Notifications
You must be signed in to change notification settings - Fork 1.7k
Satel Alarm Binding
This is documentation of openHAB binding for Satel Integra Alarm System which allows you to connect to your alarm system using TCP/IP protocol with ETHM-1 module installed or RS-232 protocol with INT-RS module installed.
For installation of the binding, please see Wiki page Bindings.
NOTE: INT-RS module is supported since version 1.8 of the binding.
There are some configuration settings that you can set in the openhab.cfg file. Include the following in your openhab.cfg.
############################### Satel Binding ###################################
#
# Satel ETHM-1 module hostname or IP.
# Leave this commented out for INT-RS module.
#satel:host=
# ETHM-1 port to use (optional, defaults to 7094), if host setting is not empty.
# INT-RS port to use, if host setting is empty.
#satel:port=7094
# timeout value for both ETHM-1 and INT-RS (optional, in milliseconds, defaults to 5000)
#satel:timeout=5000
# refresh value (optional, in milliseconds, defaults to 10000)
#satel:refresh=10000
# user code for Integra control (optional, if empty binding works in read-only mode)
#satel:user_code=
# encryption key (optional, if empty communication is not encrypted)
#satel:encryption_key=
The only required parameter is satel:host for the ETHM-1 module and satel:port for the INT-RS module. The rest default to the values described in the configuration comments. In order to use ETHM-1 module it is required to enable "integration" protocol for the module in Integra configuration (DLOADX).
Option | Description |
---|---|
satel:host | Valid only for ETHM-1 module. Specifies either IP or host name of the module |
satel:port | For INT-RS it specifies the serial port on the host system to which the module is connected, i.e. "COM1" on Windows, "/dev/ttyS0" or "/dev/ttyUSB0" on Linux For ETHM-1 it specifies the TCP port on which the module listens for new connections. Defaults to 7094. |
satel:timeout | Timeout value for connect, read and write operations specified in milliseconds. Defaults to 5 seconds |
satel:refresh | Refresh interval in milliseconds. Defaults to 10 seconds. |
satel:user_code | Security code (password) of the user used for control operations, like arming, changing state of outputs, etc. It is recommended to use dedicated user for openHAB integration. |
satel:encryption_key | Key use for encrypting communication between openHAB and ETHM-1 module. To disable encrytpion leave it empty. See also the note below. |
NOTE: Encryption requires support for 192 bit AES keys. Oracle Java by default supports only 128 bit keys, therefore "Java Cryptography Extension (JCE) Unlimited Strength Jurisdiction Policy Files" must be installed. OpenJDK supports unlimited AES keys by default.
NOTE: As of version 2.03 ETHM-1 Plus firmware the module disconnects after 25 seconds of inactivity. Setting
satel:refresh
to value greater than 25000 will cause inability to correctly communicate with the module.
In order to bind to the Integra Alarm system you need to add settings for items defined in your item file. Here is item configuration string syntax:
satel="<object_type>[:<state_type>][:<object_number>,...][:<option>=<value>,...]"
Name of object type, state type and option is case insensitive. For "output" objects state type cannot be specified and must be ommited. object_number
must be integer number in range 1-256. Options are comma-separated pairs of name and value separated by =
character.
Supported item types: Contact
, Switch
, Number
, Rollershutter
.
For all but Rollershutter
item type only one object_number
is allowed. For Rollershutter
item there must be exactly two object numbers specified. As there is no information about roller shutter position, state is updated to 0% when "UP" command is received and 100% when "DOWN" command is received, assuming the state will be eventually reached.
Number items can be used only if object_number
is not given and the number specifies cardinality of objects that are in given state. For example if object is "zone" and state is "violated", item will tell you number of zones violated. See examples section for detailed configuration syntax.
Valid object_type
values:
Type | Description |
---|---|
zone | defines a zone: PIR, contact, etc. |
partition | defines a partition |
output | defines an output |
doors | defines doors |
status | defines a status item |
module | defines connection status item |
trouble | defines a trouble |
trouble_memory | defines memory of a trouble |
Valid state_type
values for "zone" objects:
NOTE: Sending commands to zones is available since v1.9 of the binding
Type | Notes |
---|---|
violation | |
tamper | |
alarm | |
tamper_alarm | |
alarm_memory | |
tamper_alarm_memory | |
bypass | ON command bypasses the zone, OFF unbypasses. |
no_violation_trouble | |
long_violation_trouble | |
isolate | ON command isolates the zone. |
masked | |
masked_memory |
Valid state_type
values for "partition" objects:
Type | Notes |
---|---|
armed | ON command arms specified partition in mode 0, OFF disarms. Forces arming if "force_arm" option is specified. |
really_armed | ON command arms specified partition in mode 0, OFF disarms. Forces arming if "force_arm" option is specified. |
armed_mode_1 | ON command arms specified partition in mode 1, OFF disarms. Forces arming if "force_arm" option is specified. |
armed_mode_2 | ON command arms specified partition in mode 2, OFF disarms. Forces arming if "force_arm" option is specified. |
armed_mode_3 | ON command arms specified partition in mode 3, OFF disarms. Forces arming if "force_arm" option is specified. |
first_code_entered | |
entry_time | |
exit_time_gt_10 | |
exit_time_lt_10 | |
temporary_blocked | |
blocked_for_guard | |
alarm | OFF command clears alarms for specified partition |
alarm_memory | OFF command clears alarms for specified partition |
fire_alarm | OFF command clears alarms for specified partition |
fire_alarm_memory | OFF command clears alarms for specified partition |
violated_zones | |
verified_alarms | OFF command clears alarms for specified partition |
warning_alarms | OFF command clears alarms for specified partition |
Valid state_type
values for "doors" objects:
NOTE: Sending commands to doors is available since v1.9 of the binding
Type | Notes |
---|---|
opened | ON command opens the doors. |
opened_long |
Valid state_type
values for "status" objects:
Type | Notes |
---|---|
service_mode | |
troubles | OFF command clears troubles memory |
troubles_memory | OFF command clears troubles memory |
acu100_present | |
intrx_present | |
grade23_set | |
date_time | DateTimeType or StringType command changes Integra date and time |
Valid state_type
values for "module" objects:
Type | Notes |
---|---|
connected | status of connection to the module |
connected_since | date and time when current connection has been established |
connection_errors | number of consecutive connection errors; clears on successful connection |
Valid state_type
values for "trouble" objects:
NOTE: Available since v1.10
Type | Notes |
---|---|
technical_zone | object number range: 1-128 |
expander_ac | object number range: 1-64 |
expander_batt | object number range: 1-64 |
expander_nobatt | object number range: 1-64 |
system | object number range: 1-24, see table below |
ptsa_ac | AC trouble of CA-64 PTSA modules, object number range: 1-8 |
ptsa_batt | BATT trouble of CA-64 PTSA modules, object number range: 1-8 |
ptsa_nobatt | NO BATT trouble of CA-64 PTSA modules, object number range: 1-8 |
ethm1 | object number range: 1-8 |
proximity_a | object number range: 1-64 |
proximity_b | object number range: 1-64 |
expander_overload | object number range: 1-64 |
jammed_acu100 | object number range: 1-16 |
device_lobatt | object number range: 1-120 |
device_nocomm | object number range: 1-120 |
output_nocomm | object number range: 1-120 |
expander_nocomm | object number range: 1-64 |
expander_switcherooed | object number range: 1-64 |
keypad_nocomm | object number range: 1-8 |
keypad_switcherooed | object number range: 1-8 |
ethm1_nolan | object number range: 1-8 |
expander_tamper | object number range: 1-64 |
keypad_tamper | object number range: 1-8 |
keypad_init | object number range: 1-8 |
auxiliary_stm | object number range: 1-8 |
master_keyfob | object number range: 1-8 |
user_keyfob | object number range: 1-240 |
device_lobatt1 | for Integra 256 Plus - last 120 devices, object number range: 1-120 |
device_nocomm1 | for Integra 256 Plus - last 120 devices, object number range: 1-120 |
output_nocomm1 | for Integra 256 Plus - last 120 devices, object number range: 1-120 |
technical_zone1 | for Integra 256 Plus - zones 129..256, object number range: 1-128 |
Valid state_type
values for "trouble_memory" objects:
NOTE: Available since v1.10
Type | Notes |
---|---|
technical_zone | object number range: 1-128 |
expander_ac | object number range: 1-64 |
expander_batt | object number range: 1-64 |
expander_nobatt | object number range: 1-64 |
system | object number range: 1-24, see table below |
ptsa_ac | AC trouble of CA-64 PTSA modules, object number range: 1-8 |
ptsa_batt | BATT trouble of CA-64 PTSA modules, object number range: 1-8 |
ptsa_nobatt | NO BATT trouble of CA-64 PTSA modules, object number range: 1-8 |
ethm1 | object number range: 1-8 |
proximity_a | object number range: 1-64 |
proximity_b | object number range: 1-64 |
expander_overload | object number range: 1-64 |
jammed_acu100 | object number range: 1-16 |
lcd_restart | object number range: 1-8 |
expander_restart | object number range: 1-64 |
device_lobatt | object number range: 1-120 |
device_nocomm | object number range: 1-120 |
output_nocomm | object number range: 1-120 |
expander_nocomm | object number range: 1-64 |
expander_switcherooed | object number range: 1-64 |
keypad_nocomm | object number range: 1-8 |
keypad_switcherooed | object number range: 1-8 |
ethm1_nolan | object number range: 1-8 |
expander_tamper | object number range: 1-64 |
keypad_tamper | object number range: 1-8 |
keypad_init | object number range: 1-8 |
auxiliary_stm | object number range: 1-8 |
long_violation | object number range: 1-128 |
no_violation | object number range: 1-128 |
zone_tamper | object number range: 1-128 |
technical_zone1 | for Integra 256 Plus - zones 129..256, object number range: 1-128 |
user_keyf | | object number range: 1-240 |
device_lobatt1 | for Integra 256 Plus - last 120 devices, object number range: 1-120 |
device_nocomm1 | for Integra 256 Plus - last 120 devices, object number range: 1-120 |
output_nocomm1 | for Integra 256 Plus - last 120 devices, object number range: 1-120 |
long_violation1 | for Integra 256 Plus - zones 129..256, object number range: 1-128 |
no_violation1 | for Integra 256 Plus - zones 129..256, object number range: 1-128 |
zone_tamper1 | for Integra 256 Plus - zones 129..256, object number range: 1-128 |
System troubles:
Number | Description |
---|---|
1 | OUT1 trouble |
2 | OUT2 trouble |
3 | OUT3 trouble |
4 | OUT4 trouble |
5 | +KPD trouble |
6 | +EX1 or +EX2 trouble |
7 | BATT trouble |
8 | AC trouble |
9 | DT1 trouble |
10 | DT2 trouble |
11 | DTM trouble |
12 | RTC trouble |
13 | no DTR signal |
14 | no BATT present |
15 | external modem initialization trouble |
16 | external model command (ATE0V1Q0H0S0=0) trouble |
17 | no voltage on telephone line (INTEGRA 24, 32, 64 and 128) |
17 | auxiliary ST processor trouble (INTEGRA 128-WRL) |
18 | bad signal on telephone line |
19 | no signal on telephone line |
20 | monitoring to station 1 trouble |
21 | monitoring to station 2 trouble |
22 | EEPROM or access to RTC trouble |
23 | RAM memory trouble |
24 | INTEGRA main panel restart memory |
Valid options:
Name | Description |
---|---|
force_arm | forces arming for arming commands |
commands_only | item accepts commands, but state of the item is not updated |
invert_state | uses 0 as active state (zones and outputs only) |
Available as of openHAB 1.9
NOTE: Satel Binding v1.9+ must be installed in order to use Satel Actions
The Satel Action bundle provides actions to read event log of the connected alarm system, check current connection status and override configured user code.
-
boolean satelIsConnected()
- returnstrue
if connected to communication module andfalse
otherwise -
Object[] satelReadEvent(int eventIndex)
- reads event log record for given index; records must be read one by one from most recent record under index-1
; see record description below -
String satelReadDeviceName(String deviceType, int deviceNumber)
- reads description of a device; device type must be one of PARTITION, ZONE, USER, EXPANDER, LCD, OUTPUT, TIMER, TELEPHONE, OBJECT -
void satelSetUserCode(String newUserCode)
- overrides configured user code to a given one; allows to execute commands not available for default user configured in the settings -
void satelResetUserCode()
- reverts user code set bysatelSetUserCode(String newUserCode)
to the value configured in openhab.cfg/satel.cfg.
Event record fields:
Field | Type | Description |
---|---|---|
timestamp | DateTimeType | time when the event happened |
partition | Integer | partition number |
event class | Enum | one of ZONE_ALARMS, PARTITION_ALARMS, ARMING, BYPASSES, ACCESS_CONTROL, TROUBLES, USER_FUNCTIONS, SYSTEM_EVENTS |
event code | Integer | code of the event |
restoration flag | Boolean | |
event description | String | |
kind of description | Integer | |
source | Integer | |
object | Integer | |
user control number | Integer | |
next event index | Integer | index that must be passed to read next record from the log |
current event index | Integer | index of the current record |
Partition item with ability to arm and disarm:
Switch PartitionArmed "Partition armed" { satel="partition:armed:1" }
Sitemap definitions for above example. The second one allows only to arm the partition:
Switch item=PartitionArmed
Switch item=PartitionArmed mappings=[ON="Arm"]
Partition item with ability to force arming:
Switch Partition1 "Partition armed" { satel="partition:armed:1:force_arm" }
Simple contact item:
Contact Zone1 "Zone #1 violated" { satel="zone:violation:1" }
Zone bypass status with ability to change the state:
Switch Zone1 "Zone #1 bypass" { satel="zone:bypass:1" }
Number of zones violated:
Number ZonesViolated "Zones violated [%d]" { satel="zone:violation" }
Simple output item with ability to change its state:
Switch Output1 "Output #1" { satel="output:1" }
Number of partitions with "alarm" state:
Number PartitionsInAlarm "Partitions alarmed [%d]" { satel="partition:alarm" }
Troubles memory item with clear ability:
Switch TroublesMemory "Troubles in the system" { satel="status:troubles_memory" }
Roller shutter item:
Rollershutter KitchenBlinds "Kitchen blinds" { satel="output:10,11" }
Doors open/closed status with ability to open them:
Switch Doors1 "Doors #1" { satel="doors:opened:1" }
Time synchronization using NTP binding:
DateTime AlarmDateTime "Current time [%1$tF %1$tR]" { satel="status:date_time" }
DateTime NtpDateTime "NTP time [%1$tF %1$tR]" {ntp="Europe/Berlin:de_DE" }
Rule for above example:
rule "Alarm time sync"
when
Item NtpDateTime received update
then
AlarmDateTime.sendCommand(new StringType(NtpDateTime.state.toString))
end
Connection status, item definition:
Switch AlarmConnection "Connection status" <network> { satel="module:connected" }
DateTime AlarmConnSince "Connected since [%1$tF %1$tR]" { satel="module:connected_since" }
Rule to send email on each alarm with 10 most recent records from the event log:
rule "Satel Action test"
when
AlarmPart1 changed to ON
then
var Integer eventIdx = -1
var String details
var String msgBody = ""
if (satelIsConnected()) {
logInfo("EventLog", "Start")
(1..10).forEach[
val Object[] eventRec = satelReadEvent(eventIdx)
val kind = eventRec.get(6) as Integer
val source = eventRec.get(7) as Integer
val object = eventRec.get(8) as Integer
val ucn = eventRec.get(9) as Integer
if (kind == 0) {
details = ""
} else if (kind == 1) {
details = ", partition: " + satelReadDeviceName("PARTITION", eventRec.get(1)) + ", zone: " + satelReadDeviceName("ZONE", source)
} else if (kind == 2) {
details = ", partition: " + satelReadDeviceName("PARTITION", eventRec.get(1)) + ", user: " + satelReadDeviceName("USER", source)
} else if (kind == 4) {
if (source == 0) {
details = " (mainboard)"
} else if (source <= 128) {
details = ", zone: " + satelReadDeviceName("ZONE", source)
} else if (source <= 192) {
details = ", expander: " + satelReadDeviceName("EXPANDER", source)
} else {
details = ", lcd: " + satelReadDeviceName("LCD", source)
}
} else if (kind == 5) {
details = ", partition: " + satelReadDeviceName("PARTITION", eventRec.get(1))
} else if (kind == 6) {
details = ", keypad: " + satelReadDeviceName("LCD", eventRec.get(1)) + ", user: " + satelReadDeviceName("USER", source)
} else if (kind == 7) {
details = ", user: " + satelReadDeviceName("USER", source)
} else if (kind == 15) {
details = ", partition: " + satelReadDeviceName("PARTITION", eventRec.get(1)) + ", timer: " + satelReadDeviceName("TIMER", source)
} else if (kind == 30) {
details = ", keypad: " + satelReadDeviceName("LCD", eventRec.get(1)) + ", ip: " + source + "." + (object*32 + ucn) + details
} else if (kind == 31) {
details = "." + source + "." + (object*32 + ucn)
} else {
details = ", kind=" + kind + ", partition=" + eventRec.get(1) + ", source=" + source + ", object=" + object + ", ucn=" + ucn
}
if (kind != 31) {
msgBody = msgBody + "\n" + eventRec.get(0) + ": " + eventRec.get(5) + details
}
eventIdx = eventRec.get(10)
]
logInfo("EventLog", "End")
sendMail("you@email.net", "Even log", msgBody)
}
end
Item definition for the above rule:
Switch AlarmPart1 "Alarm on partition #1" { satel="partition:alarm_memory:1" }
Rule that changes user code for 10 minutes. After that time user code is reverted to the one configured in openhab.cfg
.
var String userCode = ""
var Timer keypadTimer = null
var Timer userCodeTimer = null
rule "Keypad char entered"
when
Item Keypad_Char changed
then
if (Keypad_Char.state == "-") {
satelSetUserCode(userCode)
userCode = ""
if (userCodeTimer != null) {
userCodeTime.cancel
}
userCodeTimer = createTimer(now.plusMinutes(10)) [|
logInfo("Keypad", "Reverting user code")
satelResetUserCode()
]
} else if (Keypad_Char.state == "*") {
satelResetUserCode()
userCode = ""
} else {
userCode = userCode + Keypad_Char.state
}
if (keypadTimer != null) {
keypadTimer.cancel
}
keypadTimer = createTimer(now.plusSeconds(5)) [|
userCode = ""
Keypad_Char.postUpdate("")
]
end
Item definition for above rule:
String Keypad_Char ">"
Sitemap keypad to enter user code for above rule:
Text label="Enter user code" icon="settings" {
Switch item=Keypad_Char mappings=[ "1"="1", "2"="2", "3"="3" ]
Switch item=Keypad_Char mappings=[ "4"="4", "5"="5", "6"="6" ]
Switch item=Keypad_Char mappings=[ "7"="7", "8"="8", "9"="9" ]
Switch item=Keypad_Char mappings=[ "*"="*", "0"="0", "-"="#" ]
}
User for OH integration
To control Integra partitions and outputs you need to provide security code of user in behalf all those operations will be executed. It is highly recommended to use a separate user for openHAB integration with only required access rights set in Integra configuration, like access to certain partitions, etc. This allows you to distinguish actions made by OH and a user using Integra panel, also it will block unwanted operations in case someone breaks into your local network.
Disarming and clearing alarms
Although this binding allows you to configure disarming a partition and clearing alarms for a partion, this should be used only in cases when security is not the priority. Don't forget both these operations can be executed in openHAB without specifying user code, which is required to disarm or clear alarms using Integra panel. Consider adding a keypad in your sitemap to temporarily change user code to execute sensitive operations. You can find such keypad in examples section. Also don't forget to secure your openHAB installation by using HTTPS protocol and setting a user with password. Here is a page about security in openHAB: Security
- troubles support (detailed)
ℹ Please find all documentation for openHAB 2 under http://docs.openhab.org.
The wiki pages here contain (outdated) documentation for the older openHAB 1.x version. Please be aware that a lot of core details changed with openHAB 2.0 and this wiki as well as all tutorials found for openHAB 1.x might be misleading. Check http://docs.openhab.org for more details and consult the community forum for all remaining questions.
- Classic UI
- iOS Client
- Android Client
- Windows Phone Client
- GreenT UI
- CometVisu
- Kodi
- Chrome Extension
- Alfred Workflow
- Cosm Persistence
- db4o Persistence
- Amazon DynamoDB Persistence
- Exec Persistence
- Google Calendar Presence Simulator
- InfluxDB Persistence
- JDBC Persistence
- JPA Persistence
- Logging Persistence
- mapdb Persistence
- MongoDB Persistence
- MQTT Persistence
- my.openHAB Persistence
- MySQL Persistence
- rrd4j Persistence
- Sen.Se Persistence
- SiteWhere Persistence
- AKM868 Binding
- AlarmDecoder Binding
- Anel Binding
- Arduino SmartHome Souliss Binding
- Asterisk Binding
- Astro Binding
- Autelis Pool Control Binding
- BenQ Projector Binding
- Bluetooth Binding
- Bticino Binding
- CalDAV Binding
- Chamberlain MyQ Binding
- Comfo Air Binding
- Config Admin Binding
- CUL Transport
- CUL Intertechno Binding
- CUPS Binding
- DAIKIN Binding
- Davis Binding
- DD-WRT Binding
- Denon Binding
- digitalSTROM Binding
- DIY on XBee Binding
- DMX512 Binding
- DSC Alarm Binding
- DSMR Binding
- eBUS Binding
- Ecobee Binding
- EDS OWSever Binding
- eKey Binding
- Energenie Binding
- EnOcean Binding
- Enphase Energy Binding
- Epson Projector Binding
- Exec Binding
- Expire Binding
- Fatek PLC Binding
- Freebox Binding
- Freeswitch Binding
- Frontier Silicon Radio Binding
- Fritz AHA Binding
- Fritz!Box Binding
- FritzBox-TR064-Binding
- FS20 Binding
- Garadget Binding
- Global Caché IR Binding
- GPIO Binding
- HAI/Leviton OmniLink Binding
- HDAnywhere Binding
- Heatmiser Binding
- Homematic / Homegear Binding
- Horizon Mediabox Binding
- HTTP Binding
- IEC 62056-21 Binding
- IHC / ELKO Binding
- ImperiHome Binding
- Insteon Hub Binding
- Insteon PLM Binding
- IPX800 Binding
- IRtrans Binding
- jointSPACE-Binding
- KM200 Binding
- KNX Binding
- Koubachi Binding
- LCN Binding
- LightwaveRF Binding
- Leviton/HAI Omnilink Binding
- Lg TV Binding
- Logitech Harmony Hub
- MailControl Binding
- MAX!Cube-Binding
- MAX! CUL Binding
- MCP23017 I/O Expander Binding
- MCP3424 ADC Binding
- MiLight Binding
- MiOS Binding
- Mochad X10 Binding
- Modbus Binding
- MPD Binding
- MQTT Binding
- MQTTitude binding
- MystromEcoPower Binding
- Neohub Binding
- Nest Binding
- Netatmo Binding
- Network Health Binding
- Network UPS Tools Binding
- Nibe Heatpump Binding
- Nikobus Binding
- Novelan/Luxtronic Heatpump Binding
- NTP Binding
- One-Wire Binding
- Onkyo AV Receiver Binding
- Open Energy Monitor Binding
- OpenPaths presence detection binding
- OpenSprinkler Binding
- OSGi Configuration Admin Binding
- Panasonic TV Binding
- panStamp Binding
- Philips Hue Binding
- Picnet Binding
- Piface Binding
- PiXtend Binding
- pilight Binding
- Pioneer-AVR-Binding
- Plex Binding
- Plugwise Binding
- PLCBus Binding
- PowerDog Local API Binding
- Powermax alarm Binding
- Primare Binding
- Pulseaudio Binding
- Raspberry Pi RC Switch Binding
- RFXCOM Binding
- RWE Smarthome Binding
- Sager WeatherCaster Binding
- Samsung AC Binding
- Samsung TV Binding
- Serial Binding
- Sallegra Binding
- Satel Alarm Binding
- Siemens Logo! Binding
- SimpleBinary Binding
- Sinthesi Sapp Binding
- Smarthomatic Binding
- Snmp Binding
- Somfy URTSI II Binding
- Sonance Binding
- Sonos Binding
- Souliss Binding
- Squeezebox Binding
- Stiebel Eltron Heatpump
- Swegon ventilation Binding
- System Info Binding
- TA CMI Binding
- TCP/UDP Binding
- Tellstick Binding
- TinkerForge Binding
- Tivo Binding
- UCProjects.eu Relay Board Binding
- UPB Binding
- VDR Binding
- Velleman-K8055-Binding
- Wago Binding
- Wake-on-LAN Binding
- Waterkotte EcoTouch Heatpump Binding
- Weather Binding
- Wemo Binding
- Withings Binding
- XBMC Binding
- xPL Binding
- Yamahareceiver Binding
- Zibase Binding
- Z-Wave Binding
- Asterisk
- DoorBird
- FIND
- Foscam IP Cameras
- LG Hombot
- Worx Landroid
- Heatmiser PRT Thermostat
- Google Calendar
- Linux Media Players
- Osram Lightify
- Rainforest EAGLE Energy Access Gateway
- Roku Integration
- ROS Robot Operating System
- Slack
- Telldus Tellstick
- Zoneminder
- Wink Hub (rooted)
- Wink Monitoring
- openHAB Cloud Connector
- Google Calendar Scheduler
- Transformations
- XSLT
- JSON
- REST-API
- Security
- Service Discovery
- Voice Control
- BritishGasHive-Using-Ruby
- Dropbox Bundle
A good source of inspiration and tips from users gathered over the years. Be aware that things may have changed since they were written and some examples might not work correctly.
Please update the wiki if you do come across any out of date information.
- Rollershutter Bindings
- Squeezebox
- WAC Binding
- WebSolarLog
- Alarm Clock
- Convert Fahrenheit to Celsius
- The mother of all lighting rules
- Reusable Rules via Functions
- Combining different Items
- Items, Rules and more Examples of a SmartHome
- Google Map
- Controlling openHAB with Android
- Usecase examples
- B-Control Manager
- Spell checking for foreign languages
- Flic via Tasker
- Chromecast via castnow
- Speedtest.net integration