https://github.com/wmo-im/tt-wigosmd/wiki/Meeting.2024.10.24 notes: |
Notation: pT2.Hz-1 |
https://github.com/wmo-im/tt-wigosmd/wiki/Meeting.2024.11.21 notes: |
https://github.com/wmo-im/tt-wigosmd/wiki/Meeting.2024.12.13 notes: |
@gaochen-larc have you updated this proposal? |
I put the proposal in amendment details. should I put it in a table? |
Thanks! I think you did it correctly. Will you have time to update the branch? |
Just add these two units to Table 1-02. Hope I did correctly |
https://github.com/wmo-im/tt-wigosmd/wiki/Meeting.2025.01.16 notes:
|
@gaochen-larc @amilan17 I have the feeling that these units are actually not addressing the issue. From my reading (and I am not an expert), there is the magnetic and the electrical dimension of Schumann resonances. I have found more information (including from Wikipedia) about the electrical dimension. For that, the units should be microvolts per meter. Why did you propose a unit for magnetic fields? |
I proposed these units per initial request. I have also seen these units used in a few papers on Schumann resonances. |
|
I guess we just need to incorporate the oscar unit into the WIGOS code. Should we use use the OSCAR definition? |
https://github.com/wmo-im/tt-wigosmd/wiki/Meeting.2025.02.20 notes: |
Initial request
Align the units in OSCAR Requirements and WIGOS units.
Add unit pT2 Hz-1 for Schumann Resonances (Measurement unit Table 1-02) as used in the Schumann Resonances variable at https://space.oscar.wmo.int/variables/view/schumann_resonances
Amendment details
Add the following to the unit table:
Notation: pT2.Hz-1
Name: picoTesla squared per Hertz
Description: SI derived unit for magnetic power spectrum commonly used to describe Schumann Resonances. SI base unit equivalent: 1E-12 A m-1 s.
Notation: nT2.Hz-1
Name: nanoTesla squared per Hertz
Description: SI derived unit for magnetic power spectrum commonly used to describe Schumann Resonances. SI base unit equivalent: 1E-9 A m-1 s.
Requestor(s)
GCOS, OSCAR Requirements, @kpremec
Stakeholder(s)
Enter list of stakeholder(s).
Applications or Systems
Expected impact of change
None
Collaborators
No response
References
No response
Comments
related to this issue: #548
Publication(s)
Manual on Codes (WMO-No. 306), Volume I.3, WMO Codes Registry - WMDR
Validation
No response