Notifications
You must be signed in to change notification settings - Fork 100
New issue
Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.
By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.
Already on GitHub? Sign in to your account
doc(XCP-ng): Adding multipathing guideline #316
base: master
Are you sure you want to change the base?
Changes from 1 commit
a63616b
3d016e8
543d922
c8dd710
4b95ea6
849f7b5
70ff5cd
246e973
62e9d37
f1f2bd4
File filter
Filter by extension
Conversations
Jump to
Diff view
Diff view
There are no files selected for viewing
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,260 @@ | ||
--- | ||
sidebar_position: 1 | ||
--- | ||
|
||
# Multipathing | ||
|
||
How to properly setup storage multipathing with Xen Orchestra and XCP-ng. | ||
|
||
## iSCSI | ||
|
||
### Requirements | ||
* Two different network cards (It can be the same model) | ||
* Dedicated network interfaces without VLAN tagging on XCP-ng host and storage unit | ||
* Two different switches (not stacked) | ||
* Two VLANs **without L3 routing** | ||
There was a problem hiding this comment. Choose a reason for hiding this commentThe reason will be displayed to describe this comment to others. Learn more. storage vlans can be routed, it works, it just takes a little more setup. Again I think we should remove these out of scope reqs |
||
* Two IPv4 subnets **without L3 routing** | ||
* Multiple targets per LUN on your storage unit | ||
* iSCSI target ports are operating in portal mode | ||
|
||
:::info | ||
It is recommended to configure the network interfaces of XCP-ng host servers, switch interfaces, and storage array interfaces with Jumbo frames (MTU 9000). | ||
There was a problem hiding this comment. Choose a reason for hiding this commentThe reason will be displayed to describe this comment to others. Learn more. All network interfaces, or those dedicated to storage? I often heard @Fohdeesha say that MTU 9000 is usually not required nowadays, and complain about users who automatically put MTU 9000, not always doing it right, and causing all kinds of networking issues (I can remember a recent nightmarish ticket). There was a problem hiding this comment. Choose a reason for hiding this commentThe reason will be displayed to describe this comment to others. Learn more. Please read the entire note. There was a problem hiding this comment. Choose a reason for hiding this commentThe reason will be displayed to describe this comment to others. Learn more. So, I had read the entire note. But it doesn't answer my question. So I'll try to put it in a different way: you wrote There was a problem hiding this comment. Choose a reason for hiding this commentThe reason will be displayed to describe this comment to others. Learn more. I'm only talking about iSCSI interfaces, not the others. This is iSCSI/FC multipathing documentation: all other interfaces are out of scope and will never be mentioned. There was a problem hiding this comment. Choose a reason for hiding this commentThe reason will be displayed to describe this comment to others. Learn more. I really really really advise against broadly recommending jumbo frames - on hardware from the last ten or even 15 years, on 10gbE interfaces there is no performance gain - and it opens up a huge box of potential issues that users are going to get themselves into. Something more specific like "if your storage vendor recommends jumbo frames, then do xxx" would be much safer There was a problem hiding this comment. Choose a reason for hiding this commentThe reason will be displayed to describe this comment to others. Learn more.
I thought we had an agreement about this on thursday, after one full hour trying to make you consider my request, and now we're back again to "my document is good as is it, I know my stuff and I won't change it". That's not how peer reviewing works. We have a lot of experience in anticipating how users may interpret stuff the wrong way, and we've spent a lot more time arguing than it would have taken you to add the one or two words that would specify which NICs this applies to. Your document exists in a broader context, a hypervisor with a complex networking setup, that it's easy to get wrong (ask @Fohdeesha about it). What's obvious to you ("all other interfaces are out of scope and will never be mentioned") is not necessarily obvious to users. When you have the opportunity to make this more obvious, always do. Let's not leave any ambiguity. Jon's comment also raises important questions, and I kind of agree with him, but I won't take a decision about it for now as it probably requires more internal discussion. |
||
|
||
If your switch cannot handle Jumbo frames, you can leave the default values (MTU 1500). But make sure that all elements are set to MTU 1500. | ||
::: | ||
|
||
:::warning | ||
1. Make sure you do not use bond-type network interfaces on the host and on the storage unit for iSCSI interfaces. | ||
2. Make sure you do not configure network routes on iSCSI interfaces. | ||
::: | ||
|
||
### Target architecture | ||
|
||
#### Configuration example | ||
| Path | Vlan | Subnet | Host PIF address | Storage Controller 1 address | Storage Controller 2 address | | ||
| :---: | :---: | :---: | :---: | :---: | :---: | | ||
| 🔵 | 421 | 10.42.1.0/24 | 10.42.1.11 | 10.42.1.101 | 10.42.1.102 | | ||
| 🟢 | 422 | 10.42.2.0/24 | 10.42.2.11 | 10.42.2.101 | 10.42.2.102 | | ||
|
||
#### Target architecture diagram | ||
```mermaid | ||
--- | ||
config: | ||
look: handDrawn | ||
theme: default | ||
--- | ||
flowchart LR | ||
classDef blueNode fill:#A7C8F0,stroke:#2C6693,color:#000000; | ||
classDef greenNode fill:#A8E6A2,stroke:#3E8E41,color:#000000; | ||
classDef grayNode fill:#D6D6D6,stroke:#8C8C8C,color:#000000; | ||
|
||
subgraph server[XCP-ng host] | ||
direction LR | ||
subgraph Card2[Network card 2] | ||
direction RL | ||
card2pif1[pif4] | ||
card2pif2[pif3] | ||
end | ||
subgraph Card1[Network card 1] | ||
direction RL | ||
card1pif1[pif1] | ||
card1pif2[pif2] | ||
end | ||
end | ||
subgraph Switch 2 | ||
vlan422[vlan422]:::greenNode | ||
end | ||
subgraph Switch 1 | ||
vlan421[vlan421]:::blueNode | ||
end | ||
subgraph storage[Storage unit] | ||
direction LR | ||
subgraph ctrl2[Controller 2] | ||
direction RL | ||
ctrl2-port1[port1] | ||
ctrl2-port2[port2] | ||
end | ||
subgraph ctrl1[Controller 1] | ||
direction RL | ||
ctrl1-port1[port1] | ||
ctrl1-port2[port2] | ||
end | ||
lun1@{ shape: lin-cyl, label: "LUN" } | ||
|
||
end | ||
|
||
card1-pif1-ip([10.42.1.11/24]):::blueNode | ||
card1-pif2-ip([other networks]):::grayNode | ||
card2-pif2-ip([10.42.2.11/24]):::greenNode | ||
card2-pif1-ip([other networks]):::grayNode | ||
ctrl1-port1-ip([10.42.1.101/24]):::blueNode | ||
ctrl1-port2-ip([10.42.2.101/24]):::greenNode | ||
ctrl2-port1-ip([10.42.1.102/24]):::blueNode | ||
ctrl2-port2-ip([10.42.2.102/24]):::greenNode | ||
|
||
card1pif1<-->card1-pif1-ip | ||
card1-pif1-ip<-->vlan421 | ||
vlan421<-->ctrl1-port1-ip | ||
ctrl1-port1-ip<-->ctrl1-port1 | ||
vlan421<-->ctrl2-port1-ip | ||
ctrl2-port1-ip<-->ctrl2-port1 | ||
|
||
card2pif2<-->card2-pif2-ip | ||
card2-pif2-ip<-->vlan422 | ||
vlan422<-->ctrl1-port2-ip | ||
ctrl1-port2-ip<-->ctrl1-port2 | ||
vlan422<-->ctrl2-port2-ip | ||
ctrl2-port2-ip<-->ctrl2-port2 | ||
|
||
card1pif2<-->card1-pif2-ip | ||
card2pif1<-->card2-pif1-ip | ||
ctrl1 <----> lun1 | ||
ctrl2 <----> lun1 | ||
|
||
linkStyle 0 stroke:#4A90E2,stroke-width:2px; | ||
linkStyle 1 stroke:#4A90E2,stroke-width:2px; | ||
linkStyle 2 stroke:#4A90E2,stroke-width:2px; | ||
linkStyle 3 stroke:#4A90E2,stroke-width:2px; | ||
linkStyle 4 stroke:#4A90E2,stroke-width:2px; | ||
linkStyle 5 stroke:#4A90E2,stroke-width:2px; | ||
|
||
linkStyle 6 stroke:#5CB85C,stroke-width:2px; | ||
linkStyle 7 stroke:#5CB85C,stroke-width:2px; | ||
linkStyle 8 stroke:#5CB85C,stroke-width:2px; | ||
linkStyle 9 stroke:#5CB85C,stroke-width:2px; | ||
linkStyle 10 stroke:#5CB85C,stroke-width:2px; | ||
linkStyle 11 stroke:#5CB85C,stroke-width:2px; | ||
|
||
linkStyle 12 stroke:#8C8C8C,stroke-width:2px; | ||
linkStyle 13 stroke:#8C8C8C,stroke-width:2px; | ||
``` | ||
|
||
### Operating procedure | ||
stormi marked this conversation as resolved.
Show resolved
Hide resolved
|
||
|
||
#### 1. Prepare XCP-ng hosts | ||
1. On one of the host servers, make sure that the multipath.conf configuration includes your storage equipment. | ||
|
||
This can be found in the file `/etc/multipath.xenserver/multipath.conf` | ||
2. If your equipment is not present, ask the manufacturer for the multipath configuration for GNU/Linux | ||
|
||
Add it to the file ```/etc/multipath/conf.d/custom.conf``` | ||
ylebris marked this conversation as resolved.
Show resolved
Hide resolved
|
||
|
||
:::info | ||
In this case, the configuration will be kept after updates. | ||
::: | ||
|
||
3. If necessary, migrate the VMs active on the XCP-ng host in question to another one | ||
4. Reboot the current XCP-ng host on the affected pool | ||
5. Do the same for all servers in the pool | ||
|
||
#### 2. Prepare the pool | ||
Make sure that multipathing is enabled on the pool. To do this, go to the advanced configuration of the pool | ||
|
||
If this is not the case: | ||
1. Make sure there are **no VMs running** on an iSCSI and/or HBA SR in the pool | ||
2. Activate "Enable multipathing for all hosts" | ||
|
||
#### 3. Configure the SR | ||
Proceed with the iSCSI SR configuration as indicated in the [storage documentation](../../storage/#iscsi). | ||
|
||
## Fiber Channel (HBA) | ||
ylebris marked this conversation as resolved.
Show resolved
Hide resolved
|
||
### Requirements | ||
* Check that the Fiber Channel cards model(s) is supported via the HCL | ||
* Two different Fiber Channel cards (It can be the same model) | ||
ylebris marked this conversation as resolved.
Show resolved
Hide resolved
|
||
* Two different SAN switches | ||
* Multiple targets per LUN on your storage unit | ||
* Zoning performed | ||
|
||
:::warning | ||
Make sure not to mix Fiber Channel speeds. | ||
::: | ||
|
||
### Target architecture | ||
#### Target architecture diagram | ||
```mermaid | ||
--- | ||
config: | ||
look: handDrawn | ||
theme: default | ||
--- | ||
flowchart LR | ||
classDef blueNode fill:#A7C8F0,stroke:#2C6693,color:#000000; | ||
classDef greenNode fill:#A8E6A2,stroke:#3E8E41,color:#000000; | ||
classDef grayNode fill:#D6D6D6,stroke:#8C8C8C,color:#000000; | ||
|
||
subgraph server[XCP-ng host] | ||
direction LR | ||
subgraph Card2[Fiber Channel card 2] | ||
direction RL | ||
card2port1[port1] | ||
end | ||
subgraph Card1[Fiber Channel card 1] | ||
direction RL | ||
card1port1[port1] | ||
end | ||
end | ||
|
||
subgraph storage[Storage unit] | ||
direction LR | ||
subgraph ctrl2[Controller 2] | ||
direction RL | ||
ctrl2-port1[port1] | ||
ctrl2-port2[port2] | ||
end | ||
subgraph ctrl1[Controller 1] | ||
direction RL | ||
ctrl1-port1[port1] | ||
ctrl1-port2[port2] | ||
end | ||
lun1@{ shape: lin-cyl, label: "LUN" } | ||
|
||
end | ||
|
||
vlan421[SAN Switch 1]:::blueNode | ||
vlan422[SAN Switch 2]:::greenNode | ||
|
||
card1port1<---->vlan421 | ||
vlan421<---->ctrl1-port1 | ||
vlan421<---->ctrl2-port1 | ||
|
||
card2port1<---->vlan422 | ||
vlan422<---->ctrl1-port2 | ||
vlan422<---->ctrl2-port2 | ||
|
||
ctrl1 <----> lun1 | ||
ctrl2 <----> lun1 | ||
|
||
linkStyle 0 stroke:#4A90E2,stroke-width:2px; | ||
linkStyle 1 stroke:#4A90E2,stroke-width:2px; | ||
linkStyle 2 stroke:#4A90E2,stroke-width:2px; | ||
linkStyle 3 stroke:#5CB85C,stroke-width:2px; | ||
linkStyle 4 stroke:#5CB85C,stroke-width:2px; | ||
linkStyle 5 stroke:#5CB85C,stroke-width:2px; | ||
``` | ||
### Operating procedure | ||
|
||
#### 1. Prepare XCP-ng hosts | ||
1. On one of the host servers, make sure that the multipath.conf configuration includes your storage equipment. | ||
|
||
This can be found in the file `/etc/multipath.xenserver/multipath.conf` | ||
2. If your equipment is not present, ask the manufacturer for the multipath configuration for GNU/Linux | ||
|
||
Add it to the file ```/etc/multipath/conf.d/custom.conf``` | ||
ylebris marked this conversation as resolved.
Show resolved
Hide resolved
|
||
|
||
:::info | ||
In this case, the configuration will be kept after updates. | ||
::: | ||
|
||
3. If necessary, migrate the VMs active on the XCP-ng host in question to another one | ||
4. Reboot the current XCP-ng host on the affected pool | ||
5. Do the same for all servers in the pool | ||
|
||
#### 2. Prepare the pool | ||
Make sure that multipathing is enabled on the pool. To do this, go to the advanced configuration of the pool | ||
|
||
If this is not the case: | ||
1. Make sure there are **no VMs running** on an iSCSI and/or HBA SR in the pool | ||
2. Activate "Enable multipathing for all hosts" | ||
|
||
#### 3. Configure the SR | ||
Proceed with the HBA SR configuration as indicated in the [storage documentation](../../storage/#hba). |
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
this is also not necessary, we have a ton of users and customers running iSCSI storage over vlans, there's nothing wrong with it at all