Showing 1 changed file with 18 additions and 18 deletions.
36 changes: 18 additions & 18 deletions docs/grid_exchange_formats/cgmes/export.md
Original file line number Diff line number Diff line change
Expand Up @@ -183,10 +183,10 @@ Imported CGMES `RegulatingControl` for `Generator` is always exported.

`RegulatingControl` is not exported when `Generator` has no regulation capability `minQ=maxQ`.

`RegulatingControl` is exported with `RegulatingControl.mode=RegulatingControlModeKind.reactivePower` when
`Generator->RemoteReactivePowerControl.enabled=true` and `Generator->voltageRegulatorOn=false`
`RegulatingControl` is exported with `RegulatingControl.mode` set to `RegulatingControlModeKind.reactivePower` when
`Generator` with `RemoteReactivePowerControl.enabled` set to `true` and `Generator` `voltageRegulatorOn` set to `false`

`RegulatingControl` is exported with `RegulatingControl.mode=RegulatingControlModeKind.voltage` in all other cases.
`RegulatingControl` is exported with `RegulatingControl.mode` set to `RegulatingControlModeKind.voltage` in all other cases.

<span style="color: red">TODO details</span>

Expand Down Expand Up @@ -216,7 +216,7 @@ PowSyBl [`ShuntCompensator`](../../grid_model/network_subnetwork.md#shunt-compen
`RegulatingControl` for `ShuntCompensator` is not exported when`RegulatingTerminal` is the same as `ShuntCompensator`
Terminal (local control) and `TargetV` is not set.

In all other cases, `RegulatingControl` is exported with `RegulatingControl.mode=RegulatingControlModeKind.voltage`
In all other cases, `RegulatingControl` is exported with `RegulatingControl.mode` set to `RegulatingControlModeKind.voltage`

<span style="color: red">TODO details</span>

Expand All @@ -226,12 +226,12 @@ PowSyBl [`StaticVarCompensator`](../../grid_model/network_subnetwork.md#static-v

#### RegulatingControl export
`RegulatingControl` is not exported when `RegulatingTerminal` is the same as `StaticVarCompensator` Terminal,
`StaticVarCompensator->regulationMode=OFF` and there is not valid `voltageSetpoint` or `reactivePowerSetpoint`.
`StaticVarCompensator` is with `regulationMode` set to `OFF` and there is not valid `voltageSetpoint` or `reactivePowerSetpoint`.

`RegulatingControl` is exported with `RegulatingControl.mode=RegulatingControlModeKind.reactivePower` when
`StaticVarCompensator->regulationMode=OFF` or `StaticVarCompensator->regulationMode=REACTIVE_POWER`, `voltageSetpoint` is not valid and `reactivePowerSetpoint` is valid.
`RegulatingControl` is exported with `RegulatingControl.mode` set to `RegulatingControlModeKind.reactivePower` when
`StaticVarCompensator` is with `regulationMode` set to `OFF` or `StaticVarCompensator` with `regulationMode` set to `REACTIVE_POWER`, `voltageSetpoint` is not valid and `reactivePowerSetpoint` is valid.

`RegulatingControl` is exported with `RegulatingControl.mode=RegulatingControlModeKind.voltage` in all other cases.
`RegulatingControl` is exported with `RegulatingControl.mode` set to `RegulatingControlModeKind.voltage` in all other cases.

<span style="color: red">TODO details</span>

Expand All @@ -254,18 +254,18 @@ PowSyBl [`ThreeWindingsTransformer`](../../grid_model/network_subnetwork.md#thre
#### TapChangerControl export

`RatioTapChanger`:
- `TapChangerControl` is not exported when `RatioTapChanger->regulationMode` is not defined.
- `TapChangerControl` is exported with `RegulatingControl.mode=RegulatingControlModeKind.reactivePower` when
`RatioTapChanger->regulationMode=REACTIVE_POWER`.
- `TapChangerControl` is exported with `RegulatingControl.mode=RegulatingControlModeKind.voltage` when
`RatioTapChanger->regulationMode=VOLTAGE`.
- `TapChangerControl` is not exported when `RatioTapChanger` `regulationMode` is not defined.
- `TapChangerControl` is exported with `RegulatingControl.mode` set to `RegulatingControlModeKind.reactivePower` when
`RatioTapChanger` `regulationMode` is set to `REACTIVE_POWER`.
- `TapChangerControl` is exported with `RegulatingControl.mode` set to `RegulatingControlModeKind.voltage` when
`RatioTapChanger` `regulationMode` is set to `VOLTAGE`.

`PhaseTapChanger`
- `TapChangerControl` is not exported when `PhaseTapChanger->regulationMode=OFF`.
- `TapChangerControl` is exported with `RegulatingControl.mode=RegulatingControlModeKind.activePower` when
`PhaseTapChanger->regulationMode=ACTIVE_POWER_CONTROL`.
- `TapChangerControl` is exported with `RegulatingControl.mode=RegulatingControlModeKind.currentFlow` when
`PhaseTapChanger->regulationMode=CURRENT_LIMITER`.
- `TapChangerControl` is not exported when `PhaseTapChanger` `regulationMode` is set to `OFF`.
- `TapChangerControl` is exported with `RegulatingControl.mode` set to `RegulatingControlModeKind.activePower` when
`PhaseTapChanger` `regulationMode` is set to `ACTIVE_POWER_CONTROL`.
- `TapChangerControl` is exported with `RegulatingControl.mode` set to `RegulatingControlModeKind.currentFlow` when
`PhaseTapChanger` `regulationMode` is set to `CURRENT_LIMITER`.

<span style="color: red">TODO details</span>