inepro: add driver for the PRO380 meter family
- Loading branch information
Holger Steinhaus
committed
Jul 26, 2024
1 parent
17cc89c
commit 2ebf7d5
Showing
2 changed files
with
90 additions
and
0 deletions.
There are no files selected for viewing
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
|
@@ -31,6 +31,7 @@ | |
import cre | ||
import dse | ||
import ev_charger | ||
import inepro | ||
import smappee | ||
import victron_em | ||
|
||
|
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,89 @@ | ||
# SPDX-FileCopyrightText: 2023 Holger Steinhaus | ||
# | ||
# SPDX-License-Identifier: MIT | ||
|
||
import device | ||
import logging | ||
import probe | ||
from register import * | ||
|
||
|
||
log = logging.getLogger() | ||
|
||
|
||
class PRO380_Meter(device.EnergyMeter): | ||
""" | ||
Generic driver for the PRO380 meter series. There are a lot of brandings and variants available, | ||
which are probably working on a similar register map. | ||
All register information based on https://ineprometering.com/wp-content/uploads/2019/04/PRO380-user-manual-V2.18v6.pdf | ||
Attention: The Inepro meter has a two-pole RS485 terminal (D+, D-) without any ground pin. | ||
It therefore does not work with the genuine Victron RS485 cable and requires an INSULATED RS485 adapter! | ||
Using an non-insulated cable will result in strange communication errors like missing bytes and injected zero bytes. | ||
""" | ||
|
||
productid = 0xb077 | ||
productname = 'PRO380-Mod' | ||
|
||
def __init__(self, *args): | ||
super(PRO380_Meter, self).__init__(*args) | ||
|
||
self.info_regs = [ | ||
Reg_u32b(0x4000, '/Serial'), | ||
Reg_u32b(0x4007, '/FirmwareVersion'), | ||
Reg_u32b(0x4009, '/HardwareVersion'), | ||
] | ||
|
||
def phase_regs(self, n): | ||
s = 2 * (n - 1) | ||
return [ | ||
Reg_f32b(0x5002 + s, '/Ac/L%d/Voltage' % n, 1, '%.1f V'), | ||
Reg_f32b(0x500c + s, '/Ac/L%d/Current' % n, 1, '%.1f A'), | ||
Reg_f32b(0x5014 + s, '/Ac/L%d/Power' % n, scale=0.001, text='%.1f W'), | ||
Reg_f32b(0x6012 + s, '/Ac/L%d/Energy/Forward' % n, 1.,'%.1f kWh'), | ||
Reg_f32b(0x601c + s, '/Ac/L%d/Energy/Reverse' % n, 1.,'%.1f kWh'), | ||
] | ||
|
||
def device_init(self): | ||
log.debug("init") | ||
# make sure application is set to H | ||
appreg = Reg_u16(0xa000) | ||
self.read_info() | ||
|
||
phases = 3 | ||
|
||
regs = [ | ||
Reg_f32b(0x5008, '/Ac/Frequency', 1., '%.1f Hz'), | ||
Reg_f32b(0x5012, '/Ac/Power', 0.001, '%.1f W'), | ||
Reg_f32b(0x502a, '/Ac/PowerFactor', 1, '%.1f'), | ||
Reg_f32b(0x600c, '/Ac/Energy/Forward', 1., '%.1f kWh'), | ||
Reg_f32b(0x6018, '/Ac/Energy/Reverse', 1., '%.1f kWh'), | ||
] | ||
|
||
for n in range(1, phases + 1): | ||
regs += self.phase_regs(n) | ||
|
||
self.data_regs = regs | ||
|
||
def dbus_write_register(self, reg, path, val): | ||
super(PRO380_Meter, self).dbus_write_register(reg, path, val) | ||
self.sched_reinit() | ||
|
||
def get_ident(self): | ||
return 'cg_%s' % self.info['/Serial'] | ||
|
||
|
||
models = { | ||
0x2007: { | ||
'model': 'SolarLog PRO380-Mod', | ||
'handler': PRO380_Meter, | ||
}, | ||
} | ||
|
||
|
||
|
||
probe.add_handler(probe.ModelRegister(Reg_u16(0x1010), models, | ||
methods=['rtu'], | ||
rates=[9600], | ||
units=[1])) |