Conversation

geofjamg
Copy link
Member

@geofjamg geofjamg commented Dec 4, 2023

Please check if the PR fulfills these requirements

  • The commit message follows our guidelines
  • Tests for the changes have been added (for bug fixes / features)
  • Docs have been added / updated (for bug fixes / features)

Does this PR already have an issue describing the problem?

No

What kind of change does this PR introduce?

Bug fix

What is the current behavior?

We get a NPE when HVDC emulation is activated and we have a VSC or LCC converter station without a HVDC line.

What is the new behavior (if this is a feature change)?

Does this PR introduce a breaking change or deprecate an API?

  • Yes
  • No

If yes, please check if the following requirements are fulfilled

  • The Breaking Change or Deprecated label has been added
  • The migration steps are described in the following section

What changes might users need to make in their application due to this PR? (migration steps)

Other information:

Signed-off-by: Geoffroy Jamgotchian <geoffroy.jamgotchian@rte-france.com>
@geofjamg geofjamg requested a review from annetill December 4, 2023 15:36
@@ -78,12 +79,14 @@ public double getTargetQ() {

@Override
public double getMinP() {
return -getStation().getHvdcLine().getMaxP() / PerUnit.SB;
HvdcLine hvdcLine = getStation().getHvdcLine();
return hvdcLine != null ? -hvdcLine.getMaxP() / PerUnit.SB : -Double.MAX_VALUE;
Copy link
Member

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

It is not needed as you cannot have a VSC without any HVDC line in network loading.

Copy link
Member Author

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

I had a failing test without adding it.

Copy link
Member

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

ok, see #691 for a better solution about hvdc line.

Copy link

sonarqubecloud bot commented Dec 5, 2023

Kudos, SonarCloud Quality Gate passed!    Quality Gate passed

Bug A 0 Bugs
Vulnerability A 0 Vulnerabilities
Security Hotspot A 0 Security Hotspots
Code Smell A 0 Code Smells

85.7% 85.7% Coverage
0.0% 0.0% Duplication

@annetill annetill merged commit 0d6bbfd into main Dec 5, 2023
6 checks passed
@annetill annetill deleted the vsc_npe branch December 5, 2023 10:10