Original file line number Diff line number Diff line change
Expand Up @@ -279,7 +279,7 @@ private static <E extends Enum<E>> List<Object> getEnumPossibleValues(Class<E> e
new Parameter(SVC_VOLTAGE_MONITORING_PARAM_NAME, ParameterType.BOOLEAN, "SVC voltage monitoring", SVC_VOLTAGE_MONITORING_DEFAULT_VALUE),
new Parameter(STATE_VECTOR_SCALING_MODE_PARAM_NAME, ParameterType.STRING, "State vector scaling mode", NewtonRaphsonParameters.DEFAULT_STATE_VECTOR_SCALING_MODE.name(), getEnumPossibleValues(StateVectorScalingMode.class)),
new Parameter(MAX_SLACK_BUS_COUNT_PARAM_NAME, ParameterType.INTEGER, "Maximum slack buses count", LfNetworkParameters.DEFAULT_MAX_SLACK_BUS_COUNT),
new Parameter(DEBUG_DIR_PARAM_NAME, ParameterType.STRING, "Directory to dump debug files", LfNetworkParameters.DEBUG_DIR_DEFAULT_VALUE, Collections.emptyList(), ParameterScope.TECHNICAL),
new Parameter(DEBUG_DIR_PARAM_NAME, ParameterType.STRING, "Directory to dump debug files", LfNetworkParameters.DEBUG_DIR_DEFAULT_VALUE, null, ParameterScope.TECHNICAL),
new Parameter(INCREMENTAL_TRANSFORMER_RATIO_TAP_CONTROL_OUTER_LOOP_MAX_TAP_SHIFT_PARAM_NAME, ParameterType.INTEGER, "Incremental transformer ratio tap control maximum tap shift per outer loop", INCREMENTAL_TRANSFORMER_RATIO_TAP_CONTROL_OUTER_LOOP_MAX_TAP_SHIFT_DEFAULT_VALUE),
new Parameter(SECONDARY_VOLTAGE_CONTROL_PARAM_NAME, ParameterType.BOOLEAN, "Secondary voltage control simulation", LfNetworkParameters.SECONDARY_VOLTAGE_CONTROL_DEFAULT_VALUE),
new Parameter(REACTIVE_LIMITS_MAX_SWITCH_PQ_PV_PARAM_NAME, ParameterType.INTEGER, "Reactive limits maximum Pq Pv switch", ReactiveLimitsOuterLoop.MAX_SWITCH_PQ_PV_DEFAULT_VALUE),
Expand Down
Original file line number Diff line number Diff line change
Expand Up @@ -336,7 +336,7 @@ void testEqualsAndClone() {
newVal1 = "3";
newVal2 = "4";
} else if (sp.getType() == ParameterType.STRING) {
if (sp.getPossibleValues().isEmpty()) {
if (sp.getPossibleValues() == null) {
// e.g. debugDir
newVal1 = "Foo";
newVal2 = "Bar";
Expand All @@ -345,7 +345,7 @@ void testEqualsAndClone() {
newVal2 = sp.getPossibleValues().get(1).toString();
}
} else if (sp.getType() == ParameterType.STRING_LIST) {
if (sp.getPossibleValues() == null || sp.getPossibleValues().isEmpty()) {
if (sp.getPossibleValues() == null) {
// e.g. slackBusesIds
newVal1 = "Foo,Bar";
newVal2 = "Foo,Bar,Baz";
Expand Down