Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

[BUG] CPU Graph shows 0°C Temperature (AMD Ryzen) #80

Closed
lodriguez opened this issue Apr 15, 2024 · 19 comments
Closed

[BUG] CPU Graph shows 0°C Temperature (AMD Ryzen) #80

lodriguez opened this issue Apr 15, 2024 · 19 comments
Assignees
Labels
bug Something isn't working

Comments

@lodriguez
Copy link

Current Behavior

CPU Graph shows 0°C temperature

Expected Behavior

Show the actual temperature

Steps To Reproduce

AMD Ryzen 5800X3D
Asus Rog Strix B550-F gaming (nct6775)

Screenshots

https://i.imgur.com/c9QEOp7.png

Logs

-

Versions

- Widget: 3.0.0-RC1
- KDE Plasma: 6.0.3
- KDE Framework: 6.1.0

Additional context

It probably just uses the wrong sensor. Would be nice to have an "advanced option" where we could select a sensor.

@lodriguez lodriguez added the bug Something isn't working label Apr 15, 2024
@orblazer
Copy link
Owner

Hello,
Currently i use Maximum CPU Temperature on All CPU but maybe you haven't enable temps or something else.

  1. Could you check on System Monitor app what sensors you have for CPU temperatures ?
  2. Could you run sensors cmd and past the result ?

Thanks.

@lodriguez
Copy link
Author

I personally use zenpower, but that isn't in the Kernel. TS10_TEMP from nct6775 would be the desired sensor. It's the same as k10temp or Tdie from zenpower.

sensors.txt

@orblazer
Copy link
Owner

Hum,
Can you check if you have some sensors visible in System Monitor app ? if not i think i need to make some big changes to support that kind of package.

@lodriguez
Copy link
Author

What do you mean? Everything in sensors is visible in System Monitor.

@orblazer
Copy link
Owner

orblazer commented Apr 17, 2024

Sorry i have totally forgeot to tell you the step you can follow 🤦

This is the step for retrieve sensors for temperature :

  1. Create an new page in app
  2. search different temperature related sensors in CPU section
  3. save the page with select sensors
  4. share the file of that page (stored in ~/.local/share/plasma-systemmonitor/)

@lodriguez
Copy link
Author

That's the problem, everything in the CPU Section reports 0°C. That's why I use the chip on the Mainboard (nct6775). Some Asus board have this kind of behaviour. Asus uses asus-wmi-sensors, it87 or nct6775. Some boards still report using k10temp others don't…

@orblazer
Copy link
Owner

Oh ok, so i need to make an fallback and make something like i have done for network.

Could you past what you have when you run sensors -j '*-isa-*' ?
I have that with an I7-7700 and board Z170M-D3H :

{
   "coretemp-isa-0000":{
      "Adapter": "ISA adapter",
      "Package id 0":{
         "temp1_input": 34.000,
         "temp1_max": 80.000,
         "temp1_crit": 100.000,
         "temp1_crit_alarm": 0.000
      },
      "Core 0":{
         "temp2_input": 29.000,
         "temp2_max": 80.000,
         "temp2_crit": 100.000,
         "temp2_crit_alarm": 0.000
      },
      // ...
   }
}

So i think i need to check if Package id 0 exist and fallback to something else (the else is the why i ask you to past the output 😉).

@BanditSan
Copy link

BanditSan commented May 16, 2024

Is it possible to implement check if zenpower3 module is loaded and use temp values from that? Or maybe add option in CPU settings. I like use zenpower instead of ISA cause it also reports power usage.

zenpower output section in sensors

zenpower-pci-00c3
Adapter: PCI adapter
SVI2_Core:     1.44 V  
SVI2_SoC:      1.14 V  
Tdie:         +40.0°C  (high = +95.0°C)
Tctl:         +40.0°C  
SVI2_P_Core:  13.26 W  
SVI2_P_SoC:    2.02 W  
SVI2_C_Core:   9.22 A  
SVI2_C_SoC:    1.76 A

If need any more info can post it also

@orblazer
Copy link
Owner

Ok so the name is not something like coretemp-isa-xxxx so i think if only zenpower currently throw that bug we can simply add an option on CPU to pass in zenpower (or i can do automatically).

Could you tel me what is the output of sensors -j 'zenpower-pci-*' (you can trunk it like i have done in my last comment 😉), the output in json format is more easier to me to to implement in code.

@BanditSan
Copy link

I think problem is for systems that do not have zenpower module. Coretemp on Intel cpu's will have name like coretemp-isa-xxxx. Zenpower name is zenpower-pci-xxxx and even last 4 letters might be same on different cpu's. If you compare my sensors output and @lodriguez output it's zenpower-pci-00c3. He has 5800X3D and i have 5700G. But i guess safest is go zenpower-pci-xxxx name

sensors -j 'zenpower-pci-*'

{
   "zenpower-pci-00c3":{
      "Adapter": "PCI adapter",
      "SVI2_Core":{
         "in1_input": 1.438
      },
      "SVI2_SoC":{
         "in2_input": 1.144
      },
      "Tdie":{
         "temp1_input": 46.000,
         "temp1_max": 95.000
      },
      "Tctl":{
         "temp2_input": 46.000
      },
      "SVI2_P_Core":{
         "power1_input": 16.981
      },
      "SVI2_P_SoC":{
         "power2_input": 3.029
      },
      "SVI2_C_Core":{
         "curr1_input": 11.858
      },
      "SVI2_C_SoC":{
         "curr2_input": 2.648
      }
   }
}

Without zenpower CPU temp provided by k10temp upstream kernel module. On my system it is acting weird and do not appear in sensors unless i load module with force=1 option.

sensors -j 'k10temp-pci-*'

{
   "k10temp-pci-00c3":{
      "Adapter": "PCI adapter",
      "Tctl":{
         "temp1_input": 39.625
      }
   }
}

That's the problem, everything in the CPU Section reports 0°C. That's why I use the chip on the Mainboard (nct6775). Some Asus board have this kind of behaviour. Asus uses asus-wmi-sensors, it87 or nct6775. Some boards still report using k10temp others don't…

nct6775 is kernel module for motherboards sensor not CPU's. Name in sensors will depend what sensors chip is on the board.

nct6775: Found NCT6798D or compatible chip at 0x2e:0x290

Me and @lodriguez we both have Asus mb just different model so chip is same. But for diferent board manufacturer name might be something like nctxxxx-isa-xxx or even *-isa-xxx

sensors -j 'nct6798-isa-*'

{
   "nct6798-isa-0290":{
      "Adapter": "ISA adapter",
      "in0":{
         "in0_input": 0.536,
         "in0_min": 0.000,
         "in0_max": 1.744,
         "in0_alarm": 0.000,
         "in0_beep": 0.000
      },
      "in1":{
         "in1_input": 1.000,
         "in1_min": 0.000,
         "in1_max": 0.000,
         "in1_alarm": 1.000,
         "in1_beep": 0.000
      },
      "in2":{
         "in2_input": 3.376,
         "in2_min": 0.000,
         "in2_max": 0.000,
         "in2_alarm": 1.000,
         "in2_beep": 0.000
      },
      "in3":{
         "in3_input": 3.312,
         "in3_min": 0.000,
         "in3_max": 0.000,
         "in3_alarm": 1.000,
         "in3_beep": 0.000
      },
      "in4":{
         "in4_input": 0.992,
         "in4_min": 0.000,
         "in4_max": 0.000,
         "in4_alarm": 1.000,
         "in4_beep": 0.000
      },
      "in5":{
         "in5_input": 0.920,
         "in5_min": 0.000,
         "in5_max": 0.000,
         "in5_beep": 0.000
      },
      "in6":{
         "in6_input": 0.248,
         "in6_min": 0.000,
         "in6_max": 0.000,
         "in6_alarm": 1.000,
         "in6_beep": 0.000
      },
      "in7":{
         "in7_input": 3.376,
         "in7_min": 0.000,
         "in7_max": 0.000,
         "in7_alarm": 1.000,
         "in7_beep": 0.000
      },
      "in8":{
         "in8_input": 3.296,
         "in8_min": 0.000,
         "in8_max": 0.000,
         "in8_alarm": 1.000,
         "in8_beep": 0.000
      },
      "in9":{
         "in9_input": 1.808,
         "in9_min": 0.000,
         "in9_max": 0.000,
         "in9_alarm": 1.000,
         "in9_beep": 0.000
      },
      "in10":{
         "in10_input": 0.640,
         "in10_min": 0.000,
         "in10_max": 0.000,
         "in10_alarm": 1.000,
         "in10_beep": 0.000
      },
      "in11":{
         "in11_input": 2.048,
         "in11_min": 0.000,
         "in11_max": 0.000,
         "in11_alarm": 1.000,
         "in11_beep": 0.000
      },
      "in12":{
         "in12_input": 1.032,
         "in12_min": 0.000,
         "in12_max": 0.000,
         "in12_alarm": 1.000,
         "in12_beep": 0.000
      },
      "in13":{
         "in13_input": 0.360,
         "in13_min": 0.000,
         "in13_max": 0.000,
         "in13_alarm": 1.000,
         "in13_beep": 0.000
      },
      "in14":{
         "in14_input": 0.264,
         "in14_min": 0.000,
         "in14_max": 0.000,
         "in14_alarm": 1.000,
         "in14_beep": 0.000
      },
      "fan1":{
         "fan1_input": 791.000,
         "fan1_min": 0.000,
         "fan1_alarm": 0.000,
         "fan1_beep": 0.000,
         "fan1_pulses": 2.000
      },
      "fan2":{
         "fan2_input": 1032.000,
         "fan2_min": 0.000,
         "fan2_alarm": 0.000,
         "fan2_beep": 0.000,
         "fan2_pulses": 2.000
      },
      "fan3":{
         "fan3_input": 846.000,
         "fan3_min": 0.000,
         "fan3_alarm": 0.000,
         "fan3_beep": 0.000,
         "fan3_pulses": 2.000
      },
      "fan4":{
         "fan4_input": 877.000,
         "fan4_min": 0.000,
         "fan4_alarm": 0.000,
         "fan4_beep": 0.000,
         "fan4_pulses": 2.000
      },
      "fan5":{
         "fan5_input": 0.000,
         "fan5_min": 0.000,
         "fan5_alarm": 0.000,
         "fan5_beep": 0.000,
         "fan5_pulses": 2.000
      },
      "fan6":{
         "fan6_input": 0.000,
         "fan6_min": 0.000,
         "fan6_alarm": 0.000,
         "fan6_pulses": 2.000
      },
      "fan7":{
         "fan7_input": 996.000,
         "fan7_min": 0.000,
         "fan7_pulses": 2.000
      },
      "SYSTIN":{
         "temp1_input": 30.000,
         "temp1_max": 80.000,
         "temp1_max_hyst": 75.000,
         "temp1_crit": 125.000,
         "temp1_alarm": 0.000,
         "temp1_type": 4.000,
         "temp1_offset": 0.000,
         "temp1_beep": 0.000
      },
      "CPUTIN":{
         "temp2_input": 31.500,
         "temp2_max": 80.000,
         "temp2_max_hyst": 75.000,
         "temp2_crit": 125.000,
         "temp2_alarm": 0.000,
         "temp2_type": 4.000,
         "temp2_offset": 0.000,
         "temp2_beep": 0.000
      },
      "AUXTIN0":{
         "temp3_input": 85.000,
         "temp3_max": 80.000,
         "temp3_max_hyst": 75.000,
         "temp3_crit": 125.000,
         "temp3_alarm": 1.000,
         "temp3_type": 4.000,
         "temp3_offset": 0.000,
         "temp3_beep": 0.000
      },
      "AUXTIN1":{
         "temp4_input": 47.000,
         "temp4_max": 80.000,
         "temp4_max_hyst": 75.000,
         "temp4_crit": 125.000,
         "temp4_alarm": 0.000,
         "temp4_type": 4.000,
         "temp4_offset": 0.000,
         "temp4_beep": 0.000
      },
      "AUXTIN2":{
         "temp5_input": -62.000,
         "temp5_max": 80.000,
         "temp5_max_hyst": 75.000,
         "temp5_crit": 100.000,
         "temp5_alarm": 0.000,
         "temp5_type": 4.000,
         "temp5_offset": 0.000,
         "temp5_beep": 0.000
      },
      "AUXTIN3":{
         "temp6_input": 80.000,
         "temp6_max": 80.000,
         "temp6_max_hyst": 75.000,
         "temp6_crit": 100.000,
         "temp6_alarm": 1.000,
         "temp6_type": 4.000,
         "temp6_offset": 0.000,
         "temp6_beep": 0.000
      },
      "AUXTIN4":{
         "temp7_input": 30.000,
         "temp7_max": 80.000,
         "temp7_max_hyst": 75.000,
         "temp7_crit": 100.000,
         "temp7_alarm": 0.000,
         "temp7_beep": 0.000
      },
      "PECI Agent 0 Calibration":{
         "temp8_input": 43.000,
         "temp8_max": 80.000,
         "temp8_max_hyst": 75.000,
         "temp8_beep": 0.000
      },
      "PCH_CHIP_CPU_MAX_TEMP":{
         "temp9_input": 0.000
      },
      "PCH_CHIP_TEMP":{
         "temp10_input": 0.000
      },
      "PCH_CPU_TEMP":{
         "temp11_input": 0.000
      },
      "PCH_MCH_TEMP":{
         "temp12_input": 0.000
      },
      "TSI0_TEMP":{
         "temp13_input": 54.000
      },
      "intrusion0":{
         "intrusion0_alarm": 1.000,
         "intrusion0_beep": 0.000
      },
      "intrusion1":{
         "intrusion1_alarm": 1.000,
         "intrusion1_beep": 0.000
      },
      "beep_enable":{
         "beep_enable": 0.000
      }
   }
}

Ok so the name is not something like coretemp-isa-xxxx so i think if only zenpower currently throw that bug we can simply add an option on CPU to pass in zenpower (or i can do automatically).

Auto or option is up to you but it's always nice to have more options :)
On Arch if you install zenpower-dkms package it blacklists upstream k10temp module from loading. Might be similar on other distros. For auto i guess 1st check for zenpower, 2nd for k10temp and maybe as 3rd option go for MB sensor. MB sensor is a bit unreliable and reports lower values compared to zenpower or k10temp and as mentioned above naming might be all over the place depending on the MB.

@orblazer
Copy link
Owner

Thank for all informations,

And in finally i can simply fallback to zenpower if the official sensor (cpu/all/maximumTemperature) return null value due it's currently only support coretemp and k10temp (src: https://invent.kde.org/plasma/ksystemstats/-/blob/master/plugins/cpu/linuxcpuplugin.cpp?ref_type=heads#L162).

I think is useless to add complexity to that, and i don't see how can have none of zenpower or k10temp enabled.

@BanditSan
Copy link

I guess plasma supports only official coretemp and k10temp modules from kernel. zenpower and zenpower3 are 3rd party modules. There was discussion about upstreaming zenpower3 code to kernel, but it never happened. zenpower3 for me much better module since it provides more info fompared to k10temp

k10temp-pci-00c3
Adapter: PCI adapter
Tctl:         +39.4°C
zenpower-pci-00c3
Adapter: PCI adapter
SVI2_Core:     1.43 V  
SVI2_SoC:      1.14 V  
Tdie:         +44.8°C  (high = +95.0°C)
Tctl:         +44.8°C  
SVI2_P_Core:  15.02 W  
SVI2_P_SoC:    2.36 W  
SVI2_C_Core:  10.54 A  
SVI2_C_SoC:    2.06 A

@orblazer
Copy link
Owner

Hello,
Could you try the fix with the unreleased version ?

For that you have to download repo and choose 1 of bellow options :

  • run ./scripts/test.sh (require have plasma-sdk installed)
  • copy package folder in ~/.local/share/plasma/plasmoids/org.kde.plasma.resources-monitor/, and restart plasma shell (with killall plasmashell; kstart plasmashell or logout/login)

Thanks.

@BanditSan
Copy link

Something is still not working right. Temp shows up for second after enable and goes back to 0

Short demo

2024-05-22.20-49-47.mp4

@orblazer
Copy link
Owner

if you keep it enabled it's stuck to 0 ? I think i have an issue with my fallback detection method, or it's because "official" sensor return non zero value.

Can you edit the bellow file and add console.log(status, value) before that line ?

if (typeof value !== "undefined" && status === 2) {

@BanditSan
Copy link

After enabling temp console output

qt.svg.draw: The requested filter buffer is too big, ignoring
qml: 0 undefined
qml: 2 0
qml: 2 0
qml: 2 0
qml: 2 0
qml: 2 0
qml: 2 0
qml: 2 0
qml: 2 0
qml: 2 0
qml: 2 0
qml: 2 0

@orblazer
Copy link
Owner

OH oki i doesn't know if the sensor pass in ready status, so i will fix it in few hours.

orblazer added a commit that referenced this issue May 22, 2024
@orblazer
Copy link
Owner

You can try with new version ;)

@BanditSan
Copy link

Now seem to be working fine.

Screenshot_20240523_195606

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment