Skip to content

Temperature and Humidity d-bus services for Victron GX

License

Notifications You must be signed in to change notification settings

trygvelu/Victron-Service

 
 

Folders and files

NameName
Last commit message
Last commit date

Latest commit

 

History

25 Commits
 
 
 
 
 
 
 
 

Repository files navigation

Victron-Service

Temperature and Humidity d-bus services for Victron GX
Oh! and also now reading the Raspberry Pi CPU temperature which is why I was asked to post this ! This has been updated for Venus 2.8x and Python 3.

Now with added 1 wire support contributed by Albertbm however read the community Notes here regarding setting up 1-wire https://community.victronenergy.com/questions/58792/raspberry-pi-3b-heat-temperature.html (Look for post from olafd Feb 11 2022)

This is a service to publish temperature type data onto the DBus of VenusOs running on a Victron GX device.
Note: Currently this will not display the CPU temperature on Venus GX, only on RPi.

I develop on a Raspberry Pi 3B+, this service was last tested on VenusOS 2.87 in July 2022. I use these service on my Narrowboat Lady's Smock, I am based in the UK.

If all goes well with the install when youstart up your GX device the service will start. The data is published with a type of "Temperature" and will be available:

  1. On the VenusOS DBus API
  2. On the GX console
  3. On the Victron VRM - if you have this configured for you installation

Note, only services of path type "Temperature" will be displayed on the console and VRM If you modify the service to pubish data as a path that is of a different type it will only be available via the DBus and will not appear on the console or VRM.

INSTRUCTIONS

  1. Download the GitHub repo, probably by hitting the green (V Code) button on GITHub

  2. Copy the dbus-i2c directory onto the VenusOS filessystem as /opt/victronenergy/dbus-i2c
    cp -r /dbus-i2c /opt/victronenergy/dbus-i2c

  3. ## create a symlink from /service/dbus-i2c to /opt/victronenergy/dbus-i2c/service
    ## ln -s /opt/victronenergy/dbus-i2c/service /service/dbus-i2c For Venus OS 2.8 (using Python 3), this now needs to be.

mkdir /opt/victronenergy/service/dbus-i2c
cp -r /opt/victronenergy/dbus-i2c/service/* /opt/victronenergy/service/dbus-i2c/

  1. Set execute on the following files (Sadly storing things on github does not preserve execute bits)
    dbus-i2c/i2c.py
    dbus-i2c/start-i2c.sh
    dbus-i2c/check-i2c.sh - this is just a simple file you can use to check if the service is running
    dbus-i2c/service/run
    /service/dbus-i2c

    The command is
    chmod a+x

    So do this for each of the files listed above.

There is a good chance the service will start, if not reboot your VenusOS device
You can check in the file /var/log/dbus-i2c to see what is happening as the service starts up

  1. Go through the file dbus-12c.py and comment out (or uncomment) the setting and creation of each service.
    (OK this could now be a single config section in a future release of the services to run as we have so many.)

For now look here and only enable the services you want.

# So the only service left running is the Raspberry pi CPU temperature.
#
# update_i2c()
# update_adc()
update_rpi()
# update_W1()
return True

ALSO below this line:
# I have commented out the bits that will make new services for i2C and ADC services here
# If you want to re-enable these you need to uncomment the right lines

Look for and comment out the 1-wire (unless you have one)
# dbusservice['W1-temp'] = new_service(base, 'temperature', 'Wire', '1Wire', 0, 28, 5)
and here
# dbusservice['W1-temp'] ['/ProductName'] = '1Wire Sensor'

  1. Currently this will not survive an OS upgrade and will need to be re-installed.
    There are frameworks from other contributors that csn be used to make sure this
    PAckage will remain (or be re-installed) after an upgrade.

NOTES
Why is it call dbus-i2c ? = Well it started as a service to add i2c devices
- you will see I have left the code in just commented it out.

What's the adc stuff? = Victron GX devices only use 5 of the 8 analogue interfaces available
- again this is commented out, if you add an 8 channel adc device to a Raspberry pi you can use the extra 3 channels as additional temperature inputs (the VenusOS code will read it's usual 5 inputs)
In fact there is no conflict as the Venus OS and the service would both quite happily read the same inputs - but you would end up with the same inputs twice in the User Interface.

I added some code recently to enable all the setting of names and temperature offsets as this is supported in VenusOS 2.60.

There is some other useful stuff (Which answers other questions I have seen on the Victron comunity)
Such as how to have one service publish multiple types of data to the DBus from one file.

Hope this all works for you

About

Temperature and Humidity d-bus services for Victron GX

Resources

License

Stars

Watchers

Forks

Releases

No releases published

Packages

No packages published

Languages

  • Python 97.3%
  • Shell 2.7%