ZOOM Instrument Details
This page collects information that will be useful for the implementation of the new control system on ZOOM.
The ZOOM web page describes the background to the instrument. Additional material is also available on the ZOOM sharepoint. ZOOM is expected to have 36 motion axes.
The ZOOM shutter is due to open in February 2017 (see Zoom plan 28th May 2016).
ZOOM will use the IBEX control system.
The equipment listed below is to be used on ZOOM. Please add new information (e.g. new items of equipment, new notes, information about drivers, etc. to this table).
Manufacturer | Model | Type | Connection | Driver | Notes |
---|---|---|---|---|---|
ISIS | Fast Shutter | OMRON | see Fast Shutter note | ||
ISIS | Double Disc Chopper | CHOPPER | Ethernet/.NET | #170 | see ISIS Double Disk Chopper note |
JAWS | #179, #180 | see Jaws note | |||
Polariser, guide & collimation unit (PGC) | #1233 | see Polariser, Guide & Collimator note | |||
JAWS | #179, #180 | ||||
ISIS | Spin Flipper | #1234 | see SpinFlipper note | ||
JAWS | #179, #180 | ||||
Alignment Laser | see Alignment Laser note | ||||
JAWS | #179, #180 | ||||
JJ XRAY | 7-axis Sample Stack Manual | Sample Stack | #304, #1238 | see JJ X-Ray note | |
Translation (across beam) | Sample Stack | #1238 | see SampleStack note | ||
ISIS | Translation (along beam) | Sample Stack | #1238 | Driven by Beckhoff | |
ISIS | Two Tier - possibly | Sample Changer | see SampleChanger note | ||
Pneumatic Shutter | OMRON | see Pneumatic Shutter note | |||
ISIS | Tank Translation |
see Tank Translation note Driven by Beckhoff |
|||
In/Out Monitor | #267 | see Monitor note | |||
JAWS | #179, #180 | ||||
Detector Motion System (DMS) | #1236 | see Detector Motion System (DMS) note | |||
ISIS | DAE (2 or 3?) | Detector Electronics | Ethernet | #219 | see DAE note |
CAEN | HT | Detector HV Control | Ethernet | #214 | see CAEN HT note |
OMRON | PLC | Ethernet | FINS, #217 | see OMRON PLC note | |
Galil | DMC2280 | Motion Controller | Ethernet | EPICS | see Galil note |
Beckhoff | Motion Controller | TBC | see Beckhoff note | ||
Pfeiffer | TPG300 | ISIS VACUUM SYSTEM | RS232 | #218 | see Pfeiffer note |
Julabo | TBC | Water Bath | RS232 | #187, #188 | see Julabo note |
PSU | TBC | see Power Supply Unit note | |||
Oxford Instruments | ITC503 | Temp Controller | RS232 | see Oxford Instruments Temperature Controller note | |
Oxford Instruments | ILM200 series | Helium Level Meter | RS232 | EPICS | see Oxford Instruments Helium Level Meter note |
Eurotherm | All models at ISIS | Temp Controller | RS232 | EPICS | see Eurotherm note |
Eurotherm | Nanodac | Temp Controller | Ethernet | see Eurotherm note | |
Thurlby | EX355P | DC Power Supply | RS232 | #156 | see Thurlby note |
KEPCO | TBC | Bi-Polar Power Supply | RS232 | #189 | see KEPCO note |
Tektronix | MSO 4104B | Oscilloscope | Ethernet | #234 | see Tektronix note |
Tektronix | AFG 3022B | Function Generator | Ethernet | #237 | see Tektronix note |
PI | Rotation Stage | Nano-positioning Rotation Stage | RS232 | see Physik Instrument note | |
Bio-Logic | Stopped Flow Cell | RS232 | see BioLogic note | ||
17T Cryomag | Super conducting magnet | RS232 | |||
Oxford Instruments | 7.5T Magnet | Super conducting magnet | RS232 | see 7.5T Magnet note | |
Scientific Magnetics | 3 Axis Super conducting magnet & VTI | RS232 | see Scientific Magnetics note | ||
Lakeshore | All models at ISIS | TBC | see Lakeshore note | ||
Syringe Pumps | RS232 | see Syringe Pumps note | |||
see Hitachi note | |||||
TS-Haake | Water Bath | RS232 | see Thermo Scientific (Haake) note | ||
Huber | Sample Stack | RS232 | see Huber note | ||
Thar | Pressure Cell | TBC | see Thar note | ||
Goudsmit | 1T Magnet | Magnet | TBC | see Goudsmit note | |
Anton Paar | Rheometer | see Pfeiffer note | |||
ISIS | Couette Cell | see ISIS Couette Cell note | |||
McLennan | Motion Controller | RS232 | see McLennan note | ||
T-Jump Cell | RS232 | see T-JumpCell note | |||
Dynamic Light Scattering | DLS | TBC | see Dynamic Light Scattering (DLS) note | ||
Raman Spectroscopy | TBC | see Raman Spectroscopy note | |||
Linkam | RS232 | see Linkam note | |||
Keithley | All models in use at ISIS | RS232, USB | see Keithley note | ||
Closed Cycle Refrigerator | via Eurotherm? | see CCR note |
Location: Front End
Due: Day 1
As used on: SANS2D
ISIS Mk3 Chopper
Location: Front End
Due: Day 1
As used on: SANS2D
Location: Front End Vacuum Tank
Due: Day 1
As used on: Many instruments
Testing Summer 2015
Location: Front End Vacuum Tank
Due: Day 1
1 horizontal motion axis controlling four 4m evacuated tubes
Location: Fixed Collimation
Due: Day 1
4m evacuated tube & Spin-flipper unit
Spin-flipper will be controlled by 2 Kepco Power Supplies
Location: Blockhouse
Due: Day 1
Single in/out axis
No control of the alignment laser is required, other than the ability to move it in/out of the beam. It can treated like a monitor.
Location: Blockhouse
Due: Day 1
7-axis Sample Stack Manual
See also LARMOR
Location: Blockhouse
Due: Day 1
The JJ X-Ray sample stack will sit on rails to allow the entire sample stack to be translated back & forth along the beam. The rails are not perfectly straight, so there needs to be an axis allowing motion perpendicular to the rails to correct for any slight misalignment in the rails. In other words, there are two axes for wholesale motion of the sample stack (in addition to the 7 internal axes of the sample stack itself).
- Across beam (i.e. perpendicular to the rails): Alignment stage for reproducibility.
- Along beam (i.e. along the rails): Monitoring only, no control required.
See ZOOM_Sample_Stack_Schematic - The axis setup is described here
Location: Blockhouse
Due: Day 1
As used on: SANS2D
Location: Blockhouse
Due: Day 1
The tank will be moved by a motor connected to a Beckhoff controller.
Monitoring only, no control required.
Location: Tank
Due: Day 1
In/Out positioning - c.f. LARMOR, IMAT,others
Location: Tank
Due: Day 1
7 axes consisting of:
- Baffle
- Detector translation
- Strip Beam Stop
- 2x Disk Beam stop - x and y movement (total: 4 axes)
Location: Screened Room
Due: Day 1
As used on: Many instruments
Location: Screened Room
As used on: LARMOR
Location: TBC
As used on: LARMOR, IMAT
A full memory map is available
There are up to three functions for the PLC(s) - exactly which are to be included in the computing control is TBC. Current expectation is that the PLC will control:
- "Fast Shutter" (located at the front end of the beamline). SANS2D has a similar shutter.
- "Pneumatic Shutter" (located in the blockhouse). SANS2D has a similar shutter.
- Pfeiffer TPG 300 pressure gauges
Location: Blockhouse x 1, Mezzanine x 4
Due: Day 1
As used on: Many instruments
There are at present 39 axes to be controlled via Galil
Location: TBC
As used on: IMAT
The Beckhoff controller will control two axes:
- the motion of the JJ X-ray sample stack along the rails see SampleStack
- the motion of the tank (enclosing the detectors & detector motion system).
IBEX is NOT required to actually control these two axes (that will be done independently). IBEX is required to monitor the locations reported by the Beckhoff system - a read only driver will be required.
Location: TBC - alongside PLCs
Due: Day 1
As used on: LARMOR, IMAT
Location: TBC
Due: Day 1
As used on: LARMOR
Location: TBC
Due: Day 1
This is to control a magnet which will be linked to the interlocks, but there are no details at present
Model: ITC503
Location: TBC
As used on: LARMOR
Model: ILM200 series
As used on: LARMOR
Model: all models at ISIS
Due: Day 1
Location: TBC
As used on: LARMOR
Note: ZOOM may also use a Eurotherm Nanodac to monitor detector temperatures.
Location: TBC
As used on: LARMOR
Location: TBC
As used on: LARMOR
Location: TBC
As used on: LARMOR
- Model: Oscilloscope
- Model: Function Generator
Location: TBC
As used on: LARMOR
Location: Sample Area
Due: Day 1
Same as used on: SANS2D/LARMOR, translations done via sample stack
Model: Nano-positioning Rotation Stage
Location: TBC
PI Software, EPICS driver
As used on: LARMOR
Model: Stopped Flow Cell
Location: TBC
As used on: LARMOR
Model: 3 Axis Super conducting magnet & VTI
Location: TBC
As used on: LARMOR
Model: all models at ISIS
Location: TBC
As used on: LARMOR
Model: all models at ISIS
Location: TBC
As used on: LARMOR
Hitachi L-7100 HPLC pump (no longer supported at ISIS). Can't find L-7100 on Hitachi web-site (may be obsolete). Check existing SECI VI for logic and manual: both VI and manual are located here: C:\LabVIEW Modules\Drivers\Hitachi L-7100
.
- Update (27-06-2019): Hitachi pumps are no longer used. No longer any need to support them. See #3780.
Model: Water bath
Location: TBC
As used on: LARMOR
Model: Sample Stack
As used on: SANS2D
Location: TBC
Model: Pressure Cell
Location: TBC
As used on: SANS2D, LOQ
Model: 1T Magnet
Location: TBC
As used on: SANS2D, LOQ
Model: Rheometer
Location: TBC
As used on: SANS2D
Currently controlled from a separate PC
Location: TBC
As used on LOQ
Location: TBC
Due: Day 1
As used on: Many instruments
Location: TBC
As used on: LOQ
Location: TBC
As used on: SANS2D
There is an interaction with a LabVIEW function that ought to be reproduced.
Location: TBC
As used on: INTER
This may not have an existing interface, and may not need one
Location: TBC
There are VIs for this
Model: all models in use at ISIS
Location: TBC
There are VIs for this
Model: TBC
Location: TBC
Details of Closed-Cycle Refrigerators at ISIS.
Model: 7.5T Magnet