Notifications
You must be signed in to change notification settings - Fork 1.5k
New issue
Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.
By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.
Already on GitHub? Sign in to your account
[Accton] AS4630-54TE support SystemHealthMonitor #8183
Merged
lguohan
merged 1 commit into
sonic-net:master
from
seanwu-ec:as4630_54te_support_system_health
Jul 24, 2021
Merged
[Accton] AS4630-54TE support SystemHealthMonitor #8183
lguohan
merged 1 commit into
sonic-net:master
from
seanwu-ec:as4630_54te_support_system_health
Jul 24, 2021
Conversation
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
1. Implement FanDrawer-Fan hierarchy. 2. Enable thermalctld, disable pcied. 3. Implement SystemLED in Chassis. 4. Correct Fan direction 5. Implement require Fan APIs for SystemHealthMonitoring. 6. Handle non-ascii character while reading PSU model/serial num. Signed-off-by: Sean Wu <sean_wu@edge-core.com>
lguohan
approved these changes
Jul 24, 2021
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
5 tasks
carl-nokia
pushed a commit
to carl-nokia/sonic-buildimage
that referenced
this pull request
Aug 7, 2021
1. Implement FanDrawer-Fan hierarchy. 2. Enable thermalctld, disable pcied. 3. Implement SystemLED in Chassis. 4. Correct Fan direction 5. Implement require Fan APIs for SystemHealthMonitoring. 6. Handle non-ascii character while reading PSU model/serial num. ``` Check if System-health can pass the check and display the SystemLED correctly. ///////// booting, DIAG_LED = GREEN_BLINKING ///////// root@sonic:/tmp# show system-health detail System is currently booting... root@sonic:/tmp# cat /sys/class/leds/diag/brightness 5 ///////// container_checker fail, DIAG_LED = AMBER ///////// root@sonic:/sys/bus/i2c/devices# show system-health detail System status summary System status LED STATUS_LED_COLOR_AMBER Services: Status: OK Hardware: Status: Not OK Reasons: container_checker is not Status ok System services and devices monitor list Name Status Type -------------------------- -------- ---------- container_checker Not OK Program sonic OK System rsyslog OK Process root-overlay OK Filesystem var-log OK Filesystem routeCheck OK Program diskCheck OK Program container_memory_telemetry OK Program FAN-1F OK Fan FAN-1R OK Fan FAN-2F OK Fan FAN-2R OK Fan FAN-3F OK Fan FAN-3R OK Fan PSU-1 FAN-1 OK Fan PSU-2 FAN-1 OK Fan PSU 1 OK PSU PSU 2 OK PSU System services and devices ignore list Name Status Type --------------- -------- ------ asic Ignored Device psu.temperature Ignored Device ///////// skip container_checker, DIAG_LED = GREEN ///////// root@sonic:/sys/bus/i2c/devices# vi /usr/share/sonic/device/x86_64-accton_as4630_54te-r0/system_health_monitoring_config.json root@sonic:/sys/bus/i2c/devices# root@sonic:/sys/bus/i2c/devices# root@sonic:/sys/bus/i2c/devices# show system-health detail System status summary System status LED STATUS_LED_COLOR_GREEN Services: Status: OK Hardware: Status: OK System services and devices monitor list Name Status Type -------------------------- -------- ---------- sonic OK System rsyslog OK Process root-overlay OK Filesystem var-log OK Filesystem routeCheck OK Program diskCheck OK Program container_memory_telemetry OK Program FAN-1F OK Fan FAN-1R OK Fan FAN-2F OK Fan FAN-2R OK Fan FAN-3F OK Fan FAN-3R OK Fan PSU-1 FAN-1 OK Fan PSU-2 FAN-1 OK Fan PSU 1 OK PSU PSU 2 OK PSU System services and devices ignore list Name Status Type ----------------- -------- ------- container_checker Ignored Service psu.temperature Ignored Device asic Ignored Device ``` Signed-off-by: Sean Wu <sean_wu@edge-core.com>
Sign up for free
to join this conversation on GitHub.
Already have an account?
Sign in to comment
Add this suggestion to a batch that can be applied as a single commit.
This suggestion is invalid because no changes were made to the code.
Suggestions cannot be applied while the pull request is closed.
Suggestions cannot be applied while viewing a subset of changes.
Only one suggestion per line can be applied in a batch.
Add this suggestion to a batch that can be applied as a single commit.
Applying suggestions on deleted lines is not supported.
You must change the existing code in this line in order to create a valid suggestion.
Outdated suggestions cannot be applied.
This suggestion has been applied or marked resolved.
Suggestions cannot be applied from pending reviews.
Suggestions cannot be applied on multi-line comments.
Suggestions cannot be applied while the pull request is queued to merge.
Suggestion cannot be applied right now. Please check back later.
Why I did it
To support system health monitoring feature.
How I did it
Mainly provided a config file, system_health_monitoring_config.json. Then implement the SystemLED part that'd be manipulated by HealthChecker. Others are just to correct the provided information which will be utilized by HardwareChecker.
How to verify it
Check if System-health can pass the check and display the SystemLED correctly.
Which release branch to backport (provide reason below if selected)
Description for the changelog
[Accton] AS4630-54TE support SystemHealthMonitor