Notifications
You must be signed in to change notification settings - Fork 664
New issue
Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.
By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.
Already on GitHub? Sign in to your account
[drop counters] Fix CLI script for unconfigured PGs #2518
Merged
liat-grozovik
merged 1 commit into
sonic-net:master
from
liorghub:fix_show_pg_drop_counters
Nov 29, 2022
Merged
[drop counters] Fix CLI script for unconfigured PGs #2518
liat-grozovik
merged 1 commit into
sonic-net:master
from
liorghub:fix_show_pg_drop_counters
Nov 29, 2022
Conversation
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
nazariig
approved these changes
Nov 28, 2022
@liorghub on which branches this need to be fixed? please specify so we can add the right labels. |
liat-grozovik
approved these changes
Nov 28, 2022
@liat-grozovik This PR should be merged to branch 202211 as well. |
liat-grozovik
approved these changes
Nov 29, 2022
@liat-grozovik @dprital |
yxieca
pushed a commit
that referenced
this pull request
Dec 1, 2022
- What I did Since PG counters are created only if they are configured in the switch, it is not enough to relay only on the first entry in the DB when building the output table of watermarkstat script. We need to go over all configured counters, check what is the max configured and build the table accordingly. - How I did it Iterate all configured PG buffers for all ports and find the max index. Build the output table according to the max index. - How to verify it Run test "pgdropstat_test.py" including this PR and observe it passes.
preetham-singh
pushed a commit
to preetham-singh/sonic-utilities
that referenced
this pull request
Dec 6, 2022
- What I did Since PG counters are created only if they are configured in the switch, it is not enough to relay only on the first entry in the DB when building the output table of watermarkstat script. We need to go over all configured counters, check what is the max configured and build the table accordingly. - How I did it Iterate all configured PG buffers for all ports and find the max index. Build the output table according to the max index. - How to verify it Run test "pgdropstat_test.py" including this PR and observe it passes.
7 tasks
dprital
added a commit
to dprital/sonic-buildimage
that referenced
this pull request
Dec 6, 2022
Update sonic-utilities submodule pointer to include the following: * ca9a020 [generate_dump] [Mellanox] Fix the duplicate dfw dump collection problem by adding symlinks ([sonic-net#2536](sonic-net/sonic-utilities#2536)) * 92c7001 [config] Add check in config interface ip command to block if the interface is portchannel member ([sonic-net#2539](sonic-net/sonic-utilities#2539)) * e8130f5 [system-health] Improve code structure of system health CLIs ([sonic-net#2453](sonic-net/sonic-utilities#2453)) * 00c01b3 Transceiver eeprom dom CLI modification to show output from TRANSCEIVER_DOM_THRESHOLD table ([sonic-net#2535](sonic-net/sonic-utilities#2535)) * 42f51c2 sonic-utilities: Update config reload() to verify formatting of an input file ([sonic-net#2529](sonic-net/sonic-utilities#2529)) * a5e1e2b [GCU] Add RemoveCreateOnlyDependency Validator/Generator ([sonic-net#2500](sonic-net/sonic-utilities#2500)) * 6411b52 [QoS] Introduce delay to the qos reload flow ([sonic-net#2503](sonic-net/sonic-utilities#2503)) * fce7ec3 Use github code scanning instead of LGTM ([sonic-net#2530](sonic-net/sonic-utilities#2530)) * 91bd6de Change show kube command default value of insecure key to True ([sonic-net#2517](sonic-net/sonic-utilities#2517)) * c44c584 Add db_migrator_constants.py script to setup.py ([sonic-net#2534](sonic-net/sonic-utilities#2534)) * 6a3238e [drop counters] Fix CLI script for unconfigured PGs ([sonic-net#2518](sonic-net/sonic-utilities#2518)) * 263810b Update vrf add, del commands for duplicate/non-existing VRFs ([sonic-net#2467](sonic-net/sonic-utilities#2467)) * addae73 Port 202012 DB migration changes to newer branches ([sonic-net#2515](sonic-net/sonic-utilities#2515)) * 2af8cfa [VXLAN]Fixing traceback in show remotemac when mac moves during command execution ([sonic-net#2506](sonic-net/sonic-utilities#2506)) Signed-off-by: dprital <drorp@nvidia.com>
8 tasks
StormLiangMS
pushed a commit
that referenced
this pull request
Dec 30, 2022
- What I did Since PG counters are created only if they are configured in the switch, it is not enough to relay only on the first entry in the DB when building the output table of watermarkstat script. We need to go over all configured counters, check what is the max configured and build the table accordingly. - How I did it Iterate all configured PG buffers for all ports and find the max index. Build the output table according to the max index. - How to verify it Run test "pgdropstat_test.py" including this PR and observe it passes.
Sign up for free
to join this conversation on GitHub.
Already have an account?
Sign in to comment
Labels
Add this suggestion to a batch that can be applied as a single commit.
This suggestion is invalid because no changes were made to the code.
Suggestions cannot be applied while the pull request is closed.
Suggestions cannot be applied while viewing a subset of changes.
Only one suggestion per line can be applied in a batch.
Add this suggestion to a batch that can be applied as a single commit.
Applying suggestions on deleted lines is not supported.
You must change the existing code in this line in order to create a valid suggestion.
Outdated suggestions cannot be applied.
This suggestion has been applied or marked resolved.
Suggestions cannot be applied from pending reviews.
Suggestions cannot be applied on multi-line comments.
Suggestions cannot be applied while the pull request is queued to merge.
Suggestion cannot be applied right now. Please check back later.
What I did
Since PG counters are created only if they are configured in the switch, it is not enough to relay only on the first entry in the DB when building the output table of watermarkstat script.
We need to go over all configured counters, check what is the max configured and build the table accordingly.
How I did it
Iterate all configured PG buffers for all ports and find the max index.
Build the output table according to the max index.
How to verify it
Run test "pgdropstat_test.py" including this PR and observe it passes.
Previous command output (if the output of a command-line utility has changed)
New command output (if the output of a command-line utility has changed)