Commit
This commit does not belong to any branch on this repository, and may belong to a fork outside of the repository.
Fix error in fluence for dosxyznrc sources 1 and 7
Change minus sign to plus sign for particles which miss the geometry in the fluence calculation. Previously, particles that missed the geometry were subtracted from the total fluence (used to normalize the dose). This bug has been there for years, indicating, hopefully, how rarely these sources are used.