#### Why I did it
Dropping control character (message sent when XSUB connects to XPUB as part of ZMQ Proxy setup to notify that subscription has been made) in do capture has been flaky since control character is not guaranteed to be the first message sent if there are events (like event-down-ctr) being published to XSUB.
Scenarios
1) Control character is sent and is first message when starting capture service
`eventd#eventd#eventd: :- heartbeat_ctrl: Set heartbeat_ctrl pause=1`
`eventd#eventd#eventd: :- do_capture: Received subscription message when XSUB connects to XPUB`
2) Events like event-down ctr is sent before control character
`eventd#eventd#eventd: :- run: Dropping Message: 22 serialization::archive 18 17 sonic-events-host`
`eventd#eventd#eventd: :- run: Dropping Message: 22 serialization::archive 18 0 0 4 0 0 0 1 d 103 {"sonic-events-host:event-stopped-ctr":{"ctr_name":"EVENTD","timestamp":"2024-08-27T00:02:51.407518Z"}} 1 r 36 3357542f-bae1-458f-a804-660e620d21f5 1 s 1 9 1 t 19 1724716971407591080`
`heartbeat_ctrl: Set heartbeat_ctrl pause=1`
`do_capture: Received subscription message when XSUB connects to XPUB`
3) Control character is not sent at all
`eventd#eventd#eventd: :- heartbeat_ctrl: Set heartbeat_ctrl pause=1`
4) Control character is delayed and not caught when starting capture service, but is then caught after causing deserialize error.
`do_capture: Receiving event from source: 22 serialization::archive 18 17 sonic-events-host, will read second part of event`
`deserialize: deserialize Failed: input stream errorstr[0:64]:(sonic-net#1) data type: std::__cxx11::basic_string<char, std::char_traits<char>, std::allocator<char> >&`
`zmq_read_part: Failed to deserialize part rc=-2`
`zmq_read_part: last:errno=11`
`zmq_message_read: Failure to read part1 rc=-2`
`zmq_message_read: last:errno=11`
We can cover these scenarios by just dropping the control character inside zmq_message_read as part of events_common in swsscommon (different PR). In this PR we will remove such handling logic and make sure that empty events that will be sent by control character are ignored.
##### Work item tracking
- Microsoft ADO **(number only)**:28728116
#### How I did it
Remove logic for handling control character
#### How to verify it
UT and sonic-mgmt test cases.