Fixes #684.

@ivanstepanovftw
Copy link
Collaborator Author

Original LLaMA's generate defines temperature like so:

        if temperature > 0:
            probs = torch.softmax(logits / temperature, dim=-1)
            next_token = sample(probs, top_p=top_p, top_k=top_k)
        else:
            next_token = torch.argmax(logits, dim=-1)

@prusnak
Copy link
Collaborator

prusnak commented Apr 2, 2023

@abetlen can you please also test this one?

@abetlen
Copy link
Collaborator

abetlen commented Apr 2, 2023

@prusnak tested and can confirm this works as well.

@prusnak prusnak merged commit cd7fa95 into ggml-org:master Apr 3, 2023
Copy link
Contributor

@Fabio3rs Fabio3rs left a comment

Choose a reason for hiding this comment

The reason will be displayed to describe this comment to others. Learn more.

This alternative seems to me to harmonize better with the rest of the code