Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

Refactor vertical-temperature-slider Test Plan to V2 Test Format #1159

Open
wants to merge 5 commits into
base: master
Choose a base branch
from
Open
Show file tree
Hide file tree
Changes from all commits
Commits
File filter

Filter by extension

Filter by extension

Conversations
Failed to load comments.
Loading
Jump to
Jump to file
Failed to load files.
Loading
Diff view
Diff view
21 changes: 21 additions & 0 deletions tests/vertical-temperature-slider/data/assertions.csv
Original file line number Diff line number Diff line change
@@ -0,0 +1,21 @@
assertionId,priority,assertionStatement,assertionPhrase,refIds
maximumValue380IsNotConveyed,1,Maximum value '38.0' is not conveyed,maximum value '38.0' is not conveyed,aria-valuemax
minimumValue100IsNotConveyed,1,Minimum value '10.0' is not conveyed,minimum value '10.0' is not conveyed,aria-valuemin
nameTemperature,1,Name 'Temperature' is conveyed,convey name 'Temperature',aria-labelledby
numericValue100IsNotConveyed,1,Numeric value '10.0' is not conveyed,numeric value '10.0' is not conveyed,aria-valuenow
numericValue230IsNotConveyed,1,Numeric value '23.0' is not conveyed,numeric value '23.0' is not conveyed,aria-valuenow
numericValue249IsNotConveyed,1,Numeric value '24.9' is not conveyed,numeric value '24.9' is not conveyed,aria-valuenow
numericValue250IsNotConveyed,1,Numeric value '25.0' is not conveyed,numeric value '25.0' is not conveyed,aria-valuenow
numericValue251IsNotConveyed,1,Numeric value '25.1' is not conveyed,numeric value '25.1' is not conveyed,aria-valuenow
numericValue270IsNotConveyed,1,Numeric value '27.0' is not conveyed,numeric value '27.0' is not conveyed,aria-valuenow
numericValue380IsNotConveyed,1,Numeric value '38.0' is not conveyed,numeric value '38.0' is not conveyed,aria-valuenow
orientationVertical,3,Orientation 'vertical' is conveyed,convey orientation 'vertical',aria-orientation
roleSlider,1,Role 'slider' is conveyed,convey role 'slider',slider
textualValue100DegreesCelsius,1,Textual value '10.0 degrees Celsius' is conveyed,convey textual value '10.0 degrees Celsius',aria-valuetext
textualValue230DegreesCelsius,1,Textual value '23.0 degrees Celsius' is conveyed,convey textual value '23.0 degrees Celsius',aria-valuetext
textualValue249DegreesCelsius,1,Textual value '24.9 degrees Celsius' is conveyed,convey textual value '24.9 degrees Celsius',aria-valuetext
textualValue250DegreesCelsius,1,Textual value '25.0 degrees Celsius' is conveyed,convey textual value '25.0 degrees Celsius',aria-valuetext
textualValue251DegreesCelsius,1,Textual value '25.1 degrees Celsius' is conveyed,convey textual value '25.1 degrees Celsius',aria-valuetext
textualValue270DegreesCelsius,1,Textual value '27.0 degrees Celsius' is conveyed,convey textual value '27.0 degrees Celsius',aria-valuetext
textualValue380DegreesCelsius,1,Textual value '38.0 degrees Celsius' is conveyed,convey textual value '38.0 degrees Celsius',aria-valuetext
interactionModeEnabled,2,Screen reader switched from reading mode to interaction mode|{screenReader} switched from {readingMode} to {interactionMode},switch from reading mode to interaction mode|switch from {readingMode} to {interactionMode},slider
34 changes: 0 additions & 34 deletions tests/vertical-temperature-slider/data/commands.csv

This file was deleted.

19 changes: 19 additions & 0 deletions tests/vertical-temperature-slider/data/jaws-commands.csv
Original file line number Diff line number Diff line change
@@ -0,0 +1,19 @@
testId,command,settings,assertionExceptions,presentationNumber
navForwardsToSlider,down down down,virtualCursor,,1.0
navForwardsToSlider,tab,virtualCursor,2:interactionModeEnabled,1.1
navForwardsToSlider,tab,pcCursor,,3.0
navBackToSlider,up up,virtualCursor,,2.0
navBackToSlider,shift+tab,virtualCursor,2:interactionModeEnabled,2.1
navBackToSlider,shift+tab,pcCursor,,4.0
reqInfoAboutSlider,ins+tab,virtualCursor,,7.0
reqInfoAboutSlider,ins+up,virtualCursor,,7.1
reqInfoAboutSlider,ins+tab,pcCursor,,8.0
reqInfoAboutSlider,ins+up,pcCursor,,8.1
incrementSliderByOneStep,right,pcCursor,,10.0
incrementSliderByOneStep,up,pcCursor,,10.1
decrementSliderByOneStep,left,pcCursor,,12.0
decrementSliderByOneStep,down,pcCursor,,12.1
incrementSliderByTwentySteps,pageUp,pcCursor,,14.0
decrementSliderByTwentySteps,pageDown,pcCursor,,16.0
decrementSliderToMinimumValue,home,pcCursor,,18.0
incrementSliderToMaximumValue,end,pcCursor,,20.0
19 changes: 19 additions & 0 deletions tests/vertical-temperature-slider/data/nvda-commands.csv
Original file line number Diff line number Diff line change
@@ -0,0 +1,19 @@
testId,command,settings,assertionExceptions,presentationNumber
navForwardsToSlider,down down,browseMode,,1.0
navForwardsToSlider,tab,browseMode,2:interactionModeEnabled,1.1
navForwardsToSlider,tab,focusMode,,3.0
navBackToSlider,up up,browseMode,,2.0
navBackToSlider,shift+tab,browseMode,2:interactionModeEnabled,2.1
navBackToSlider,shift+tab,focusMode,,4.0
reqInfoAboutSlider,ins+tab,browseMode,,7.0
reqInfoAboutSlider,ins+up,browseMode,,7.1
reqInfoAboutSlider,ins+tab,focusMode,,8.0
reqInfoAboutSlider,ins+up,focusMode,,8.1
incrementSliderByOneStep,right,focusMode,,10.0
incrementSliderByOneStep,up,focusMode,,10.1
decrementSliderByOneStep,left,focusMode,,12.0
decrementSliderByOneStep,down,focusMode,,12.1
incrementSliderByTwentySteps,pageUp,focusMode,,14.0
decrementSliderByTwentySteps,pageDown,focusMode,,16.0
decrementSliderToMinimumValue,home,focusMode,,18.0
incrementSliderToMaximumValue,end,focusMode,,20.0
32 changes: 16 additions & 16 deletions tests/vertical-temperature-slider/data/references.csv
Original file line number Diff line number Diff line change
@@ -1,16 +1,16 @@
refId,value
author,Isabel Del Castillo
title,Vertical Temperature Slider
authorEmail,isa.delcastillo5@gmail.com
reference,reference/2021-9-21_142211/slider-temperature.html
designPattern,https://w3c.github.io/aria-practices/#slider
example,https://w3c.github.io/aria-practices/examples/slider/slider-temperature.html
slider,https://w3c.github.io/aria/#slider
none,https://w3c.github.io/aria/#none
aria-labelledby,https://w3c.github.io/aria/#aria-labelledby
aria-orientation,https://w3c.github.io/aria/#aria-orientation
aria-valuenow,https://w3c.github.io/aria/#aria-valuenow
aria-valuemin,https://w3c.github.io/aria/#aria-valuemin
aria-valuemax,https://w3c.github.io/aria/#aria-valuemax
aria-valuetext,https://w3c.github.io/aria/#aria-valuetext
aria-hidden,https://w3c.github.io/aria/#aria-hidden
refId,type,value,linkText
author,metadata,Isabel Del Castillo,
title,metadata,Vertical Temperature Slider,
authorEmail,metadata,isa.delcastillo5@gmail.com,
reference,metadata,reference/2021-9-21_142211/slider-temperature.html,Test Case Page for Vertical Temperature Slider
designPattern,metadata,https://www.w3.org/WAI/ARIA/apg/patterns/slider/,APG Pattern: Slider
example,metadata,https://www.w3.org/WAI/ARIA/apg/patterns/slider/examples/slider-temperature/,APG Example: Vertical Temperature Slider
slider,aria,slider,slider
none,aria,none,none
aria-labelledby,aria,aria-labelledby,aria-labelledby
aria-orientation,aria,aria-orientation,aria-orientation
aria-valuenow,aria,aria-valuenow,aria-valuenow
aria-valuemin,aria,aria-valuemin,aria-valuemin
aria-valuemax,aria,aria-valuemax,aria-valuemax
aria-valuetext,aria,aria-valuetext,aria-valuetext
aria-hidden,aria,aria-hidden,aria-hidden
4 changes: 4 additions & 0 deletions tests/vertical-temperature-slider/data/scripts.csv
Original file line number Diff line number Diff line change
@@ -0,0 +1,4 @@
setupScript,setupScriptDescription
setFocusAfterSlider,sets focus on a link after the slider
setFocusBeforeSlider,sets focus on a link before the slider
setFocusOnSlider,sets focus on the slider
Loading