83 changes: 47 additions & 36 deletions bundles/org.openhab.binding.openthermgateway/README.md
Original file line number Diff line number Diff line change
Expand Up @@ -32,41 +32,47 @@ The configuration settings for the thing are Hostname/IP address and Port, which

The OpenTherm Gateway binding supports the following channels:

| Channel Type ID | Item Type | Description | Read Only |
|--------------------------|----------------------|----------------------------------------------------------|-----------|
| roomtemp | Number:Temperature | Current sensed room temperature | yes |
| roomsetpoint | Number:Temperature | Current room temperature setpoint | yes |
| temperaturetemporary | Number:Temperature | Temporary override room temperature setpoint | no |
| temperatureconstant | Number:Temperature | Constant override room temperature setpoint | no |
| controlsetpoint | Number:Temperature | Central heating water setpoint set at boiler | yes |
| controlsetpointrequested | Number:Temperature | Central heating water setpoint requested by thermostat | yes |
| controlsetpointoverride | Number:Temperature | Central heating water setpoint configured at gateway | no |
| dhwtemp | Number:Temperature | Domestic hot water temperature | yes |
| tdhwset | Number:Temperature | Domestic hot water temperature setpoint | yes |
| overridedhwsetpoint | Number:Temperature | Domestic hot water temperature setpoint override | no |
| flowtemp | Number:Temperature | Boiler water temperature | yes |
| returntemp | Number:Temperature | Return water temperature | yes |
| outsidetemp | Number:Temperature | Outside temperature | no |
| waterpressure | Number:Pressure | Central heating water pressure | yes |
| ch_enable | Switch | Central heating enabled set at boiler | yes |
| ch_enablerequested | Switch | Central heating enabled requested by thermostat | yes |
| ch_enableoverride | Switch | Central heating enabled overridden at gateway | yes |
| ch_mode | Switch | Central heating active | yes |
| dhw_enable | Switch | Domestic hot water enabled | yes |
| dhw_mode | Switch | Domestic hot water active | yes |
| flame | Switch | Burner active | yes |
| modulevel | Number:Dimensionless | Relative modulation level | yes |
| maxrelmdulevel | Number:Dimensionless | Maximum relative modulation level | yes |
| fault | Switch | Fault indication | yes |
| servicerequest | Switch | Service required | yes |
| lockout-reset | Switch | Lockout-reset enabled | yes |
| lowwaterpress | Switch | Low water pressure fault | yes |
| gasflamefault | Switch | Gas or flame fault | yes |
| airpressfault | Switch | Air pressure fault | yes |
| waterovtemp | Switch | Water over-temperature fault | yes |
| oemfaultcode | Switch | OEM fault code | yes |
| diag | Switch | Diagnostics indication | yes |
| sendcommand | Text | Channel to send commands to the OpenTherm Gateway device | no |
| Channel Type ID | Item Type | Description | Access |
|---------------------------|----------------------|----------------------------------------------------------|--------|
| roomtemp | Number:Temperature | Current sensed room temperature | R |
| roomsetpoint | Number:Temperature | Current room temperature setpoint | R |
| temperaturetemporary | Number:Temperature | Temporary override room temperature setpoint | R/W |
| temperatureconstant | Number:Temperature | Constant override room temperature setpoint | R/W |
| controlsetpoint | Number:Temperature | Central heating water setpoint set at boiler | R |
| controlsetpointrequested | Number:Temperature | Central heating water setpoint requested by thermostat | R |
| controlsetpointoverride | Number:Temperature | Central heating water setpoint configured at gateway | R/W |
| controlsetpoint2 | Number:Temperature | Central heating 2 water setpoint set at boiler | R |
| controlsetpoint2requested | Number:Temperature | Central heating 2 water setpoint requested by thermostat | R |
| controlsetpoint2override | Number:Temperature | Central heating 2 water setpoint configured at gateway | R/W |
| dhwtemp | Number:Temperature | Domestic hot water temperature | R |
| tdhwset | Number:Temperature | Domestic hot water temperature setpoint | R |
| overridedhwsetpoint | Number:Temperature | Domestic hot water temperature setpoint override | R/W |
| flowtemp | Number:Temperature | Boiler water temperature | R |
| returntemp | Number:Temperature | Return water temperature | R |
| outsidetemp | Number:Temperature | Outside temperature | R/W |
| waterpressure | Number:Pressure | Central heating water pressure | R |
| ch_enable | Switch | Central heating enabled set at boiler | R |
| ch_enablerequested | Switch | Central heating enabled requested by thermostat | R |
| ch_enableoverride | Switch | Central heating enabled overridden at gateway | R |
| ch2_enable | Switch | Central heating 2 enabled set at boiler | R |
| ch2_enablerequested | Switch | Central heating 2 enabled requested by thermostat | R |
| ch2_enableoverride | Switch | Central heating 2 enabled overridden at gateway | R |
| ch_mode | Switch | Central heating active | R |
| dhw_enable | Switch | Domestic hot water enabled | R |
| dhw_mode | Switch | Domestic hot water active | R |
| flame | Switch | Burner active | R |
| modulevel | Number:Dimensionless | Relative modulation level | R |
| maxrelmdulevel | Number:Dimensionless | Maximum relative modulation level | R |
| fault | Switch | Fault indication | R |
| servicerequest | Switch | Service required | R |
| lockout-reset | Switch | Lockout-reset enabled | R |
| lowwaterpress | Switch | Low water pressure fault | R |
| gasflamefault | Switch | Gas or flame fault | R |
| airpressfault | Switch | Air pressure fault | R |
| waterovtemp | Switch | Water over-temperature fault | R |
| oemfaultcode | Switch | OEM fault code | R |
| diag | Switch | Diagr / wstics indication | R |
| sendcommand | Text | Channel to send commands to the OpenTherm Gateway device | W |

## Full Example

Expand All @@ -86,6 +92,9 @@ Number:Temperature ConstantRoomSetpointOverride "Constant room setpoint override
Number:Temperature ControlSetpoint "Control setpoint [%.1f °C]" <temperature> { channel="openthermgateway:otgw:1:controlsetpoint" }
Number:Temperature ControlSetpointRequested "Control setpoint requested [%.1f °C]" <temperature> { channel="openthermgateway:otgw:1:controlsetpointrequested" }
Number:Temperature ControlSetpointOverride "Control setpoint override [%.1f °C]" <temperature> { channel="openthermgateway:otgw:1:controlsetpointoverride" }
Number:Temperature ControlSetpoint2 "Control setpoint 2 [%.1f °C]" <temperature> { channel="openthermgateway:otgw:1:controlsetpoint2" }
Number:Temperature ControlSetpoint2Requested "Control setpoint 2 requested [%.1f °C]" <temperature> { channel="openthermgateway:otgw:1:controlsetpoint2requested" }
Number:Temperature ControlSetpoint2Override "Control setpoint 2 override [%.1f °C]" <temperature> { channel="openthermgateway:otgw:1:controlsetpoint2override" }
Number:Temperature DomesticHotWaterTemperature "Domestic hot water temperature [%.1f °C]" <temperature> { channel="openthermgateway:otgw:1:dhwtemp" }
Number:Temperature DomesticHotWaterSetpoint "Domestic hot water setpoint [%.1f °C]" <temperature> { channel="openthermgateway:otgw:1:tdhwset" }
Number:Temperature DomesticHotWaterSetpointOverride "Domestic hot water setpoint override [%.1f °C]" <temperature> { channel="openthermgateway:otgw:1:overridedhwsetpoint" }
Expand All @@ -96,6 +105,9 @@ Number:Pressure CentralHeatingWaterPressure "Central heating water pressure [%.1
Switch CentralHeatingEnabled "Central heating enabled" <switch> { channel="openthermgateway:otgw:1:ch_enable" }
Switch CentralHeatingEnabledRequested "Central heating enabled requested" <switch> { channel="openthermgateway:otgw:1:ch_enablerequested" }
Switch CentralHeatingEnabledOverride "Central heating enabled override" <switch> { channel="openthermgateway:otgw:1:ch_enableoverride" }
Switch CentralHeating2Enabled "Central heating 2 enabled" <switch> { channel="openthermgateway:otgw:1:ch2_enable" }
Switch CentralHeating2EnabledRequested "Central 2 heating enabled requested" <switch> { channel="openthermgateway:otgw:1:ch2_enablerequested" }
Switch CentralHeating2EnabledOverride "Central 2 heating enabled override" <switch> { channel="openthermgateway:otgw:1:ch2_enableoverride" }
Switch CentralHeatingActive "Central heating active" <switch> { channel="openthermgateway:otgw:1:ch_mode" }
Switch DomesticHotWaterEnabled "Domestic hot water enabled" <switch> { channel="openthermgateway:otgw:1:dhw_enable" }
Switch DomesticHotWaterActive "Domestic hot water active" <switch> { channel="openthermgateway:otgw:1:dhw_mode" }
Expand Down Expand Up @@ -153,5 +165,4 @@ sitemap demo label="Main Menu" {
Switch item="Diagnostics" icon="" label="Diagnostics indication"
}
}
```
Original file line number Diff line number Diff line change
Expand Up @@ -45,10 +45,16 @@ public class OpenThermGatewayBindingConstants {
public static final String CHANNEL_CENTRAL_HEATING_WATER_SETPOINT = "controlsetpoint";
public static final String CHANNEL_REQUESTED_CENTRAL_HEATING_WATER_SETPOINT = "controlsetpointrequested";
public static final String CHANNEL_OVERRIDE_CENTRAL_HEATING_WATER_SETPOINT = "controlsetpointoverride";
public static final String CHANNEL_CENTRAL_HEATING2_WATER_SETPOINT = "controlsetpoint2";
public static final String CHANNEL_REQUESTED_CENTRAL_HEATING2_WATER_SETPOINT = "controlsetpoint2requested";
public static final String CHANNEL_OVERRIDE_CENTRAL_HEATING2_WATER_SETPOINT = "controlsetpoint2override";
public static final String CHANNEL_CENTRAL_HEATING_WATER_PRESSURE = "waterpressure";
public static final String CHANNEL_CENTRAL_HEATING_ENABLED = "ch_enable";
public static final String CHANNEL_REQUESTED_CENTRAL_HEATING_ENABLED = "ch_enablerequested";
public static final String CHANNEL_OVERRIDE_CENTRAL_HEATING_ENABLED = "ch_enableoverride";
public static final String CHANNEL_CENTRAL_HEATING2_ENABLED = "ch2_enable";
public static final String CHANNEL_REQUESTED_CENTRAL_HEATING2_ENABLED = "ch2_enablerequested";
public static final String CHANNEL_OVERRIDE_CENTRAL_HEATING2_ENABLED = "ch2_enableoverride";
public static final String CHANNEL_CENTRAL_HEATING_MODE = "ch_mode";
public static final String CHANNEL_DOMESTIC_HOT_WATER_TEMPERATURE = "dhwtemp";
public static final String CHANNEL_DOMESTIC_HOT_WATER_ENABLED = "dhw_enable";
Expand All @@ -71,8 +77,11 @@ public class OpenThermGatewayBindingConstants {
CHANNEL_FLOW_TEMPERATURE, CHANNEL_RETURN_TEMPERATURE, CHANNEL_OUTSIDE_TEMPERATURE,
CHANNEL_CENTRAL_HEATING_WATER_PRESSURE, CHANNEL_CENTRAL_HEATING_ENABLED,
CHANNEL_REQUESTED_CENTRAL_HEATING_ENABLED, CHANNEL_OVERRIDE_CENTRAL_HEATING_ENABLED,
CHANNEL_CENTRAL_HEATING_MODE, CHANNEL_CENTRAL_HEATING_WATER_SETPOINT,
CHANNEL_REQUESTED_CENTRAL_HEATING_WATER_SETPOINT, CHANNEL_OVERRIDE_CENTRAL_HEATING_WATER_SETPOINT,
CHANNEL_CENTRAL_HEATING2_ENABLED, CHANNEL_REQUESTED_CENTRAL_HEATING2_ENABLED,
CHANNEL_OVERRIDE_CENTRAL_HEATING2_ENABLED, CHANNEL_CENTRAL_HEATING_MODE,
CHANNEL_CENTRAL_HEATING_WATER_SETPOINT, CHANNEL_REQUESTED_CENTRAL_HEATING_WATER_SETPOINT,
CHANNEL_OVERRIDE_CENTRAL_HEATING_WATER_SETPOINT, CHANNEL_CENTRAL_HEATING2_WATER_SETPOINT,
CHANNEL_REQUESTED_CENTRAL_HEATING2_WATER_SETPOINT, CHANNEL_OVERRIDE_CENTRAL_HEATING2_WATER_SETPOINT,
CHANNEL_DOMESTIC_HOT_WATER_TEMPERATURE, CHANNEL_DOMESTIC_HOT_WATER_ENABLED, CHANNEL_DOMESTIC_HOT_WATER_MODE,
CHANNEL_DOMESTIC_HOT_WATER_SETPOINT, CHANNEL_FLAME, CHANNEL_RELATIVE_MODULATION_LEVEL,
CHANNEL_MAXIMUM_MODULATION_LEVEL, CHANNEL_FAULT, CHANNEL_SERVICEREQUEST, CHANNEL_REMOTE_RESET,
Expand Down
Original file line number Diff line number Diff line change
Expand Up @@ -118,6 +118,13 @@ public void handleCommand(ChannelUID channelUID, Command command) {
}
updateState(OpenThermGatewayBindingConstants.CHANNEL_OVERRIDE_CENTRAL_HEATING_ENABLED,
OnOffType.from(!gatewayCommand.getMessage().equals("0.0")));
} else if (code == GatewayCommandCode.ControlSetpoint2) {
if (gatewayCommand.getMessage().equals("0.0")) {
updateState(OpenThermGatewayBindingConstants.CHANNEL_OVERRIDE_CENTRAL_HEATING2_WATER_SETPOINT,
UnDefType.UNDEF);
}
updateState(OpenThermGatewayBindingConstants.CHANNEL_OVERRIDE_CENTRAL_HEATING2_ENABLED,
OnOffType.from(!gatewayCommand.getMessage().equals("0.0")));
}
} else {
connect();
Expand Down Expand Up @@ -274,6 +281,10 @@ private void disconnect() {
return GatewayCommandCode.ControlSetpoint;
case OpenThermGatewayBindingConstants.CHANNEL_OVERRIDE_CENTRAL_HEATING_ENABLED:
return GatewayCommandCode.CentralHeating;
case OpenThermGatewayBindingConstants.CHANNEL_OVERRIDE_CENTRAL_HEATING2_WATER_SETPOINT:
return GatewayCommandCode.ControlSetpoint2;
case OpenThermGatewayBindingConstants.CHANNEL_OVERRIDE_CENTRAL_HEATING2_ENABLED:
return GatewayCommandCode.CentralHeating2;
case OpenThermGatewayBindingConstants.CHANNEL_SEND_COMMAND:
return null;
default:
Expand Down
Original file line number Diff line number Diff line change
Expand Up @@ -40,6 +40,8 @@ private static Map<Integer, DataItem[]> createDataItemGroups() {
new DataItem(0, Msg.READ, ByteType.HIGHBYTE, DataType.FLAGS, 2, "cooling_enabled", CodeType.B),
new DataItem(0, Msg.READ, ByteType.HIGHBYTE, DataType.FLAGS, 3, "otc_active", CodeType.B),
new DataItem(0, Msg.READ, ByteType.HIGHBYTE, DataType.FLAGS, 4, "ch2_enable", CodeType.B),
new DataItem(0, Msg.READ, ByteType.HIGHBYTE, DataType.FLAGS, 4, "ch2_enablerequested", CodeType.T),
new DataItem(0, Msg.READ, ByteType.HIGHBYTE, DataType.FLAGS, 4, "ch2_enableoverride", CodeType.R),
new DataItem(0, Msg.READ, ByteType.HIGHBYTE, DataType.FLAGS, 5, "0x00:5", CodeType.B),
new DataItem(0, Msg.READ, ByteType.HIGHBYTE, DataType.FLAGS, 6, "0x00:6", CodeType.B),
new DataItem(0, Msg.READ, ByteType.HIGHBYTE, DataType.FLAGS, 7, "0x00:7", CodeType.B),
Expand Down Expand Up @@ -104,7 +106,13 @@ private static Map<Integer, DataItem[]> createDataItemGroups() {
new DataItem(6, Msg.READ, ByteType.HIGHBYTE, DataType.FLAGS, 6, "0x06:h6"),
new DataItem(6, Msg.READ, ByteType.HIGHBYTE, DataType.FLAGS, 7, "0x06:h7") });
g.put(7, new DataItem[] { new DataItem(7, Msg.WRITE, ByteType.BOTH, DataType.FLOAT, 0, "0x07") });
g.put(8, new DataItem[] { new DataItem(8, Msg.WRITE, ByteType.BOTH, DataType.FLOAT, 0, "controlsetpoint2") });
g.put(8, new DataItem[] {
new DataItem(8, Msg.WRITE, ByteType.BOTH, DataType.FLOAT, 0, "controlsetpoint2", SIUnits.CELSIUS,
CodeType.B),
new DataItem(8, Msg.WRITE, ByteType.BOTH, DataType.FLOAT, 0, "controlsetpoint2requested",
SIUnits.CELSIUS, CodeType.T),
new DataItem(8, Msg.WRITE, ByteType.BOTH, DataType.FLOAT, 0, "controlsetpoint2override",
SIUnits.CELSIUS, CodeType.R) });
g.put(9, new DataItem[] { new DataItem(9, Msg.READ, ByteType.BOTH, DataType.FLOAT, 0, "overridesetpoint") });
g.put(10, new DataItem[] { new DataItem(10, Msg.WRITE, ByteType.HIGHBYTE, DataType.UINT8, 0, "0x0a:h"),
new DataItem(10, Msg.WRITE, ByteType.LOWBYTE, DataType.UINT8, 0, "0x0a:l") });
Expand Down
Original file line number Diff line number Diff line change
Expand Up @@ -120,6 +120,7 @@ public static GatewayCommand parse(@Nullable String code, String message) throws
c.put(GatewayCommandCode.GpioA, "0,1,2,3,4,5,6,7");
c.put(GatewayCommandCode.GpioB, "0,1,2,3,4,5,6,7");
c.put(GatewayCommandCode.SetBack, null);
c.put(GatewayCommandCode.TemperatureSensor, "O,R");
c.put(GatewayCommandCode.AddAlternative, null);
c.put(GatewayCommandCode.DeleteAlternative, null);
c.put(GatewayCommandCode.UnknownID, null);
Expand All @@ -131,7 +132,9 @@ public static GatewayCommand parse(@Nullable String code, String message) throws
c.put(GatewayCommandCode.SetpointWater, null);
c.put(GatewayCommandCode.MaximumModulation, null);
c.put(GatewayCommandCode.ControlSetpoint, null);
c.put(GatewayCommandCode.ControlSetpoint2, null);
c.put(GatewayCommandCode.CentralHeating, "0,1");
c.put(GatewayCommandCode.CentralHeating2, "0,1");
c.put(GatewayCommandCode.VentilationSetpoint, null);
c.put(GatewayCommandCode.Reset, null);
c.put(GatewayCommandCode.IgnoreTransition, "0,1");
Expand Down
Loading