pygruenbeck_cloud
is a Python 3 (>= 3.11) library to communicate with the Grünbeck Cloud based Water softeners.
It is intended to be used in custom_component hagruenbeck_cloud for Home Assistant.
Implementation is based on the ioBroker gruenbeck adapter implementation.
Parameter | Type | Description |
---|---|---|
dslt | boolean | Activation of daylight saving time |
buzzer | boolean | Activation of signal on error |
buzzer_from | time (HH:MM) | Signal from time |
buzzer_to | time (HH:MM) | Signal from time |
push_notification | boolean | Activation of push notifications |
email_notification | boolean | Activation of email notifications |
water_hardness_unit | integer | Water hardness Unit (1 = "°dH", 2 = "°fH", 3 = "°e", 4 = "mol/m³", 5 = "ppm") |
raw_water_hardness | integer | Water hardness value |
soft_water_hardness | integer | Softwater hardness value |
mode | integer | Current operation mode (1 = "Eco", 2 = "Comfort", 3 = "Power", 4 = "Individual") |
mode_individual_monday | integer | Individual mode for Monday |
mode_individual_tuesday | integer | Individual mode for Tuesday |
mode_individual_wednesday | integer | Individual mode for Wednesday |
mode_individual_thursday | integer | Individual mode for Thursday |
mode_individual_friday | integer | Individual mode for Friday |
mode_individual_saturday | integer | Individual mode for Saturday |
mode_individual_sunday | integer | Individual mode for Sunday |
regeneration_mode | integer | Regeneration mode (0 = "Auto", 1 = "Fixed") |
regeneration_time_monday_1 | string | Custom regeneration time for Monday 1 (Format: HH:MM) |
regeneration_time_monday_2 | string | Custom regeneration time for Monday 2 (Format: HH:MM) |
regeneration_time_monday_3 | string | Custom regeneration time for Monday 3 (Format: HH:MM) |
regeneration_time_tuesday_1 | string | Custom regeneration time for Tuesday 1 (Format: HH:MM) |
regeneration_time_tuesday_2 | string | Custom regeneration time for Tuesday 2 (Format: HH:MM) |
regeneration_time_tuesday_3 | string | Custom regeneration time for Tuesday 3 (Format: HH:MM) |
regeneration_time_wednesday_1 | string | Custom regeneration time for Wednesday 1 (Format: HH:MM) |
regeneration_time_wednesday_2 | string | Custom regeneration time for Wednesday 2 (Format: HH:MM) |
regeneration_time_wednesday_3 | string | Custom regeneration time for Wednesday 3 (Format: HH:MM) |
regeneration_time_thursday_1 | string | Custom regeneration time for Thursday 1 (Format: HH:MM) |
regeneration_time_thursday_2 | string | Custom regeneration time for Thursday 2 (Format: HH:MM) |
regeneration_time_thursday_3 | string | Custom regeneration time for Thursday 3 (Format: HH:MM) |
regeneration_time_friday_1 | string | Custom regeneration time for Friday 1 (Format: HH:MM) |
regeneration_time_friday_2 | string | Custom regeneration time for Friday 2 (Format: HH:MM) |
regeneration_time_friday_3 | string | Custom regeneration time for Friday 3 (Format: HH:MM) |
regeneration_time_saturday_1 | string | Custom regeneration time for Saturday 1 (Format: HH:MM) |
regeneration_time_saturday_2 | string | Custom regeneration time for Saturday 2 (Format: HH:MM) |
regeneration_time_saturday_3 | string | Custom regeneration time for Saturday 3 (Format: HH:MM) |
regeneration_time_sunday_1 | string | Custom regeneration time for Sunday 1 (Format: HH:MM) |
regeneration_time_sunday_2 | string | Custom regeneration time for Sunday 2 (Format: HH:MM) |
regeneration_time_sunday_3 | string | Custom regeneration time for Sunday 3 (Format: HH:MM) |
maintenance_interval | integer | Maintenance interval in days |
installer_name | string | Installer name |
installer_phone | string | Installer phone |
installer_email | string | Installer email |
ntp_sync | bool | Get date/time automatically (NTP) |
fault_signal_contact | bool | Function fault signal contact |
knx | bool | KNX connection |
nominal_flow_monitoring | bool | Monitoring of nominal flow |
disinfection_monitoring | bool | Disinfection monitoring |
led_ring_mode | int | Illuminated LED ring mode (0 = "deactivated", 1 = "permanent lightning", 2 = "in case of failure", 3 = "in case of operation by user + failure", 4 = "in case of water treatment + operation by user + failure") |
led_ring_flash_on_signal | bool | Illuminated LED ring flashes for pre-alarm salt supply |
led_ring_brightness | int | LED ring Brightness [%] |
residual_capacity_limit | int | Residual capacity limit value [%] |
current_setpoint | int | Current setpoint [mA] |
charge | int | Charge [mAmin] |
interval_forced_regeneration | int | Interval of forced regeneration [days] |
end_frequency_regeneration_valve | int | End frequency regeneration valve [Hz] |
end_frequency_regeneration_valve_2 | int | End frequency regeneration valve 2 [Hz] |
end_frequency_blending_valve | int | End frequency blending valve [Hz] |
treatment_volume | int | Treatment volume [m³] |
soft_water_meter_pulse_rate | float | Soft water meter pulse rate [l/Imp] |
blending_water_meter_pulse_rate | float | Blending water meter pulse rate [l/Imp] |
regeneration_water_meter_pulse_rate | float | Regeneration water meter pulse rate [l/Imp] |
capacity_figure_monday | int | Capacity figure Monday [m³x°dH] |
capacity_figure_tuesday | int | Capacity figure Tuesday [m³x°dH] |
capacity_figure_wednesday | int | Capacity figure Wednesday [m³x°dH] |
capacity_figure_thursday | int | Capacity figure Thursday [m³x°dH] |
capacity_figure_friday | int | Capacity figure Friday [m³x°dH] |
capacity_figure_saturday | int | Capacity figure Saturday [m³x°dH] |
capacity_figure_sundday | int | Capacity figure Sunday [m³x°dH] |
nominal_flow_rate | float | Nominal flow rate [m³/h] |
regeneration_monitoring_time | int | Regeneration monitoring time [min] |
salting_monitoring_time | int | Salting monitoring time [min] |
slow_rinse | float | Slow rinse [min] |
backwash | int | Backwash [l] |
washing_out | int | Washing out [l] |
minimum_filling_volume_smallest_cap | float | Minimum filling volume smallest cap [l] |
maximum_filling_volume_smallest_cap | float | Maximum filling volume smallest cap [l] |
minimum_filling_volume_largest_cap | float | Minimum filling volume largest cap [l] |
maximum_filling_volume_largest_cap | float | Maximum filling volume largest cap [l] |
longest_switch_on_time_chlorine_cell | int | Longest switch-on time Cl cell [min] |
maximum_remaining_time_regeneration | int | Maximum remaining time regeneration [min] |
language | int | Current language (1 = "German", 2 = "English", 3 = "French", 4 = "Italian", 5 = "Dutch", 6 = "Spanish", 7 = "Russian", 9 = "Danish") |
programmable_output_function | int | Programmable output function |
programmable_input_function | int | Programmable input function |
reaction_to_power_failure | int | Reaction to power failure > 5 min |
chlorine_cell_mode | int | Activate/deactivate chlorine cell |
blending_monitoring | int | Blending monitoring |
system_overloaded | int | System overloaded |
And these are additional parameter which are provided by the API, but their meaning and/or value is not known:
Parameter | Type |
---|---|
ppressurereg | int |
Feel free to open an issue if you know the meaning of them and their possible values.