216 changes: 216 additions & 0 deletions doc/vxlan/Overlay ECMP with BFD.md
Original file line number Diff line number Diff line change
@@ -0,0 +1,216 @@
# Overlay ECMP with BFD monitoring
## High Level Design Document
### Rev 1.0

# Table of Contents

* [Revision](#revision)

* [About this Manual](#about-this-manual)

* [Scope](#scope)

* [Definitions/Abbreviation](#definitionsabbreviation)

* [1 Requirements Overview](#1-requirements-overview)
* [1.1 Usecase](#11-Usecase)
* [1.2 Functional requirements](#12-functional-requirements)
* [1.3 CLI requirements](#13-cli-requirements)
* [1.4 Warm Restart requirements ](#14-warm-restart-requirements)
* [2 Modules Design](#2-modules-design)
* [2.1 Config DB](#21-config-db)
* [2.2 App DB](#22-app-db)
* [2.3 Orchestration Agent](#23-orchestration-agent)
* [2.4 CLI](#24-cli)

###### Revision
| Rev | Date | Author | Change Description |
|:---:|:-----------:|:------------------:|-----------------------------------|
| 0.1 | 09/09/2021 | Prince Sunny | Initial version |

# About this Manual
This document provides general information about the Vxlan Overlay ECMP feature implementation in SONiC with BFD support. This is an extension to the existing VNET Vxlan support as defined in the [Vxlan HLD](https://github.com/Azure/SONiC/blob/master/doc/vxlan/Vxlan_hld.md)
# Scope
This document describes the high level design of the Overlay ECMP feature and associated BFD support. General BFD support and configurations are beyond the scope of this document.

# Definitions/Abbreviation
###### Table 1: Abbreviations
| | |
|--------------------------|--------------------------------|
| BFD | Bidirectional Forwarding |
prsunny marked this conversation as resolved.
Show resolved Hide resolved
| VNI | Vxlan Network Identifier |
| VTEP | Vxlan Tunnel End Point |
| VNet | Virtual Network |

# 1 Requirements Overview

## 1.1 Usecase

![](https://github.com/Azure/SONiC/blob/master/images/vxlan_hld/OverlayEcmp_UseCase.png)

## 1.1 Functional requirements

At a high level the following should be supported:

- Configure ECMP with Tunnel Nexthops (IPv4 and IPv6)
- Tunnel Endpoint monitoring via BFD
- Add/Withdraw Nexthop based on Tunnel or Endpoint health

## 1.2 CLI requirements
- User should be able to show the BFD session
prsunny marked this conversation as resolved.
Show resolved Hide resolved
- User should be able to show the Vnet routes

## 1.3 Warm Restart requirements
No special handling for Warm restart support.

# 2 Modules Design

The following are the schema changes.

## 2.1 Config DB

Existing Vxlan and Vnet tables.

### 2.1.1 VXLAN Table
```
VXLAN_TUNNEL|{{tunnel_name}}
"src_ip": {{ip_address}}
"dst_ip": {{ip_address}} (OPTIONAL)
```
### 2.1.2 VNET/Interface Table
```
VNET|{{vnet_name}}
"vxlan_tunnel": {{tunnel_name}}
"vni": {{vni}}
"scope": {{"default"}} (OPTIONAL)
"peer_list": {{vnet_name_list}} (OPTIONAL)
```

## 2.2 APP DB

### VNET

The following are the changes for Vnet Route table

Existing:

```
VNET_ROUTE_TUNNEL_TABLE:{{vnet_name}}:{{prefix}}
"endpoint": {{ip_address}}
"mac_address":{{mac_address}} (OPTIONAL)
"vni": {{vni}}(OPTIONAL)
```

Proposed:
```
VNET_ROUTE_TUNNEL_TABLE:{{vnet_name}}:{{prefix}}
"endpoint": {{ip_address1},{ip_address2},...}
"endpoint_monitor": {{ip_address1},{ip_address2},...} (OPTIONAL)
prsunny marked this conversation as resolved.
Show resolved Hide resolved
"mac_address":{{mac_address1},{mac_address2},...} (OPTIONAL)
"vni": {{vni1},{vni2},...} (OPTIONAL)
"weight": {{w1},{w2},...} (OPTIONAL)
prsunny marked this conversation as resolved.
Show resolved Hide resolved
“profile”: {{profile_name}} (OPTIONAL)
prsunny marked this conversation as resolved.
Show resolved Hide resolved
```

```
key = VNET_ROUTE_TUNNEL_TABLE:vnet_name:prefix ; Vnet route tunnel table with prefix
; field = value
ENDPOINT = list of ipv4 addresses ; comma separated list of endpoints
ENDPOINT_MONITOR = list of ipv4 addresses ; comma separated list of endpoints
MAC_ADDRESS = 12HEXDIG ; Inner dst mac in encapsulated packet
VNI = DIGITS ; VNI value in encapsulated packet
WEIGHT = DIGITS ; Weights for the nexthops, comma separated (Optional)
PROFILE = STRING ; profile name to be applied for this route, for community
string etc (Optional)
```

### BFD

```
BFD_SESSION:{{ifname}}:{{prefix}}
prsunny marked this conversation as resolved.
Show resolved Hide resolved
prsunny marked this conversation as resolved.
Show resolved Hide resolved
"tx_interval": {{interval}} (OPTIONAL)
prsunny marked this conversation as resolved.
Show resolved Hide resolved
"rx_interval": {{interval}} (OPTIONAL)
"multiplier": {{detection multiplier}} (OPTIONAL)
"shutdown": {{false}}
"multihop": {{false}}
"local_addr": {{ipv4/v6}} (OPTIONAL)
"type": {{string}} (active/passive..)
; Defines APP DB schema to initiate BFD session.
```

## 2.3 Module Interaction

Overlay routes can be programmed via RestAPI or gNMI/gRPC interface which is not described in this document. A highlevel module interaction is shown below
prsunny marked this conversation as resolved.
Show resolved Hide resolved

![](https://github.com/Azure/SONiC/blob/master/images/vxlan_hld/OverlayEcmp_ModuleInteraction.png)

## 2.3 Orchestration Agent
Following orchagents shall be modified.

### VnetOrch

#### Requirements

- Vnetorch to add support to handle multiple endpoints for APP_VNET_RT_TUNNEL_TABLE_NAME based route task.
- Reuse Nexthop tunnel based on the endpoint configuration.
- If there is already the same endpoint exists, use that as member for Nexthop group.
- Similar to above, reuse nexthop group, if multiple routes are programmed with the same set of nexthops.
- Provide support for endpoint modification for a route prefix. Require SAI support for SET operation of routes.
- Provide support for endpoint deletion for a route prefix. Orchagent shall check the existing entries and delete any tunnel/nexthop based on the new route update
- Ensure backward compatibility with single endpoint routes
- Use SAI_NEXT_HOP_GROUP_MEMBER_ATTR_WEIGHT for specifying weights to nexthop member
- Desirable to have per tunnel stats via sai_tunnel_stat_t

#### Detailed flow

VnetOrch is one of the critical module for supporting overlay ecmp. VnetOrch subscribes to VNET and ROUTE updates from APP_DB.

When a new route update is processed by the add operation,

1. VnetOrch checks the nexthop group and if it exists, reuse the group
2. For a new nexthop group member, add the ECMP member and identify the corresponding monitoring IP address. Create a mapping between the monitoring IP and nexthop tunnel endpoint.
prsunny marked this conversation as resolved.
Show resolved Hide resolved
3. Initiate a BFD session for the monitoring IP if it does not exist
4. Based on the BFD implementation (BfdOrch vs Control plane BFD), subscribe to BFD state change, either directly as subject observer (similar to port oper state notifications in orchagent) or via STATEDB update.
prsunny marked this conversation as resolved.
Show resolved Hide resolved
5. Based on the VNET global configuration to advertise prefixes, indicate to STATEDB if the prefix must be advertised by BGP/FRR only if there is atleast one active nexthop. Remove this entry if there are no active nexthops indicated by BFD session down so that the network pfx is no longer advertised.

#### Monitoring Endpoint Mapping

VNET_ROUTE_TUNNEL_TABLE can provide monitoring endpoint IPs which can be different from the tunnel termination endpoints. VnetOrch creates a mapping for such endpoints and based on the monitoring endpoint (MonEP1) health, proceed with adding/removing nexthop tunnel endpoint (EP1) from the ECMP group for the respective prefix. It is assumed that for one tunnel termination endpoint (EP1), there shall be only one corresponding monitoring endpoint (MonEP1).

#### Pros of SWSS to handle route update based on tunnel nexthop health:

- No significant changes, if BFD session management is HW offload via SAI notifications or Control Plane assisted.
- Similar to NHFLAGS handling for existing route ECMP group
- Better performance in re-programming routes in ASIC instead of separate process to monitor and modify each route prefix by updating DB entries

### BfdOrch
Sonic may offload the BFD session handling to hardware that has BFD capabilities. A new module, BfdOrch shall be introduced to handle BFD session to monitoring endpoints and check the health of remote endpoints. BfdOrch shall offload the session initiation/sustenance to hardware via SAI APIs and gets the notifications of session state from SAI. The session state shall be updated in STATE_DB and to any other observer orchestration agents.
prsunny marked this conversation as resolved.
Show resolved Hide resolved
Copy link
Contributor

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

The path from SYNCD to ORCH is quite slow, in such cases the BFD state notification from SYNCD to BFDOrch may add a delta to the desired BFD timeout. The actual BFD timeout achieved may be significantly higher than desired timeout.


![](https://github.com/Azure/SONiC/blob/master/images/vxlan_hld/OverlayEcmp_BFD.png)

For offloading, the following shall be the SAI attributes programmed by BfdOrch.

| Attribute Type | Value |
|--------------------------|--------------------------------|
| SAI_BFD_SESSION_ATTR_TYPE | SAI_BFD_SESSION_TYPE_ASYNC_ACTIVE |
| SAI_BFD_SESSION_ATTR_OFFLOAD_TYPE | SAI_BFD_SESSION_OFFLOAD_TYPE_FULL |
| SAI_BFD_SESSION_ATTR_BFD_ENCAPSULATION_TYPE | SAI_BFD_ENCAPSULATION_TYPE_NONE |
| SAI_BFD_SESSION_ATTR_SRC_IP_ADDRESS | Loopback0 IPv4 or v6 address |
| SAI_BFD_SESSION_ATTR_DST_IP_ADDRESS | Remote IPv4 or v6 address |
| SAI_BFD_SESSION_ATTR_MULTIHOP | True |

Sai shall notify via notification channel on the session state as one of sai_bfd_session_state_t. BfdOrch can listen on these notifications and update the StateDB for the session state.

The flow of BfdOrch is presented in the following figure. BfdOrch subscribes to the BFD_SESSION_TABLE of APPL_DB and send the corresponding request to program the BFD sessions to syncd accordingly. The BfdOrch also creates the STATE_DB entry of the BFD session which includes the BFD parameters and an initial state. Upon receiving bfd session state change notifications from syncd, BfdOrch update the STATE_DB field to update the BFD session state.
prsunny marked this conversation as resolved.
Show resolved Hide resolved

![](https://github.com/Azure/SONiC/blob/master/images/vxlan_hld/OverlayEcmp_BFD_Notification.png)

## 2.5 CLI

The following commands shall be modified/added :

```
- show vnet routes all
- show vnet routes tunnel
- show bfd session <session name>
```