Baseline firmware for the Warp family of hardware platforms
This is the firmware for the Warp hardware and its publicly available and unpublished derivatives. This firmware also runs on the Freescale/NXP FRDM KL03 evaluation board which we use for teaching at the University of Cambridge. When running on platforms other than Warp, only the sensors available in the corresponding hardware platform are accessible.
Prerequisites: You need an arm cross-compiler such as arm-none-eabi-gcc
installed as well as a working cmake
(installed, e.g., via apt-get
on Linux or via MacPorts on macOS). On Ubuntu, the package you need is gcc-arm-none-eabi
. You will also need an installed copy of the SEGGER JLink commander, JlinkExe
, which is available for Linux, macOS, and Windows (here are direct links for downloading it for macOS, and Linux tgz 64-bit).
First, edit setup.conf to set the variable ARMGCC_DIR
and JLINKPATH
. If your arm-none-eabi-gcc
is in /usr/local/bin/arm-none-eabi-gcc
, then you want to set ARMGCC_DIR
to /usr/local
. In the following, this README.md
will refer to the top of the repository as $TREEROOT
. On some platforms, you might need to also, in addition, set the ARMGCC_DIR
environment variable in your shell (using setenv
or export
as appropriate), to point to the same path as you set in setup.conf.
Second, edit tools/scripts/glaux.jlink.commands
and tools/scripts/warp.jlink.commands
to replace <full-path-to-warp-firmware>
with the full path to your Warp firmware directory.
Third, build the Warp firmware by
make warp
Fourth, load the Warp firmware to hardware by
make load-warp
To build for the Glaux variant, use make glaux
and make load-glaux
in steps three and four instead.
The build process copies files from src/boot/ksdk1.1.0/
into the build/
, builds, and converts the binary to SREC. See Warp/src/boot/ksdk1.1.0/README.md
for more. When editing source, edit the files in src/boot/ksdk1.1.0/
, not the files in build
location, since the latter are overwritten during each build.
To connect to the running hardware to see output, you will need two terminal windows. In a separate shell window from the one in which you ran make load-warp
(or its variants), launch the JLink RTT client See note 1 below:
JLinkRTTClient
The SEGGER firmware allows you to use SEGGER’s JLink software to load your own firmware to the board, even without using their specialized JLink programming cables. You can find the SEGGER firmware at the SEGGER Page for OpenSDA firmware.
To build the Warp firmware for the FRDM KL03, you will need to modify this line in src/boot/ksdk1.1.0/config.h
.
The firmware is currently all in src/boot/ksdk1.1.0/
, in particular, see src/boot/ksdk1.1.0/warp-kl03-ksdk1.1-boot.c
and the per-sensor drivers in src/boot/ksdk1.1.0/dev*.[c,h]
.
The firmware builds on the Kinetis SDK. You can find more documentation on the Kinetis SDK in the document doc/Kinetis SDK v.1.1 API Reference Manual.pdf.
The firmware is designed for the Warp and Glaux hardware platforms, but will also run on the Freescale FRDM KL03 development board. In that case, the only sensor driver which is relevant is the one for the MMA8451Q. For more details about the structure of the firmware, see src/boot/ksdk1.1.0/README.md.
When the firmware boots, you will be dropped into a menu with a rich set of commands. The Warp boot menu allows you to conduct most of the experiments you will likely need without modifying the firmware:
[ * W a r p (rev. b) * ]
[ Cambridge / Physcomplab ]
Supply=0mV, Default Target Read Register=0x00
I2C=200kb/s, SPI=200kb/s, UART=1kb/s, I2C Pull-Up=32768
SIM->SCGC6=0x20000001 RTC->SR=0x10 RTC->TSR=0x5687132B
MCG_C1=0x42 MCG_C2=0x00 MCG_S=0x06
MCG_SC=0x00 MCG_MC=0x00 OSC_CR=0x00
SMC_PMPROT=0x22 SMC_PMCTRL=0x40 SCB->SCR=0x00
PMC_REGSC=0x00 SIM_SCGC4=0xF0000030 RTC->TPR=0xEE9
0s in RTC Handler to-date, 0 Pmgr Errors
Select:
- 'a': set default sensor.
- 'b': set I2C baud rate.
- 'c': set SPI baud rate.
- 'd': set UART baud rate.
- 'e': set default register address.
- 'f': write byte to sensor.
- 'g': set default SSSUPPLY.
- 'h': powerdown command to all sensors.
- 'i': set pull-up enable value.
- 'j': repeat read reg 0x00 on sensor #3.
- 'k': sleep until reset.
- 'l': send repeated byte on I2C.
- 'm': send repeated byte on SPI.
- 'n': enable SSSUPPLY.
- 'o': disable SSSUPPLY.
- 'p': switch to VLPR mode.
- 'r': switch to RUN mode.
- 's': power up all sensors.
- 't': dump processor state.
- 'u': set I2C address.
- 'x': disable SWD and spin for 10 secs.
- 'z': dump all sensors data.
Enter selection>
By default on Unix, you will likely see characters you enter shown twice. To avoid this, do the following:
- Make sure you are running
bash
(and notcsh
) - Execute
stty -echo
at the command line in the terminal window in which you will run theJLinkRTTClient
.
You can probe around the menu to figure out what to do. In brief, you will likely want:
-
Menu item
b
to set the I2C baud rate. -
Menu item
r
to switch the processor from low-power mode (2MHz) to "run" mode (48MHz). -
Menu item
g
to set sensor supply voltage. -
Menu item
n
to turn on the voltage regulators. -
Menu item
z
to repeatedly read from all the sensors whose drivers are compiled into the build.
NOTE: In many cases, the menu expects you to type a fixed number of characters (e.g., 0000 or 0009 for zero and nine) See note 1 below. If using the JLinkRTTClient
, the menu interface eats your characters as you type them, and you should not hit RETURN after typing in text. On the other hand, if using telnet
you have to hit return.
If you see repeated characters, you can set your terminal to not echo typed characters using stty -echo
.
b
(set the I2C baud rate to0300
for 300 kb/s).g
(set sensor supply voltage to3000
for 3000mV sensor supply voltage).n
(turn on the sensor supply regulators).j
(submenu for initiating a fixed number of repeated reads from a sensor):
Enter selection> j
Auto-increment from base address 0x01? ['0' | '1']> 0
Chunk reads per address (e.g., '1')> 1
Chatty? ['0' | '1']> 1
Inter-operation spin delay in milliseconds (e.g., '0000')> 0000
Repetitions per address (e.g., '0000')> 0000
Maximum voltage for adaptive supply (e.g., '0000')> 2500
Reference byte for comparisons (e.g., '3e')> 00
This will perpetually stream data from the 90+ sensor dimensions at a rate of about 90-tuples per second. Use the following command sequence:
b
(set the I2C baud rate to0300
for 300 kb/s).r
(enable 48MHz "run" mode for the processor).g
(set sensor supply voltage to3000
for 3000mV sensor supply voltage).n
(turn on the sensor supply regulators).z
(start to stream data from all sensors that can run at the chosen voltage and baud rate).
From your local clone:
git remote add upstream https://github.com/physical-computation/Warp-firmware.git
git fetch upstream
git pull upstream master
Phillip Stanley-Marbell and Martin Rinard. “A Hardware Platform for Efficient Multi-Modal Sensing with Adaptive Approximation”. ArXiv e-prints (2018). arXiv:1804.09241.
BibTeX:
@ARTICLE{1804.09241,
author = {Stanley-Marbell, Phillip and Rinard, Martin},
title = {A Hardware Platform for Efficient Multi-Modal
Sensing with Adaptive Approximation},
journal = {ArXiv e-prints},
archivePrefix = {arXiv},
eprint = {1804.09241},
year = 2018,
}
Phillip Stanley-Marbell and Martin Rinard. “Warp: A Hardware Platform for Efficient Multi-Modal Sensing with Adaptive Approximation”. IEEE Micro, Volume 40 , Issue 1 , Jan.-Feb. 2020.
BibTeX:
@ARTICLE{8959350,
author = {P. {Stanley-Marbell} and M. {Rinard}},
title = {Warp: A Hardware Platform for Efficient Multi-Modal
Sensing with Adaptive Approximation},
journal = {IEEE Micro},
year = {2020},
volume = {40},
number = {1},
pages = {57-66},
ISSN = {1937-4143},
month = {Jan},
}
This research is supported by an Alan Turing Institute award TU/B/000096 under EPSRC grant EP/N510129/1, by Royal Society grant RG170136, and by EPSRC grants EP/P001246/1 and EP/R022534/1.
1 On some Unix platforms, the JLinkRTTClient
has a double echo of characters you type in. You can prevent this by configuring your terminal program to not echo the characters you type. To achieve this on bash
, use stty -echo
from the terminal. Alternatively, rather than using the JLinkRTTClient
, you can use a telnet
program: telnet localhost 19021