemberships via API

* Fix bulk creation of Secrets via API

* Closes netbox-community#1781: Enable bulk renaming of device components

* Implemented a view for adding individual devices to an existing virtual chassis

* Completed virtual chassis API serializers

* Reflect virtual chassis membership in display_name

* Extend IP address device filter to match virtual chassis members

* Added VirtualChassis to the docs

* Allow interface mode to be null (for routed interfaces)

* Highlight renamed components and allow for multiple previews

* Renamed device status constants for clarity

* Closes netbox-community#1758: Added 'status' field to Site model

* Closes netbox-community#1821: Added 'description' field to Site model

* Removed support for NAPALM 1.x

* Fixes netbox-community#1847: Fix RecursionError when VC master device is unnamed

* Fixes netbox-community#1848: Allow null value for interface encapsulation mode

* netbox-community#1843: Allow assignment of VC member interfaces to VC master LAG

* Fixes netbox-community#1838: Fix KeyError when attempting to create a VirtualChassis with no devicesselected

* Collapsed VCMembership into the Device model (WIP)

* Added virtual chassis member add view

* Added virtual chassis member remove view

* Cleaned up API for virtual chassis

* Added virtual chassis tests

* Additional validation cleanup

* Allow assignment of services to IPs on any VC member

* Closes netbox-community#1864: Added a 'status' field to the circuit model

* Fixes netbox-community#1867: Allow filtering on device status with multiple values

* Upgraded jquery to v3.3.1

* Fix for bulk interface edit form 802.1Q settings (netbox-community#1882)

* fixes netbox-community#1881 - bulk interface 802.1Q settings form

* fix PEP8 newline

* PEP8 fixup

* Fixes netbox-community#1884: Provide additional context to identify devices when creating/editing avirtual chassis

* VirtualChassis form validation cleanup

* Fixed typo in template

* Exclude devices already assigned to a VC from the list of potential VC members

* Finished VirtualChassis list view

* Post-release version bump

* Initial model for Packages model

* Add package_list

* Add migrations

* Adding package add form

* Import CSV Packages feature

* Adding filters

* Working bulkedit functionality for packages

* Require a package for a customer circuit

* Add edit and delete views for packages

* Add API support

* Expose package detail via the API endpoint

* Formatting correction

* Corrected order of arguments on DeviceVCMembershipForm

* Closes netbox-community#1899: Prefer binary package of psycopg2

* Updated requirements list

* Fixes netbox-community#1907: Allow removing an IP as the primary for a device when editing the IP directly

* Release v2.3.0

* NETOPS-704 Rename Tenant Group to Service Providers and Tenants to Customers

* NETOPS-704 Some small detail names fixed

* Fixes
funzoneq added a commit to openfibernet/netbox that referenced this issue Mar 8, 2018
* Closes netbox-community#1553: Introduced support for bulk object creation via the API

* Removed prefix `parent` filter (see netbox-community#1684)

* Restored search method on prefix filter

* Extended prefix 'available-ips' endpoint to accept multiple objects (related to netbox-community#1553)

* Standardize on JSON data format for all POST/PUT test client requests

* netbox-community#1694: Initial work on "next available" prefix provisioning

* Closes netbox-community#1706: Added deprecation warning for Python 2

* Merge branch '150-interface-vlans' into develop-2.3

* Fixed up validation of Interface VLAN assignments

* Fixes netbox-community#1645: Simplified interface serialzier for IP addresses and optimized API view queryset

* Cleaned up bulk IP provisioning a bit

* Add Tenancy to Rack Reservations; Fixes netbox-community#1592 (netbox-community#1672)

* fixed prefix header to represent new serial "vlan_vid"

* shows option in creation now

* fixed visibility on rack page

* cleanup

* Added view to Tenant page

* Moved migration for update from netbox-community#1666 and fixed tenant enumeration in FilterForm

* Fixed conflict #1

* Fixed filters from merge and made migration merge

* added tenant to api

* Fixed migrations problem

* Added Tenant to bulkedit option

* Resolved migration collision from netbox-community#1672

* A bit of cosmetic cleanup from netbox-community#1672

* Added nested representations of user and tenant to the rack reservation serializer

* Fixed version number

* Initial work on virtual chassis support

* Moved VC master designation to membership model

* Added initial UI views for virtual chassis assignment

* Fixes netbox-community#1727: Added missing import for M2M_FIELD_TYPES

* Added a form to edit virtual chassis

* Added views for editing/deleting VCMemberships

* Display member interfaces when viewing VC master device

* Added virtual_chassis_id API filter for interfaces

* Obsoleted ComponentEditView and ComponentDeleteView

* Added virtual chassis tests

* Allow designating primary IPs assigned to a device's peer VC members

* Return all VC member interfaces when filtering for the master device; remove virtual_chassis_id filter

* Ignore VC member interfaces where mgmt_only=True

* PEP8 fixes

* Closes netbox-community#1744: Allow associating a platform with a specific manufacturer

* Closes netbox-community#1283: Added a time zone field to the site model

* Fixes netbox-community#1136: Enforce model validation during bulk update

* Closes netbox-community#1321: Added created and last_updated fields for relevant models to their API serializers

* Cleaned up component tables and checkbox toggling

* More table cleanup

* Converted remaining legacy views to class-based views for the DCIM app

* Added bulk creation API tests

* Fix bulk creation of VCMemberships via API

* Fix bulk creation of Secrets via API

* Closes netbox-community#1781: Enable bulk renaming of device components

* Implemented a view for adding individual devices to an existing virtual chassis

* Completed virtual chassis API serializers

* Reflect virtual chassis membership in display_name

* Extend IP address device filter to match virtual chassis members

* Added VirtualChassis to the docs

* Allow interface mode to be null (for routed interfaces)

* Highlight renamed components and allow for multiple previews

* Renamed device status constants for clarity

* Closes netbox-community#1758: Added 'status' field to Site model

* Closes netbox-community#1821: Added 'description' field to Site model

* Removed support for NAPALM 1.x

* Fixes netbox-community#1847: Fix RecursionError when VC master device is unnamed

* Fixes netbox-community#1848: Allow null value for interface encapsulation mode

* netbox-community#1843: Allow assignment of VC member interfaces to VC master LAG

* Fixes netbox-community#1838: Fix KeyError when attempting to create a VirtualChassis with no devicesselected

* Collapsed VCMembership into the Device model (WIP)

* Added virtual chassis member add view

* Added virtual chassis member remove view

* Cleaned up API for virtual chassis

* Added virtual chassis tests

* Additional validation cleanup

* Allow assignment of services to IPs on any VC member

* Closes netbox-community#1864: Added a 'status' field to the circuit model

* Fixes netbox-community#1867: Allow filtering on device status with multiple values

* Upgraded jquery to v3.3.1

* Fix for bulk interface edit form 802.1Q settings (netbox-community#1882)

* fixes netbox-community#1881 - bulk interface 802.1Q settings form

* fix PEP8 newline

* PEP8 fixup

* Fixes netbox-community#1884: Provide additional context to identify devices when creating/editing avirtual chassis

* VirtualChassis form validation cleanup

* Fixed typo in template

* Exclude devices already assigned to a VC from the list of potential VC members

* Finished VirtualChassis list view

* Post-release version bump

* Formatting correction

* Corrected order of arguments on DeviceVCMembershipForm

* Closes netbox-community#1899: Prefer binary package of psycopg2

* Updated requirements list

* Fixes netbox-community#1907: Allow removing an IP as the primary for a device when editing the IP directly

* Release v2.3.0

* Fixes netbox-community#1915: Redirect to device view after deleting a component

* Fixes netbox-community#1919: Prevent exception when attempting to create a virtual machine without selecting devices

* Closes netbox-community#1918: Add note about copying media directory to upgrade doc

* Fixes netbox-community#1924: Include VID in VLAN lists when editing an interface

* fixed netbox-community#1921 - create interfaces with 801.1q in api

* Post-release version bump (a bit late)

* fixed form bound check for site and vlan group

* Fixes netbox-community#1927: Include all VC member interaces on A side when creating a new interface connection

* Fixes netbox-community#1921: Ignore ManyToManyFields when validating a new object created via the API

* refactor to handle M2M validation in ValidatedModelSerializer

* Fixes netbox-community#1935: Correct API validation of VLANs assigned to interfaces

* Fixes netbox-community#1934: Fixed exception when rendering export template on an object type with custom fields assigned

* Fixes netbox-community#1926: Prevent reassignment of parent device when bulk editing VC member interfaces

* Closes netbox-community#1910: Added filters for cluter group and cluster type

* Fixes netbox-community#1936: Trigger validation error when attempting to create a virtual chassis without specifying member positions

* Release v2.3.1
@jeremystretch jeremystretch removed status: under review Further discussion is needed to determine this issue's scope and/or implementation labels Nov 30, 2018
@github-actions github-actions bot locked as resolved and limited conversation to collaborators Jun 2, 2021