Use side in Branch VarConnection #387

Merged
merged 1 commit into from
Oct 7, 2024
Merged
Show file tree
Hide file tree
Changes from all commits
Commits
File filter

Filter by extension

Filter by extension

Conversations
Failed to load comments.
Loading
Jump to
Jump to file
Failed to load files.
Loading
Diff view
Diff view
Original file line number Diff line number Diff line change
Expand Up @@ -26,7 +26,7 @@ protected StandardLine(String dynamicModelId, Line line, String parameterSetId,
}

private List<VarConnection> getVarConnectionsWith(EquipmentConnectionPoint connected, TwoSides side) {
return List.of(new VarConnection(getTerminalVarName(side), connected.getTerminalVarName()));
return List.of(new VarConnection(getTerminalVarName(side), connected.getTerminalVarName(side)));
}

private String getTerminalVarName(TwoSides side) {
Expand Down
Original file line number Diff line number Diff line change
Expand Up @@ -29,7 +29,7 @@ protected TransformerFixedRatio(String dynamicModelId, TwoWindingsTransformer tr
}

private List<VarConnection> getVarConnectionsWith(EquipmentConnectionPoint connected, TwoSides side) {
return List.of(new VarConnection(getTerminalVarName(side), connected.getTerminalVarName()));
return List.of(new VarConnection(getTerminalVarName(side), connected.getTerminalVarName(side)));
}

private String getTerminalVarName(TwoSides side) {
Expand Down
4 changes: 2 additions & 2 deletions dynawo-simulation/src/test/resources/cla_dyd.xml
Original file line number Diff line number Diff line change
Expand Up @@ -19,10 +19,10 @@
<dyn:connect var1="currentLimitAutomaton_order" var2="@NAME@_state"/>
</dyn:macroConnector>
<dyn:macroConnector id="MC_TransformerFixedRatioSide1-DefaultEquipmentConnectionPoint">
<dyn:connect var1="transformer_terminal1" var2="@STATIC_ID@@NODE@_ACPIN"/>
<dyn:connect var1="transformer_terminal1" var2="@STATIC_ID@@NODE1@_ACPIN"/>
</dyn:macroConnector>
<dyn:macroConnector id="MC_TransformerFixedRatioSide2-DefaultEquipmentConnectionPoint">
<dyn:connect var1="transformer_terminal2" var2="@STATIC_ID@@NODE@_ACPIN"/>
<dyn:connect var1="transformer_terminal2" var2="@STATIC_ID@@NODE2@_ACPIN"/>
</dyn:macroConnector>
<dyn:macroConnector id="MC_CurrentLimitAutomatonMeasureSide2-TransformerFixedRatio">
<dyn:connect var1="currentLimitAutomaton_IMonitored" var2="transformer_iSide2"/>
Expand Down
4 changes: 2 additions & 2 deletions dynawo-simulation/src/test/resources/dyd.xml
Original file line number Diff line number Diff line change
Expand Up @@ -67,10 +67,10 @@
<dyn:connect var1="generator_switchOffSignal1" var2="@STATIC_ID@@NODE@_switchOff"/>
</dyn:macroConnector>
<dyn:macroConnector id="MC_Line_NHV1_NHV2_1Side1-DefaultEquipmentConnectionPoint">
<dyn:connect var1="line_terminal1" var2="@STATIC_ID@@NODE@_ACPIN"/>
<dyn:connect var1="line_terminal1" var2="@STATIC_ID@@NODE1@_ACPIN"/>
</dyn:macroConnector>
<dyn:macroConnector id="MC_Line_NHV1_NHV2_1Side2-DefaultEquipmentConnectionPoint">
<dyn:connect var1="line_terminal2" var2="@STATIC_ID@@NODE@_ACPIN"/>
<dyn:connect var1="line_terminal2" var2="@STATIC_ID@@NODE2@_ACPIN"/>
</dyn:macroConnector>
<dyn:macroConnector id="MC_CurrentLimitAutomatonMeasureSide1-DefaultLine">
<dyn:connect var1="currentLimitAutomaton_IMonitored" var2="@NAME@_iSide1"/>
Expand Down
4 changes: 2 additions & 2 deletions dynawo-simulation/src/test/resources/phase_shifter_i_dyd.xml
Original file line number Diff line number Diff line change
Expand Up @@ -9,10 +9,10 @@
<dyn:connect var1="phaseShifter_AutomatonExists" var2="transformer_disable_internal_tapChanger"/>
</dyn:macroConnector>
<dyn:macroConnector id="MC_TransformerFixedRatioSide1-DefaultEquipmentConnectionPoint">
<dyn:connect var1="transformer_terminal1" var2="@STATIC_ID@@NODE@_ACPIN"/>
<dyn:connect var1="transformer_terminal1" var2="@STATIC_ID@@NODE1@_ACPIN"/>
</dyn:macroConnector>
<dyn:macroConnector id="MC_TransformerFixedRatioSide2-DefaultEquipmentConnectionPoint">
<dyn:connect var1="transformer_terminal2" var2="@STATIC_ID@@NODE@_ACPIN"/>
<dyn:connect var1="transformer_terminal2" var2="@STATIC_ID@@NODE2@_ACPIN"/>
</dyn:macroConnector>
<dyn:macroConnect connector="MC_PhaseShifterI-TransformerFixedRatio" id1="BBM_phase_shifter" id2="BBM_NGEN_NHV1"/>
<dyn:macroConnect connector="MC_TransformerFixedRatioSide1-DefaultEquipmentConnectionPoint" id1="BBM_NGEN_NHV1" id2="NETWORK"/>
Expand Down
Original file line number Diff line number Diff line change
Expand Up @@ -13,7 +13,7 @@
<dyn:connect var1="transformer_terminal1" var2="infiniteBus_terminal"/>
</dyn:macroConnector>
<dyn:macroConnector id="MC_TransformerFixedRatioSide2-DefaultEquipmentConnectionPoint">
<dyn:connect var1="transformer_terminal2" var2="@STATIC_ID@@NODE@_ACPIN"/>
<dyn:connect var1="transformer_terminal2" var2="@STATIC_ID@@NODE2@_ACPIN"/>
</dyn:macroConnector>
<dyn:macroConnector id="MC_SetPoint-GeneratorPQ">
<dyn:connect var1="setPoint_setPoint" var2="generator_omegaRefPu"/>
Expand Down
Original file line number Diff line number Diff line change
Expand Up @@ -9,10 +9,10 @@
</dyn:blackBoxModel>
<dyn:blackBoxModel id="BBM_TapChangerBlocking" lib="TapChangerBlockingAutomaton2" parFile="models.par" parId="TapChangerPar"/>
<dyn:macroConnector id="MC_TransformerFixedRatioSide1-DefaultEquipmentConnectionPoint">
<dyn:connect var1="transformer_terminal1" var2="@STATIC_ID@@NODE@_ACPIN"/>
<dyn:connect var1="transformer_terminal1" var2="@STATIC_ID@@NODE1@_ACPIN"/>
</dyn:macroConnector>
<dyn:macroConnector id="MC_TransformerFixedRatioSide2-DefaultEquipmentConnectionPoint">
<dyn:connect var1="transformer_terminal2" var2="@STATIC_ID@@NODE@_ACPIN"/>
<dyn:connect var1="transformer_terminal2" var2="@STATIC_ID@@NODE2@_ACPIN"/>
</dyn:macroConnector>
<dyn:macroConnector id="MC_LoadOneTransformerTapChanger-DefaultEquipmentConnectionPoint">
<dyn:connect var1="transformer_terminal1" var2="@STATIC_ID@@NODE@_ACPIN"/>
Expand Down
4 changes: 2 additions & 2 deletions dynawo-simulation/src/test/resources/tfr_dyd.xml
Original file line number Diff line number Diff line change
Expand Up @@ -2,10 +2,10 @@
<dyn:dynamicModelsArchitecture xmlns:dyn="http://www.rte-france.com/dynawo">
<dyn:blackBoxModel id="BBM_NGEN_NHV1" lib="TransformerFixedRatio" parFile="models.par" parId="TFR" staticId="NGEN_NHV1"/>
<dyn:macroConnector id="MC_TransformerFixedRatioSide1-DefaultEquipmentConnectionPoint">
<dyn:connect var1="transformer_terminal1" var2="@STATIC_ID@@NODE@_ACPIN"/>
<dyn:connect var1="transformer_terminal1" var2="@STATIC_ID@@NODE1@_ACPIN"/>
</dyn:macroConnector>
<dyn:macroConnector id="MC_TransformerFixedRatioSide2-DefaultEquipmentConnectionPoint">
<dyn:connect var1="transformer_terminal2" var2="@STATIC_ID@@NODE@_ACPIN"/>
<dyn:connect var1="transformer_terminal2" var2="@STATIC_ID@@NODE2@_ACPIN"/>
</dyn:macroConnector>
<dyn:macroConnect connector="MC_TransformerFixedRatioSide1-DefaultEquipmentConnectionPoint" id1="BBM_NGEN_NHV1" id2="NETWORK"/>
<dyn:macroConnect connector="MC_TransformerFixedRatioSide2-DefaultEquipmentConnectionPoint" id1="BBM_NGEN_NHV1" id2="NETWORK"/>