Fix for ADC timing for NUCLEO-WL55JC (STM32WLxx) #1766
Merged
Add this suggestion to a batch that can be applied as a single commit.
This suggestion is invalid because no changes were made to the code.
Suggestions cannot be applied while the pull request is closed.
Suggestions cannot be applied while viewing a subset of changes.
Only one suggestion per line can be applied in a batch.
Add this suggestion to a batch that can be applied as a single commit.
Applying suggestions on deleted lines is not supported.
You must change the existing code in this line in order to create a valid suggestion.
Outdated suggestions cannot be applied.
This suggestion has been applied or marked resolved.
Suggestions cannot be applied from pending reviews.
Suggestions cannot be applied on multi-line comments.
Suggestions cannot be applied while the pull request is queued to merge.
Suggestion cannot be applied right now. Please check back later.
This PR fixes/implements the following bugs/features
Motivation
When using the STM32Examples (internal channels) sketch to read the internal ADC values from the NUCLEO-WL55JC (STM32WLxx) the following is observed:
VRef(mv)= 3223 Temp(°C)= -92 Vbat(mv)= 598 A0(mv)= 0
VRef(mv)= 3274 Temp(°C)= -88 Vbat(mv)= 606 A0(mv)= 0
VRef(mv)= 3223 Temp(°C)= -91 Vbat(mv)= 597 A0(mv)= 0
Note that VRef is a little on the low side for USB power and that Temp provides an implausible and erroneous negative number. Vbat is also somewhat questionable.
With the small fix applied the following is observed:
VRef(mv)= 3308 Temp(°C)= 28 Vbat(mv)= 1109 A0(mv)= 0
VRef(mv)= 3310 Temp(°C)= 28 Vbat(mv)= 1110 A0(mv)= 0
VRef(mv)= 3313 Temp(°C)= 29 Vbat(mv)= 1110 A0(mv)= 0
Note that VRef reads more or less correct and that Temp presents a value more aligned with ambient room temperature. Vbat also appears more realistic.
Validation