Previous logic of the ioc had this logic for sending mode params:
This logic is probably in connection with changing from PULSE to none PULSE versions of the MODE setpoint. The calculation part probably takes care of switching to the right mode with respect to the specified order of modes in the mbbo in record MODE:SP
In db file at aeroflexSup\aeroflex_2023A.db
record(calcout, "$(P)SEND_MODE_PARAMS")
{
field(DESC, "Set modulation button")
field(SCAN, "Passive")
field(INPA, "$(P)MODE:SP_NO_ACTION")
field(INPB, "$(P)PULSE_CHECK:SP")
field(CALC, "(B = 0) ? ((2 * A) + 1) : (2 * A)")
field(OUT, "$(P)MODE:SP PP")
}
In db file at aeroflexSup\aeroflex_2030.db
record(calcout, "$(P)SEND_MODE_PARAMS")
{
field(DESC, "Set modulation button")
field(SCAN, "Passive")
field(INPA, "$(P)MODE:SP_NO_ACTION")
field(INPB, "$(P)PULSE_CHECK:SP")
field(CALC, "((B=1)&&(A>2))?(A-3):(A+2)")
field(OUT, "$(P)MODE:SP PP")
}
These are now removed.