You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
Input circuit arrangement for Si53340 / CLK1 (CLK0 not tested yet, but probably alike) is invalid. Termination resistor should be placed after AC decoupling capacitors. Otherwise Si53340 input bias resistors force P and N lines to have different common mode what results in no output signal.
Moving R21 after C23/C24 solves the issue.
The text was updated successfully, but these errors were encountered:
Input circuit arrangement for Si53340 / CLK1 (CLK0 not tested yet, but probably alike) is invalid. Termination resistor should be placed after AC decoupling capacitors. Otherwise Si53340 input bias resistors force P and N lines to have different common mode what results in no output signal.
Moving R21 after C23/C24 solves the issue.
The text was updated successfully, but these errors were encountered: