- The scan set to be displayed can be selected from CERR's menu bar located at the top .
- Scan display can be turned off by de-selecting View -> Scan
- Scan sets displayed on individual panels can be changed by right-clicking the panel and then selecting the desired scan set.
- Scan transparency can be adjusted by moving the scan/dose slider located on the left side of the Viewer.
- The scan management window (Scan -> Scan Management) can be used to delete scans from planC.
Scans are stored in the planC cell array and can be accessed as follows:
>> scanNum = 1;
>> planC{indexS.scan}(scanNum)
ans =
scanArray: [256x256x68 uint16]
scanType: 'CT'
scanInfo: [1x68 struct]
uniformScanInfo: [1x1 struct]
scanArraySuperior: [256x256x28 uint16]
scanArrayInferior: [256x256x47 uint16]
thumbnails: [1x1 struct]
transM: []
scanUID: 'CT.3172006.10934.02534.079'
Notice that the fieldnames are similar to ones used in RTOG specification. Some of the important fields are:
'.scanArray' - stores the volumetric scan data,
'.transM' - stores the 4x4 rigid-transformation matrix,
'.scanUID' - stores the unique identifier for this scan. Note that this fields gets modified (or should be modified) whenever user changes any data associated with this scan.
'.scanInfo' - is a structure array which stores the information for each slice. For example, the 1st information for 1st slice can be obtained as follows:
>> sliceNum = 1;
>> planC{indexS.scan}(scanNum).scanInfo(sliceNum)
ans =
imageNumber: 1
imageType: 'CT Scan'
caseNumber: 'orart1_hn'
patientName: 'orart1_hn'
scanType: 'TRANSVERSE'
CTOffset: 1024
grid1Units: 0.2000
grid2Units: 0.2000
numberRepresentation: 'TWO'S COMPLEMENT INTEGER'
bytesPerPixel: 2
numberOfDimensions: 2
sizeOfDimension1: 256
sizeOfDimension2: 256
zValue: 0.1000
xOffset: 25.6000
yOffset: 25.6000
CTAir: 0
CTWater: 1024
sliceThickness: 0.3500
siteOfInterest:
unitNumber:
scanDescription:
scannerType: 'Picker International, Inc. PQ2000'
scanFileName:
headInOut: 'IN'
positionInScan: 'NOSE UP'
patientAttitude:
tapeOfOrigin:
studyNumberOfOrigin: 'orart1_hn'
scanID:
scanNumber:
scanDate:
CTScale:
distrustAbove:
imageSource:
bookmarked: 0
transferProtocol:
DICOMHeaders:
The coordinates of the scan grid can be obtained by using the getScanXYZVals
CERR function as follows:
>> [xScanVals, yScanVals, zScanVals] = getScanXYZVals(planC{indexS.scan}(scanNum))
global planC
indexS = planC{end};
scan3M = double(getScanArray(scanNum,planC));
CToffset = planC{indexS.scan}(scanNum).scanInfo(1).CTOffset;
scan3M = scan3M - CTOffset;