EEG - confusion between channels.tsv and electrodes.tsv #667
Comments
electrodes.tsv could have more electrodes than present in channels.tsv for example in the case where an EOG channel (1 channel) is recorded from 2 electrodes with bipolar referencing scheme. |
actually, could you please cite where you get that idea from? I read the parts of the spec again, and I cannot find that rule. It also wouldn't make sense in my opinion, apart from the example about bipolar electrodes I listed above. --> Just thinking about a "normal" EEG recording with a reference and a ground electrode --> neither of these two electrodes are "channels" ... but they should be written down in electrodes.tsv. Unless more information comes up, I would say that we should rather enhance the specification with one or two examles of why the We hint at that in the intro:
|
…nels+electrodes do not have to match (#734) * clarify that label of _space-<label> must be from appendix VIII related to https://github.com/bids-standard/bids-validator/issues/743 * clarify that channels and electrodes do not have to match closes #667 * catch typo again * link channels+electrodes examples * clarify _where_ restricted keywords for space entity come from * fix typo L -> l (capitalization) Co-authored-by: Chris Markiewicz <effigies@gmail.com> * extend yml lint limit to 120 chard * use existing .yamllint.yml file Co-authored-by: Chris Markiewicz <effigies@gmail.com>
we could suggest to use the the same names for electrodes and channels |
On the topic of adding some examples where it is more difficult to match the positions (in addition to bipolar recordings): Example 1: a dataset in which an ECG channel is recorded simultaneously with SEEG. The ECG electrode is not present or is n/a in _electrodes.tsv Example 2: EEG and SEEG are simultaneously recorded and the EEG positions may not be present or are in a different space than the SEEG positions. However, if a name in _channels.tsv is not present in _electrodes.tsv that maybe should raise a flag? |
This dataset for example (https://openneuro.org/datasets/ds002791/versions/1.0.0) has different channel names in its channels.tsv and electrodes.tsv files.
sub-01/ses-naming/eeg/sub-01_ses-naming_run-1_electrodes.tsv
F10h 6.962 5.382 -2.191
F8 6.484 6.404 -0.14
AFF8h 5.699 7.208 1.791
sub-01/ses-naming/eeg/sub-01_ses-naming_run-1_channels.tsv
E1 eeg microV 1000 n/a n/a n/a n/a n/a n/a n/a
E2 eeg microV 1000 n/a n/a n/a n/a n/a n/a n/a
E3 eeg microV 1000 n/a n/a n/a n/a n/a n/a n/a
...
The specification suggests that the name should be the same. It also does not enforce that electrodes.tsv should have the same number of rows as channels.tsv.
https://bids-specification.readthedocs.io/en/latest/04-modality-specific-files/03-electroencephalography.html
Solutions: