DellEMC S6000 tmp75 temperature update #3870

Merged
merged 1 commit into from
Dec 13, 2019

Conversation

paavaanan
Copy link
Contributor

- What I did

  • Change tmp75 sensors default temperature value from 25/50 to 70/80 degree.

- How I did it

  • Updated sensors.conf for DellEMC S6000.

- How to verify it

- Description for the changelog

- A picture of a cute animal (not mandatory but encouraged)

@paavaanan
Copy link
Contributor Author

This need to be cherry-picked for 201911 branch

@sujinmkang
Copy link
Collaborator

what does 70/80 means? what will be the fan speed for each temperature range?

@paavaanan
Copy link
Contributor Author

  • 80 is max temperature and 70 is max_hyesteris value. Switch temperature is safe between these values. You can read more about these (max, max_hyst) sensor.conf attributes in
    https://linux.die.net/man/5/sensors.conf

what will be the fan speed for each temperature range?

  • fan-speed/temperature corrleation is handled when we add fancontrol support.

@jleveque
Copy link
Contributor

jleveque commented May 8, 2020

Removed "Request for 201911 Branch" label. We should not cherry-pick a PR forward. PR's should be cherry-picked backward to prevent regressions. I expect Dell to open a separate PR against the master branch, and if it cannot be cherry-picked into the 201911 branch, a separate PR should be opened against that branch.