LED numbers on schematic and silkscreen, UART silkscreen labels #13

Merged
merged 2 commits into from
May 7, 2012

Conversation

scdwyer
Copy link
Contributor

@scdwyer scdwyer commented May 7, 2012

Changed LED numbering in schematic to go from 1-5 then 6-8 correspond to the alternate LEDs (normally ADC1-3)

Also swapped UART1/3 silkscreen labels and analog1/2 connector labels to keep consistency with software and lisa/m v1.0 as per issue #9.

…kscreen

 - changed LED labels on schematic to be more intuitive and match software defines
 - changed power led to LEDVIN from LED4 (can't be controlled) in schematic
 - changed LED silkscreen label numbers to match new schematic labels
@esden esden merged commit 436334f into paparazzi:master May 7, 2012