[openwebnet] add support for Thermoregulation (standalone thermostat and sensors) #10756

Merged
merged 15 commits into from
Jun 5, 2021
Merged
Show file tree
Hide file tree
Changes from all commits
Commits
File filter

Filter by extension

Filter by extension


Conversations
Failed to load comments.
Loading
Jump to
Jump to file
Failed to load files.
Loading
Diff view
Diff view
91 changes: 64 additions & 27 deletions bundles/org.openhab.binding.openwebnet/README.md
Original file line number Diff line number Diff line change
Expand Up @@ -37,20 +37,21 @@ The following Things and OpenWebNet `WHOs` are supported:

### For BUS/SCS

| Category | WHO | Thing Type IDs | Description | Status |
| -------------------- | :----------: | :------------------------------------------: | -------------------------------------------------------------- | ---------------- |
| Gateway Management | `13` | `bus_gateway` | Any IP gateway supporting OpenWebNet protocol should work (e.g. F454 / MyHOMEServer1 / MH202 / F455 / MH200N, ...) | Successfully tested: F454, MyHOMEServer1, MyHOME_Screen10, F455, F452, F453AV, MH201, MH202, MH200N. Some connection stability issues/gateway resets reported with MH202 |
| Lighting | `1` | `bus_on_off_switch`, `bus_dimmer` | BUS switches and dimmers | Successfully tested: F411/2, F411/4, F411U2, F422, F429. Some discovery issues reported with F429 (DALI Dimmers) |
| Automation | `2` | `bus_automation` | BUS roller shutters, with position feedback and auto-calibration | Successfully tested: LN4672M2 |
| Energy Management | `18` | `bus_energy_meter` | Energy Management | Successfully tested: F520, F521 |
| Category | WHO | Thing Type IDs | Description | Status |
| -------------------- | :----------: | :---------------------------------: | ---------------------------------------------------------------- | ---------------- |
| Gateway Management | `13` | `bus_gateway` | Any IP gateway supporting OpenWebNet protocol should work (e.g. F454 / MyHOMEServer1 / MH202 / F455 / MH200N, ...) | Successfully tested: F454, MyHOMEServer1, MyHOME_Screen10, F455, F452, F453AV, MH201, MH202, MH200N. Some connection stability issues/gateway resets reported with MH202 |
| Lighting | `1` | `bus_on_off_switch`, `bus_dimmer` | BUS switches and dimmers | Successfully tested: F411/2, F411/4, F411U2, F422, F429. Some discovery issues reported with F429 (DALI Dimmers) |
| Automation | `2` | `bus_automation` | BUS roller shutters, with position feedback and auto-calibration | Successfully tested: LN4672M2 |
| Temperature Control | `4` | `bus_thermostat`, `bus_temp_sensor` | Zones room thermostats (stand-alone) and external wireless temperature sensors. Please note that Central Unit configurations (4 or 99 zones) are not yet supported. See [Channels - Thermo](#thermo-channels) for more details. | Successfully tested: H/LN4691; external sensors: L/N/NT4577 + 3455 |
| Energy Management | `18` | `bus_energy_meter` | Energy Management | Successfully tested: F520, F521 |

### For ZigBee (Radio)

| Category | WHO | Thing Type IDs | Description | Status |
| -------------------- | :----: | :-------------------------------: | :-------------------------------------------------------------------: | ------------------------------------ |
| Gateway Management | `13` | `zb_gateway` | ZigBee USB Gateway (models: BTI-3578 / LG 088328) | Tested: BTI-3578 and LG 088328 |
| Lighting | `1` | `zb_dimmer`, `zb_on_off_switch`, `zb_on_off_switch2u` | ZigBee dimmers, switches and 2-unit switches | Tested: BTI-4591, BTI-3584, BTI-4585 |
| Automation | `2` | `zb_automation` | ZigBee roller shutters | |
| Gateway Management | `13` | `zb_gateway` | ZigBee USB Gateway (models: BTI-3578 / LG 088328) | Tested: BTI-3578 and LG 088328 |
| Lighting | `1` | `zb_dimmer`, `zb_on_off_switch`, `zb_on_off_switch2u` | ZigBee dimmers, switches and 2-unit switches | Tested: BTI-4591, BTI-3584, BTI-4585 |
| Automation | `2` | `zb_automation` | ZigBee roller shutters | |

## Discovery

Expand Down Expand Up @@ -121,18 +122,36 @@ For any manually added device, you must configure:
- the `where` config parameter (`OpenWebNet Device Address`):
- example for BUS/SCS device with WHERE address Point to Point `A=2 PL=4` --> `where="24"`
- example for BUS/SCS device with WHERE address Point to Point `A=03 PL=11` on local bus --> `where="0311#4#01"`
- example for BUS/SCS thermo Zones: `Zone=1` --> `where="1"`; external sensor `5` --> `where="500"`
- example for ZigBee devices: `where=765432101#9`. The ID of the device (ADDR part) is usually written in hexadecimal on the device itself, for example `ID 0074CBB1`: convert to decimal (`7654321`) and add `01#9` at the end to obtain `where=765432101#9`. For 2-unit switch devices (`zb_on_off_switch2u`), last part should be `00#9`.

## Channels
## Channels

### Lighting, Automation and Power meter channels

| Channel Type ID (channel ID) | Applies to Thing Type IDs | Item Type | Description | Read/Write |
| ---------------------------------------- | ------------------------------------------------------------- | ------------- | ----------------------------------------------------- | :--------: |
| `switch` or `switch_01`/`02` for ZigBee | `bus_on_off_switch`, `zb_on_off_switch`, `zb_on_off_switch2u` | Switch | To switch the device `ON` and `OFF` | R/W |
| `brightness` | `bus_dimmer`, `zb_dimmer` | Dimmer | To adjust the brightness value (Percent, `ON`, `OFF`) | R/W |
| `shutter` | `bus_automation` | Rollershutter | To activate roller shutters (`UP`, `DOWN`, `STOP`, Percent - [see Shutter position](#shutter-position)) | R/W |
| `power` | `bus_energy_meter` | Number:Power | The current active power usage from Energy Meter | R |

### Thermo channels

Currently only stand-alone thermostats are supported (like [LN4691](https://catalogo.bticino.it/BTI-LN4691-IT)) and the specific thing `bus_thermostat` was created to manage them.

| Channel Type ID (channel ID) | Applies to Thing Type IDs | Item Type | Description | Read/Write | Advanced |
| ---------------------------- | ----------------------------------- | ------------------ | ------------------------------------------------- | :--------: | :------: |
| `temperature` | `bus_thermostat`, `bus_temp_sensor` | Number:Temperature | The zone currently sensed temperature | R | N |
| `setpointTemperature` | `bus_thermostat` | Number:Temperature | The zone setpoint temperature | R/W | N |
| `function` | `bus_thermostat` | String | The zone set thermo function: `COOLING`, `HEATING` or `GENERIC` (heating + cooling) | R/W | N |
| `mode` | `bus_thermostat` | String | The zone set mode: `MANUAL`, `PROTECTION`, `OFF` | R/W | N |
| `speedFanCoil` | `bus_thermostat` | String | The zone fancoil speed: `AUTO`, `SPEED_1`, `SPEED_2`, `SPEED_3` | R/W | N |
| `actuator` | `bus_thermostat` | String | The zone actuator(s) status: `OFF`, `ON`, `OPENED`, `CLOSED` , `STOP`, `OFF_FAN_COIL`, `ON_SPEED_1`, `ON_SPEED_2`, `ON_SPEED_3`, `OFF_SPEED_1`, `OFF_SPEED_2`, `OFF_SPEED_3` | R | Y |
| `heatingValve` | `bus_thermostat` | String | The zone heating valve(s) status: `OFF`, `ON`, `OPENED`, `CLOSED` , `STOP`, `OFF_FAN_COIL`, `ON_SPEED_1`, `ON_SPEED_2`, `ON_SPEED_3`, `OFF_SPEED_1`, `OFF_SPEED_2`, `OFF_SPEED_3` | R | Y |
| `conditioningValve` | `bus_thermostat` | String | The zone conditioning valve(s) status: `OFF`, `ON`, `OPENED`, `CLOSED` , `STOP`, `OFF_FAN_COIL`, `ON_SPEED_1`, `ON_SPEED_2`, `ON_SPEED_3`, `OFF_SPEED_1`, `OFF_SPEED_2`, `OFF_SPEED_3` | R | Y |

Devices support some of the following channels:

| Channel Type ID (channel ID) | Item Type | Description | Read/Write |
|------------------------------------------------|---------------|---------------------------------------------------------|:----------:|
| `switch` or `switch_01`/`02` for ZigBee | Switch | To switch the device `ON` and `OFF` | R/W |
| `brightness` | Dimmer | To adjust the brightness value (Percent, `ON`, `OFF`) | R/W |
| `shutter` | Rollershutter | To activate roller shutters (`UP`, `DOWN`, `STOP`, Percent - [see Shutter position](#shutter-position)) | R/W |
| `power` | Number:Power | The current active power usage from Energy Meter | R |
### Notes on channels

#### `shutter` position
Expand All @@ -154,11 +173,13 @@ BUS gateway and things configuration:

```xtend
Bridge openwebnet:bus_gateway:mybridge "MyHOMEServer1" [ host="192.168.1.35", passwd="abcde", port=20000, discoveryByActivation=false ] {
bus_on_off_switch LR_switch "Living Room Light" [ where="51" ]
bus_dimmer LR_dimmer "Living Room Dimmer" [ where="0311#4#01" ]
bus_automation LR_shutter "Living Room Shutter" [ where="93", shutterRun="10050"]
bus_energy_meter CENTRAL_Ta "Energy Meter Ta" [ where="51" ]
bus_energy_meter CENTRAL_Tb "Energy Meter Tb" [ where="52" ]
bus_on_off_switch LR_switch "Living Room Light" [ where="51" ]
bus_dimmer LR_dimmer "Living Room Dimmer" [ where="0311#4#01" ]
bus_automation LR_shutter "Living Room Shutter" [ where="93", shutterRun="10050"]
bus_energy_meter CENTRAL_Ta "Energy Meter Ta" [ where="51" ]
bus_energy_meter CENTRAL_Tb "Energy Meter Tb" [ where="52" ]
bus_thermostat LR_thermostat "Living Room Thermostat" [ where="2"]
bus_temp_sensor EXT_tempsensor "External Temperature" [ where="500"]
}
```

Expand All @@ -178,11 +199,18 @@ Bridge openwebnet:zb_gateway:myZBgateway [ serialPort="COM3" ] {
Example items linked to BUS devices:

```xtend
Switch iLR_switch "Light" <light> (gLivingRoom) [ "Lighting" ] { channel="openwebnet:bus_on_off_switch:mybridge:LR_switch:switch" }
Dimmer iLR_dimmer "Dimmer [%.0f %%]" <DimmableLight> (gLivingRoom) [ "Lighting" ] { channel="openwebnet:bus_dimmer:mybridge:LR_dimmer:brightness" }
Rollershutter iLR_shutter "Shutter [%.0f %%]" <rollershutter> (gShutters, gLivingRoom) [ "Blinds" ] { channel="openwebnet:bus_automation:mybridge:LR_shutter:shutter" }
Number:Power iCENTRAL_Ta "Power [%.0f %unit%]" <energy> { channel="openwebnet:bus_energy_meter:mybridge:CENTRAL_Ta:power" }
Number:Power iCENTRAL_Tb "Power [%.0f %unit%]" <energy> { channel="openwebnet:bus_energy_meter:mybridge:CENTRAL_Tb:power" }
Switch iLR_switch "Light" <light> (gLivingRoom) [ "Lighting" ] { channel="openwebnet:bus_on_off_switch:mybridge:LR_switch:switch" }
Dimmer iLR_dimmer "Dimmer [%.0f %%]" <DimmableLight> (gLivingRoom) [ "Lighting" ] { channel="openwebnet:bus_dimmer:mybridge:LR_dimmer:brightness" }
Rollershutter iLR_shutter "Shutter [%.0f %%]" <rollershutter> (gShutters, gLivingRoom) [ "Blinds" ] { channel="openwebnet:bus_automation:mybridge:LR_shutter:shutter" }
Number:Power iCENTRAL_Ta "Power [%.0f %unit%]" <energy> { channel="openwebnet:bus_energy_meter:mybridge:CENTRAL_Ta:power" }
Number:Power iCENTRAL_Tb "Power [%.0f %unit%]" <energy> { channel="openwebnet:bus_energy_meter:mybridge:CENTRAL_Tb:power" }
Number:Temperature iLR_thermostat_temp "Temperature" (gLivingRoom) { channel="openwebnet:bus_thermostat:mybridge:LR_thermostat:temperature" }
Number:Temperature iLR_thermostat_set "SetPoint Temperature" (gLivingRoom) { channel="openwebnet:bus_thermostat:mybridge:LR_thermostat:setpointTemperature" }
String iLR_thermostat_setFanSpeed "FanSpeed" (gLivingRoom) { channel="openwebnet:bus_thermostat:mybridge:LR_thermostat:speedFanCoil" }
String iLR_thermostat_setMode "Mode" (gLivingRoom) { channel="openwebnet:bus_thermostat:mybridge:LR_thermostat:mode" }
String iLR_thermostat_setFunc "Function" (gLivingRoom) { channel="openwebnet:bus_thermostat:mybridge:LR_thermostat:function" }
Number:Temperature iEXT_temp "Temperature [%.1f °C]" <temperature> (gExternal) { channel="openwebnet:bus_temp_sensor:mybridge:EXT_tempsensor:temperature" }


```

Expand Down Expand Up @@ -212,6 +240,15 @@ sitemap openwebnet label="OpenWebNet Binding Example Sitemap"
Default item=iCENTRAL_Ta label="General" icon="energy" valuecolor=[>3000="red"]
Default item=iCENTRAL_Tb label="Ground Floor" icon="energy" valuecolor=[>3000="red"]
}

Frame label="Thermoregulation"
{
Default item=iLR_thermostat_temp label="Temperature" icon="fire" valuecolor=[<20="red"]
Setpoint item=iLR_thermostat_set label="Setpoint [%.1f °C]" step=0.5 minValue=15 maxValue=30
Selection item=iLR_thermostat_setFanSpeed label="Fan Speed" icon="fan" mappings=[AUTO="AUTO", SPEED_1="Low", SPEED_2="Medium", SPEED_3="High"]
Switch item=iLR_thermostat_setMode label="Mode" icon="settings"
Selection item=iLR_thermostat_setFunc label="Function" icon="heating" mappings=[HEATING="Heating", COOLING="Cooling", GENERIC="Heating/Cooling"]
}
}
```

Expand Down
2 changes: 1 addition & 1 deletion bundles/org.openhab.binding.openwebnet/pom.xml
Original file line number Diff line number Diff line change
Expand Up @@ -23,7 +23,7 @@
<dependency>
<groupId>io.github.openwebnet4j</groupId>
<artifactId>openwebnet4j</artifactId>
<version>0.4.1</version>
<version>0.5.2</version>
<scope>compile</scope>
</dependency>

Expand Down