Why I did it
Old flow checked power_good before powering-on the module.
If the module is not powered, power_good will always remain 0 and flow will stop at the beginning.
Work item tracking
How I did it
Updated the state machine of MDF to have the right order.
How to verify it
I added logs and made sure the right order is being executed.