Remove service loop silkscreen from screen PCB #10

Closed
scottbez1 opened this issue Mar 11, 2022 · 0 comments
Closed

Remove service loop silkscreen from screen PCB #10

scottbez1 opened this issue Mar 11, 2022 · 0 comments

Comments

@scottbez1
Copy link
Owner

It's essentially impossible to align all the 30AWG wires into a service loop without overlapping, so if you actually follow the indicated silkscreen marks you'll end up with overlapping wires that are taller than the extra thin VHB tape. I found it worked better to just skip the service loops (which I don't think were usable anyway due to the tight clearances).

lgc00 pushed a commit to lgc00/smartknob that referenced this issue Jul 15, 2023
Service loops weren't really feasible/helpful, so don't recommend them via the silkscreen. Fixes scottbez1#10

Also added testpoints (or could be solder points) for all signals on the top side of the screen PCB. Fixes scottbez1#11