Notifications
You must be signed in to change notification settings - Fork 1.4k
Commit
This commit does not belong to any branch on this repository, and may belong to a fork outside of the repository.
[device]: Accton 5712 Modify sfp to support oom and sfp access by cpl…
…d. Add psuutil (#1542)
- Loading branch information
1 parent
5e2773d
commit ad0ad91
Showing
2 changed files
with
149 additions
and
82 deletions.
There are no files selected for viewing
61 changes: 61 additions & 0 deletions
61
device/accton/x86_64-accton_as5712_54x-r0/plugins/psuutil.py
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,61 @@ | ||
#!/usr/bin/env python | ||
|
||
############################################################################# | ||
# Accton | ||
# | ||
# Module contains an implementation of SONiC PSU Base API and | ||
# provides the PSUs status which are available in the platform | ||
# | ||
############################################################################# | ||
|
||
import os.path | ||
|
||
try: | ||
from sonic_psu.psu_base import PsuBase | ||
except ImportError as e: | ||
raise ImportError (str(e) + "- required module not found") | ||
|
||
class PsuUtil(PsuBase): | ||
"""Platform-specific PSUutil class""" | ||
|
||
def __init__(self): | ||
PsuBase.__init__(self) | ||
|
||
self.psu_path = "/sys/bus/i2c/devices/" | ||
self.psu_presence = "/psu_present" | ||
self.psu_oper_status = "/psu_power_good" | ||
self.psu_mapping = { | ||
1: "57-0038", | ||
2: "58-003b", | ||
} | ||
|
||
def get_num_psus(self): | ||
return len(self.psu_mapping) | ||
|
||
def get_psu_status(self, index): | ||
if index is None: | ||
return False | ||
|
||
status = 0 | ||
node = self.psu_path + self.psu_mapping[index]+self.psu_oper_status | ||
try: | ||
with open(node, 'r') as power_status: | ||
status = int(power_status.read()) | ||
except IOError: | ||
return False | ||
|
||
return status == 1 | ||
|
||
def get_psu_presence(self, index): | ||
if index is None: | ||
return False | ||
|
||
status = 0 | ||
node = self.psu_path + self.psu_mapping[index] + self.psu_presence | ||
try: | ||
with open(node, 'r') as presence_status: | ||
status = int(presence_status.read()) | ||
except IOError: | ||
return False | ||
|
||
return status == 1 |
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters