# Debugging the EC firmware

Terms used:
- *target*: The laptop system that has the EC to be tested
- *host*: The system that will have all devices connected to it and
will receive the EC logs

## Parallel port
## Debugging with target device
1. Install dependencies
```bash
./scripts/deps.sh
```
1. Start the console
```bash
make BOARD=system76/<model> console_internal
```
1. If you're not seeing seeing expected output, check the [log level cflag](https://github.com/system76/ec/blob/master/src/board/system76/common/common.mk#L31-L39). This is an EC compile time configuration and changing will require a build and flash of the EC. You can override this in the untracked `./config.mk` file for example.
## Debugging with external device
### Parallel port
This method replaces the keyboard with a device used for debug logging.
An alternate method of interacting with the target is needed; e.g., an
Expand All @@ -20,7 +32,7 @@ Requirements:
For details on configuring the Mega 2560 and breakout board, see
[mega2560](./mega2560.md).
### Setup
#### Setup
1. Enable parallel port debugging in the EC firmware
- Uncomment `PARALLEL_DEBUG` in `src/board/system76/common/common.mk`
Expand All @@ -46,12 +58,12 @@ To return the Mega 2560 to host mode, reset the device.
If logs are corrupted, try power cycling the Mega or reseating the cable.
## I2C connection
### I2C connection
**Failure to follow steps in order, or performing steps on an
unsupported board, may result in damaged board components.**
### Wiring the target
#### Wiring the target
The I2C connection is made through the battery pins. Find the pins marked
`SMC_BAT` (clock) and `SMD_BAT` (data) in the service manual.
Expand Down Expand Up @@ -86,7 +98,7 @@ oryp7 | 6 | 5
9. Reconnect battery
10. Replace bottom panel
### Setup
#### Setup
Requirements:
- Target wired for EC debugging
Expand Down