Water-Level-Meter-on-Arduino-Nano
This project shows how to
build up a water level meter with a self-made capacitive sensor based
on an Arduino Nano with only very few additional components.
Measurement values are
averaged over n cycles for stable results and normalized to 255 to fit in one Byte for
easy serial communication.
The program can be modified to get the
output as an analog value instead or additional to the serial data
output. This opens the possibility to use an analog meter to display
the water level.
Measuring principle is a capacitive voltage
divider. Two Caps in series are being charged by the "drive pin"
of the Arduino. Partial voltage along the sensor is measured then at
the "measuring pin". Very simple.
With Cref=200pf +
Csens=200pf in series, the capacity to be charged is 100pF. With an
output impedance of a digital pin of abou 100R, it takes less than
50ns.
The ADC sampling takes enough time (microseconds) to have
stable conditions. It shows very constant results with a Nano.
The
Reference Cap is between DrivePin and MeasPin. Use class 1 caps, e.g.
C0G/NP0 dielectric (stability, aging characteristics).
Choose
a Reference Cap in the Range of (min Sensor Cap. @ empty tank)*2 .
This results in ADC readings: 750 > (AdcEmpty value) > 650
(with internal analog reference). (e.g. 100-200pF as a start
value)
The Capacitive Sensor is between MeasPin (the core wire)
and GND (the tube). Wires from the Arduino to sensor should be as
short as any possible (few cm, 30cm worked fine for me).
The
sensor is e.g. a 30-70cm INOX tube with 8-10mm inner diam. with an
insulated centered drilled wire loop.
or better a INOX tube with
6mm inner diameter and a INOX (welding) wire with 1.6mm diameter well
isolated in a shrinking tube and additional sealant at the ends. Or a
rigid electrical wire, also sealed.
The wire shall be centered
well in the tube, e.g. with 2 or 4 blobs of sealant in the middle of
the wire, hardened before final assembly/insertion.
Side effect:
water drops inside the sensor, especially at oscillating water levels
may lead to slightly too high readings, decreasing after some time if
the level remain constant again.
The thinner the tube is, the
higher this side effect is.
Theory: The sensor capacity would
change by factor 80 ideally when fully immersed if there was no
measurable isolation thickness inside the sensor. In reality we can
assume an isolation.
on the inner wire of about 0.2mm for a
shrinking tube. This 0.2mm are lets say 10% of the distance between
the inner wire and the 6mm INOX tube. Its permittivity is low and
will not change.
In consequence, only the capacity of the
remaining 90% of the distance raises by factor 80 when we exchange
the air by water, but in sum the capacity will change only by about
factor 9.
This is not too bad, as we have a non-linear voltage
divider: Umeas=(Udrive/(UCref+UCsens))*UCsens. UCsens should not
approach zero or Uref here.
Empty Tank:
UmeasMax=1/(UCref+UCsensMax)*UCsensMax = 1/(0.5+1)*1 = 66% of Udrive
(Cref = 2*CsensMin).
Full Tank:
UmeasMin=1/(UCref+UCsensMin)*UCsensMin = 1/(0.5+0.11)*0.11 = 18% of
Udrive (Cref = 2*CsensMin).
As
measured values are in a "narrow" Range (e.g. 18%...66% or
184...682 of 1023 ADC digits, see above), sent values can be
stretched to (nearly) full range of 1 Byte (0...255) to keep higher
resolution.
Above values are always in this range, as most
parameters are "relative" to each other. Except e.g. the
sensor cable.
To get a usable correlation of ADC output values
with the immersion depth it is recommended to use a "polynomial
regression" calculation
The calculation of the formula can be
done e.g. with Open Office (+ CorelPolyGUI Addon) or Excel (Chart,
Add Trendline, Polynomial) . -> X-values are the Sensor ADC output
values, Y-values represent the immersion depth, volume, or else.
A
polynom of 3rd order is suitable for most applications with
sufficient accuracy, even for complex water container
shapes.
Example: float levelNormal = 265.455 - 4.31*level +
0.024*pow(float(level),2) - 0.0000445*pow(float(level),3) ; //
polynomial regression
To calculate the polynom, it is required to
measure about 10 values with your final HW setup in advance which
gives you 10 value pairs, e.g. xn=sensor value; yn=water volume
If
the calculation with the gained formula is being done on the host
computer, the "Sensor Arduino" with this program can be
housed sealed and inacessible and all
"calibrations" can
be done on the host computer. To connect to a host, just connect the TX pin
of the Arduino with the RX pin of another Arduino, an ESP or whatever.
Also connect the GNDs with each other and take care for a signal voltage
adaption if required, i.e. for ESPs.
We can use the external
reference voltage pin AREF of hte Arduino to further stretch the
analog readings for a better resolution: with an external 10k
resistor from AREF to +5V. AREF has internally about 32k to GND.
It
lowers the internal 5V ADC reference to about 3.75V and causes the
previously discussed maximum voltage UmeasMax to increase from 66% to
>90% (this is the target).
If the ext reference is wanted, this
has to be done before the calculation of the correlation of the ADC
values with the needed output like immersion depth, volume, ...
To
make use of this, find out, which resistor fits for your setup, try
with 10k as initial value to get ADC readings of 900 to 950 with a
dry sensor. This resistor is between +5V VCC and the AREF
pin.
Additionally uncomment the line
"analogReference(EXTERNAL);"
Thermal compensation might be required, if greater temperature ranges have to be served.
Temperature influence on permittivity
of water:
0°C:87.81, 10°C:83.99, 20°C:80.27,
30°C:76.67 40°C:73.22 50°C:69.90 60°C:66.73
70°C:63.70 80°C:60.81 90°C:58.05 100°C:55.41 (IAPS,
U.Grigull, München 1983)
In the range of "outdoor"
conditions it changes with ~ -0.45%/K (~ -11.3%/25K referenced to
25°C in the range of 0°C to 50°C)
As we measure
only relative values, all derived directly from the VCC, the
stability of the reference voltage is no big issue.
If supplied
with 12V, the Arduino has sufficient stability on 5V VCC.
As the
circuit allows to have the shielding sensor tube connected to GND we
also have no big problems with EMI, e.g. from cell phones or other
sources.
The concept of the program targets low energy
consumption. You can further decrease it by depopulating components
of the Arduino. First of all, the Power-LED.
But you can also
depopulate the CH340 (Nano Clone) once the program is uploaded and
you are sure everything works fine.
Modify the measuring interval
according to your needs, the maximum interval is about 8s, limited by
the Watchdog capabilities.
This is the "update frequency"
if you use the analog output. The analog signal is always
present.
This is only a suggestion, please verify everything
by yourself, I take no responsibility for any problems arising from
it. I did not test all conditions.
This project with its program and documentation is published under the rights of GNU General Public License