sv-timetamp-analysis is a tool used to analyze IEC61850 Sample Values timestamps recorded by the sv_timestamp_logger (https://github.com/seapath/sv_timestamp_logger) tool and generate a report summarizing the latencies of the SVs recorded.
- Compute various latency metrics on IEC61850 SV (pacing, latency histogram, statistics)
- Detection and correction of dropped SV
- Support of high range of SV computation
Following Python packages are needed:
pip install \
numpy \
matplotlib
First, generate IEC61850 SV data timestamps using sv_timestamp_logger tool. At least Publisher SV timestamps and subscriber SV timestamps are needed to generate a latency report. Optionally, hypervisor SV timestamps can also be used to get a measurement of latency between publisher and subscriber machines.
Then, you can run sv-timetamp-analysis tool by running:
python3 sv_timestamp_analysis.py \
--pub ts_sv_publisher.txt \
--sub ts_sv_subscriber_guest0.txt
After computation, results are available by default in current
directory in results
folder. You can override this setting using -o
argument.
A report is generated in .adoc format containing .png histogram of the SV
streams computed. On each stream, a latency threshold test is computed
based on the value of the --ttot
argument (by default, 100µs).
By default, only stream 0 is used to compute latencies. You can
override this setting using -S
or --stream
argument.
The tool is incapable to compute latencies
- if too many SV are lost between publisher and subscriber.
- if some SV are received in an different order, that the one they were sent. If you are in one of these two cases, you will encounter the error :
ValueError: files don't have the same number of iterations